§ 4.10.50 — Standards For Residential Development
Municipal Code of the City of Corvallis, Oregon (Codified through Ordinance No. 2026-31, enacted October 19, 2026. (Supp. No. 70, Update 2)) · Corvallis Land Development Code § 4.10.50
Corpus is an independent public-information project, not the official City of Corvallis website. Stable reference: corpuslaw.us/code/02f3ff9b-1da7-44e2-bf49-20985a1cc3ec
Section 4.10.50 - Standards For Residential Development.
4.10.50.01 Applicability. All new Residential Building Types for which a valid permit application has been submitted must comply with Sections 4.10.50.02 through 4.10.50.04. Residential development consisting of multi-dwellings (5 units or greater) for which a valid permit application has been submitted must comply with Sections 4.10.50.02 through 4.10.50.04 and the additional requirements of Section 4.10.50.05. Exceptions: a. Accessory Dwelling Units b. Cottage Cluster (see Section 4.10.55 for applicable Pedestrian Oriented Design Standards) c. Manufactured Dwelling Facility (see Chapter 4.8 - Manufactured Dwelling Facility Standards) 4.10.50.02 Building Orientation, Entrances, and Facades Adjacent to Pedestrian Areas. a. Orientation of Dwellings - All buildings must be oriented to existing or proposed public or private streets, as follows: At least one dwelling within the building has its primary entrance facing the street or the primary entrance is directly accessed from a public street right-of-way or private street tract by a sidewalk or multi-use path less than 100 feet long (distance measured along the centerline of the path from a public street right-of-way or private street tract to the primary entrance). The primary dwelling unit entrance must open directly to the outside and not require passage through a garage or carport to gain access to the dwelling. Where multiple buildings are located on the same Development Site, this standard is applies only to building(s) located within the required maximum front yard setback. b. Windows and Doors - Any facade facing a street, sidewalk, or multi-use path must include windows or doors, or a combination of windows and doors, with a total area that is equal to or greater than 15 percent of the area of the façade. This provision includes garage facades. Garage doors must not be included as a door for purposes of this requirement. However, windows provided within a garage door can be included when calculating the window percentage requirement. Gabled areas need not be included in the base wall calculation when determining this minimum 15 percent requirement. 4.10.50.03 Maximum Widths of Street-facing Garages, Placement, and Materials. a. Maximum Widths of Street-facing Garages 1. Lots ≥ 50 Ft. in Width - For buildings with front-loaded garages, the width of the garage wall facing the street must be no more than 50 percent of the width of the building's street-facing facade. Front-loaded garages are attached garages with entrances facing the same street as the primary building entrance. Additionally, the term garage wall pertains to the whole wall and not just the doors. See Figure 4.10-1A - Unacceptable Width of Street-facing Garage on a Lot ≥50 feet and Figure 4.10-1B - Acceptable Width of Street-facing Garage on a Lot ≥ 50 feet [image omitted; see the official code] Figure 4.10-1A - Unacceptable Width of Street-facing Garage on a Lot >50 feet Wide [image omitted; see the official code] Figure 4.10-1B - Acceptable Width of Street-facing Garage on a Lot >50 feet Wide 2. Lots < 50 Ft. in Width - For buildings with front-loaded garages, the area of the garage wall facing the street must be no more than 50 percent of the area of the building's street-facing facade. Front-loaded garages are attached garages with entrances facing the same street as the building's primary entrance. The area is measured in sq. feet and, with the exception of gabled areas and second stories, the entire facade of the garage is measured. The interior of the garage determines the width of the garage facade, not just the garage doors. See Figure 4.10-2A - Unacceptable Street-facing Garage Area and Figure 4.10-2B - Acceptable Street-facing Garage Area. [image omitted; see the official code] Figure 4.10-2A - Unacceptable Street-facing Garage Façade Area [image omitted; see the official code] Figure 4.10-2B - Acceptable Street-facing Garage Façade Area 3. Exception - Where the street-facing facade of a building is less than 24 feet wide, the garage wall facing the street may be up to 12 feet wide if the garage meets one of the following: a) Interior Living Area above the Garage - The living area is not set back more than four feet from the street-facing garage wall; or b) Covered Balcony - A covered balcony above the garage is: 1) At least the same width as the street-facing garage wall; 2) At least six feet deep; and 3) Accessible from the interior living area of the building. b. Garage Placement - Garages must be placed only as indicated in the options below. The applicant must indicate the proposed option(s) on plans submitted for building permits. Additionally, measurements may be taken from the second floor of homes, provided the second floor spans across the entire garage. As used below, the term "front wall of the building" means the living space wall that is closest and roughly parallel to the street frontage that the garage is oriented towards. A front porch, bay