§ 4.10.70 — Standards For Commercial, Industrial, and Civic Development
Municipal Code of the City of Corvallis, Oregon (Codified through Ordinance No. 2026-31, enacted October 19, 2026. (Supp. No. 70, Update 2)) · Corvallis Land Development Code § 4.10.70
Corpus is an independent public-information project, not the official City of Corvallis website. Stable reference: corpuslaw.us/code/8c131850-dfab-4b76-ba88-cb167cf1f195
Section 4.10.70 - Standards For Commercial, Industrial, and Civic Development.
4.10.70.01 Applicability. a. All new commercial, industrial, and civic building types and associated features, such as parking lots, within all zones that refer to Section 4.10.70 must comply with Sections 4.10.70.02 through 4.10.70.05. Buildings associated with stand alone Automotive and Equipment - Car Wash, Fuel Sales, and Wholesale, Storage, and Distribution - Mini Warehouses use types are not required to comply with these Sections. b. Independent or cumulative expansions of a commercial, industrial, or civic structure in existence and in compliance with this Code on December 31, 2006, or constructed after December 31, 2006, pursuant to a valid Conceptual or Detailed Development Plan approved on or before December 31, 2006, are not required to comply with this section provided that: 1. The expansion adds floor area of 500 square feet or less; or 2. The expansion adds floor area of 3,000 square feet or less and is equivalent to 20 percent or less of the existing structure's gross floor area. c. Independent or cumulative expansions of a commercial, industrial, or civic structure in existence and in compliance with the Code on December 31, 2006, or constructed after December 31, 2006, pursuant to a valid Conceptual or Detailed Development Plan approved on or before December 31, 2006, must comply with the requirements of Sections 4.10.70.02 through 4.10.70.05, subject to the provisions in "d," below, that allow choices among some standards, provided that: 1. The expansion adds floor area of more than 3,000 square feet; or 2. The expansion adds floor area of more than 500 square feet and is equivalent to more than 20 percent of the existing structure's gross floor area. d. Pedestrian oriented design requirements for commercial, industrial, or civic structure expansions identified in Section 4.10.70.01.c, above, are as follows: 1. Applicants must choose at least four standards from Sections 4.10.70.02 - Building Orientation and 4.10.70.03 - Pedestrian Circulation Standards, with a minimum of one standard from each. This criterion does not apply if the expansion/enlargement is an upper story addition only. If the expansion/enlargement is for space not open to customers or to the public, applicants must choose only one standard from Section 4.10.70.02 and two standards from Section 4.10.70.03. 2. New parking must comply with the Vehicle Circulation and Design Standards in Sections 4.10.70.04.a.2 and 4.10.70.04.b. For new drive-throughs, Section 4.10.70.04.c applies. 3. Applicants must choose the option in Section 4.10.70.05.b.2.a or the option in Section 4.10.70.05.b.2.b. 4. Applicants must choose at least two of the five standards from Section 4.10.70.05.b.3.a through 4.10.70.05.b.3.e. If the expansion/enlargement is for space not open to customers or to the public, applicants must choose only one standard from Section 4.10.70.05.b.3.a through 4.10.70.05.b.3.e. e. The required standards applicable to expansions must be applied either to the portion of the building being expanded, or in equal proportion to portions of the original building not in compliance with respect to the standard. For example, where windows may be required, but the security of a proposed storage room is needed, the applicant may install windows on other portions of the building not in compliance with the window provisions to satisfy the requirements. f. Accessory Structures not open to customers or the public, and modular classroom buildings on school grounds, are not required to comply with this section provided that: 1. The Accessory Structure is not located between the primary building and the street to which that building is oriented; and either a) The building is 500 square feet or less in size; or b) The building is 3,000 square feet or less in size and is equivalent to 20 percent or less of the primary structure's gross floor area. 4.10.70.02 Building Orientation. All buildings must be oriented, as outlined in this Section, to existing or proposed public or private streets. See Chapter 4.0 Improvements Required with Development for public and private street standards. The building orientation standard is met when all of the following criteria are met: a. Street Frontage Setback - Residential Mixed Use (RMU) Zones and Commercial Mixed Use (CMU) Zones: See the minimum Frontage Occupation established in each zone chapter. All other zones that include a Maximum Front Yard Setback standard: At least 50 percent of the building's linear frontage is located within the maximum setback established for the zone for structures that have street frontage. Expansion of a