window, or other projection or architectural feature does not constitute a living space wall. Garage Placement Options - 1. Street Accessed Garage with Four-feet Recess - Vehicular entrances face the street and are recessed at least four feet from the front wall of the building as shown in Figure 4.10-3 - Garage Facing Street and Recessed at Least Four Ft [image omitted; see the official code] Figure 4.10-3 - Garage Facing Street and Recessed at Least Four Ft.; and Figure 4.10-4 - Garage with Alley Access 2. Side or Rear Accessed Garage- Vehicular entrances are accessed from and oriented towards a rear or side alley or driveway, and not a street, as shown in Figure 4.10-4 - Garage with Alley Access. Garage setbacks from alleys are outlined in Section 4.0.60.j of Chapter 4.0 Improvements Required with Development. Any garage wall facing a street must provide a minimum area of 15 percent windows and/or doors. 3. Garage Access Diagonal to the Street - Vehicular entrances are oriented diagonally to the street, as shown in Figure 4.10-5 - Garage Access Diagonal to the Street, below. The garage wall facing the street must include a minimum area of 15 percent windows and/or doors. To determine whether the portion of the garage that faces the street complies with Section 4.10.50.03.a, the width of the front garage wall is measured as the length of the leg of a right triangle parallel to the street, where the hypotenuse of the triangle is the front of the garage. [image omitted; see the official code] Figure 4.10-5 - Garage Access Diagonal to the Street 4. Basement Garage - Vehicular entrances face the street and garages are located beneath the main floor and front door entrance to the building, provided the garage entrances are flush with or set behind the front wall of the building, as shown in Figure 4.10-6 Basement Garage, below. This option addresses the basement garage scenario in hillside areas. [image omitted; see the official code] Figure 4.10-6 - Basement Garage 5. Flush Garage with Porch - Vehicular entrances face the street and are flush with or recessed from the front wall of the building, and a front porch is provided with minimum dimensions of 6 feet by 10 feet (60 sq. feet). A minimum of 60 percent of the porch must be covered to provide weather protection. 6. Flush or Recessed Single Car Garage - Vehicular entrances face the street and are flush with or recessed from the front wall of the building, and the garage is a single-car garage that is a maximum of 12 feet wide. These options are shown below in Figure 4.10-7 - Single Car Garage Access Recessed from Front Wall of Dwelling and in Figure 4.10-8 - Single Car Garage Flush from Front Wall of Dwelling. [image omitted; see the official code] Figure 4.10-7 - Single Car Garage Recessed from Front Wall of Dwelling [image omitted; see the official code] Figure 4.10-8 - Single Car Garage Flush with Front Wall of Dwelling 7. Narrow Lot (less than 40 feet width) Facing Street - Vehicular entrances face the street and the garage portion of the building is recessed a minimum of 2 feet from the portion of the building nearest the street that is designed for human occupancy (includes enclosed rooms, porches, balconies, etc.) and the width of the garage portion of the building is equal to or less than 50% of the lot width. c. Garage Materials - When provided, garages must be constructed of the same building materials as the primary building. 4.10.50.04 Menus for Building Articulation and Design Variety. a. Building and Roof Articulation - Street-facing building elevations with a length exceeding 40 feet must incorporate design features to preclude large expanses of uninterrupted building surfaces. Along the face(s) of a structure oriented toward a public or private street, such features must occur at least every 40 feet in the horizontal dimension. In addition, each story (as the term "story" is defined in the Oregon Residential Specialty Code) is required to include at least one such feature. For townhomes, this requirement applies where attached units exceed a length of 40 feet and the standard is satisfied by applying the articulation and design features to their combined length. At least two of the following three choices must be provided on the street-facing building elevations: 1. Off-sets or breaks in roof elevation of three feet or more in height, or cornices two feet or more in height. 2. Recesses, such as enclosed floor area, decks, patios, courtyards, entrances, etc., with a minimum depth of two feet and minimum length of four feet if combined with a change in exterior siding using one or more of the materials listed below in Section 4.10.50.04.b.3., or with a minimum depth of four feet and minimum length of eight feet if not combined with a change in exterior siding materials. 3. Extensions/projections, such as enclosed floor area, porches, bay windows, decks, entrances, etc., that have a minimum depth of two feet and minimum length of four feet if combined with a change in exterior siding using one or more of the materials listed below in Section 4.10.50.04.b.3, or with a minimum depth of four feet and minimum length of eight feet if not combined with a change in exterior siding materials. b. Design Variety Menu - Each building must incorporate a minimum of three of the following eight building design features. Building design features are required on the street facing façade for development on an interior lot, and both street facing facades for development on a corner lot. 1. Roof Pitch - A minimum 6:12 roof pitch with at least a six-inch overhang. 2. Eaves - Eaves with a minimum 18-in. overhang. 3. Building Materials - At least two different types of building materials including but not limited to stucco and wood, brick and stone, etc. Alternatively, a minimum of two different patterns of the same building material, such as scalloped wood and lap siding, etc., on facades facing streets. These requirements are exclusive of foundations and roofs and pertain only to the walls of a structure. 4. Trim - A minimum of 2.25-in. trim or recess around windows and doors that face the street. 5. Increased Windows - A minimum area of 20 percent windows and/or doors on facades facing streets, sidewalks, and multi-use paths. This provision includes garage facades. Gabled areas need not be included in the base wall calculation when determining this minimum 20 percent calculation. 6. Architectural Features - At least one architectural feature included on dwelling facades that face the street. Architectural features are defined as bay windows, covered porches greater than 60 sq. feet in size, balconies above the 1st floor, dormers related to living space, or habitable cupolas. 7. Architectural Details - Architectural details used consistently on dwelling facades. Architectural details are defined as exposed rafter or beam ends, eave brackets, windows with grids or divided lights, or pergolas/trellis work integrated into building facades. 8. Elevated Finished Floor - An elevated finished floor a minimum of two feet above the grade of the nearest street sidewalk or streetside multi-use path. 4.10.50.05 Pedestrian Circulation and Site Design Standards for Multi-Dwellings. a. Applicability - The following additional pedestrian circulation and site design standards apply to all residential developments with five or more dwelling units. b. Standards - 1. Connectivity - The internal sidewalk system must connect all abutting streets to primary building entrances. The internal sidewalk system must connect all buildings on site, and connect the dwelling units to vehicle and bicycle parking areas, refuse areas, and all recreational facility and common areas on or abutting the property. The internal sidewalk system must connect to abutting public sidewalks, multi-use paths and other pedestrian connections, and be stubbed towards any future phases on the subject property. 2. Sidewalk and Building Separation - Internal sidewalks must be separated a minimum of five feet from dwellings, measured from the sidewalk edge closest to the dwelling unit. This requirement does not apply to the following: a) Sidewalks along public or private streets used to meet building orientation standards; or b) Mixed use buildings and multi-family densities exceeding 30 units per acre. 3. Sidewalk Surface Treatment - Public internal sidewalks must be concrete and must be at least five feet wide. Private internal sidewalks are required to be concrete, or masonry; and must be at least five feet wide. All materials used for sidewalks must meet City Engineering standards. 4. Crossings - Where internal sidewalks cross a vehicular circulation area or parking aisle, they must be clearly marked with contrasting paving materials. 5. Sidewalk and Vehicle Circulation Separation - The following buffering standards apply to dwelling units built within eight feet of ground level: a) Driveways and parking lots must be separated from windowed walls by at least eight feet; sidewalks and multi-use paths must be separated by at least five feet b) Driveways and uncovered parking spaces must be separated from doorways by at least five feet 6. Safety Adjacent to Vehicular Areas - Where internal sidewalks parallel and abut a vehicular circulation area, sidewalks must be raised a minimum of six in., or must be separated from the vehicular circulation area by a minimum six-in. raised curb. In addition, a landscaping strip at least five feet wide, or wheel stops with landscaping strips at least four feet wide, must be provided. 7. Building Separation - The minimum distance between multi-dwellings must be 10 feet. 8. Percentage of Frontage - Residential Mixed Use (RMU) and Commercial Mixed Use (CMU) Zones: See the minimum Frontage Occupation established for each Zone. All other zones: On sites with 100 feet or more of public or private street frontage, at least 50 percent of the street frontage width must be occupied by one or more buildings placed within the maximum front yard setback established for the Zone. For sites with less than 100 feet of public or private street frontage, at least 40 percent of the street frontage width must be occupied by buildings placed within the maximum front yard setback established for the Zone. Exception: This requirement does not apply to buildings on lots with a rear lot line length that is 50 percent or less of the length of the front lot line.
(Ord. No. 2012-16, eff. 12-13-2012; Ord. No. 2012-18, eff. 12-13-2012; Ord. No. 2014-18, eff. 12-11-2014; Ord. No. 2014-19, eff. 12-11-2014; Ord. No. 2020-04, eff. 3-3-2020; Ord. No. 2021-22, eff. 11-24-2021; Ord. No. 2022-12, eff. 6-1-2022; Ord. No. 2023-01, eff. 2-8-2023)
Ask a question about Corvallis law
Corpus searches the Corvallis sections it holds and shows the ones that match, with their citations. Free, no sign-in.