structure existing prior to December 31, 2006, and in conformance with the Code on that date is deemed to meet this criterion, provided the area of expansion is between the street and the existing building frontage. b. Entrances - All building sides that face an adjacent public or private street must include at least one primary pedestrian entrance oriented to a public pedestrian facility such as the adjacent public sidewalk and be accessible to people with mobility disabilities. When the Development Site contains frontage on more than one street, building corner entrances at an angle of up to 45 degrees, from the largest of the two adjacent streets, may be substituted for separate entrances on adjacent streets. If the building does not have frontage along an adjacent street, direct pedestrian access to the street may be achieved by a sidewalk or courtyard connecting to a street no farther than 100 feet from the building's pedestrian entrance (distance measured along the centerline of the sidewalk or over the "hard-surfaced" portion of the courtyard from a public street right-of-way or private street tract). Examples of these requirements are shown below in Figure 4.10-11 - Site Development Element Locations. Buildings of less than 3,000 sq. feet fronting on only one street may provide the primary pedestrian entrance on the side of the building in lieu of the front, if a sidewalk or courtyard provides a direct, "hard-surfaced" pedestrian connection of less than 50 feet between the entrance and the street (distance measured along the centerline of the sidewalk or over the "hard-surfaced" portion of the courtyard from a public street right-of-way or private street tract). [image omitted; see the official code] Figure 4.10-11 - Site Development Element Locations 4.10.70.03 Pedestrian Circulation Standards. a. Requirements for New Development and Options for Expansions of a Commercial, Industrial, or Civic Structure, Consistent with Section 4.10.70.01.c - 1. Continuous Internal Sidewalks - A continuous internal sidewalk, including associated necessary sidewalk crossings, no less than five feet wide, must be provided from public sidewalks or rights-of-way to all primary pedestrian entrances, and between primary pedestrian entrances of all buildings, as shown in Figure 4.10-11 - Site Development Element Locations. Sidewalks must be direct and convenient and form a network of walking routes. 2. Sidewalks along Building Walls - Sidewalks no less than five feet wide must be provided along the full length of building walls featuring a primary pedestrian entrance and along any wall parallel to and abutting parking areas larger than eight parking spaces, except in situations where the sidewalk would not provide connectivity between an entrance and parking area. These elements are noted in Figure 4.10-11 - Site Development Element Locations. 3. Separation and Distinction from Driving Surfaces - Where any internal sidewalk is parallel to and abuts a vehicular circulation or parking area, the sidewalk must be raised and separated from the vehicular circulation or parking area by a raised curb at least six in. in height. In addition to this requirement, a landscaping strip at least five feet wide, or wheel stops with landscaping strips at least four feet wide, are strongly encouraged to enhance the separation of vehicular from pedestrian facilities. 4. Sidewalk Treatment - Internal sidewalks must be concrete and at least five feet wide. 5. Crossings - Where any internal sidewalk crosses an internal street, driveway, or parking aisle, the sidewalk must be clearly marked and constructed with paving materials that contrast with the intersecting vehicle driving surface. Additional use of other measures to clearly mark a crossing, such as an elevation change, speed humps, or striping, is encouraged. 6. Connection to Adjacent Properties or Streets - In addition to the sidewalk connections required by the block development standards in Chapter 4.0 Improvements Required with Development, sidewalk connections shall be provided between internal sidewalk networks and all adjacent planned streets, sidewalks, and multi-use paths. Multi-use paths shall be connected with adjacent multi-use paths, sidewalks, and/or bike lanes. Where appropriate, such connections shall also be provided to adjacent residential properties. b. Additional Requirement for New Development and Additional List of Options for Expansions of a Commercial, Industrial, or Civic Structure, Consistent with Section 4.10.70.01.d.1 - Except in the Commercial Mixed Use (CMU) and Residential Mixed Use (RMU) Zones, an applicant proposing new Commercial, Industrial, or Civic development must include one of the following six design options. Applicants may add this list of choices to those presented in Section 4.10.70.03.a to obtain a larger list of options, to comply with the requirements of Section 4.10.70.01.d.1. Design Options:: 1. Curb Cut Consolidation - Removal of at least one existing Curb Cut through outright removal or access consolidation, such that the net number of Curb Cuts for the Development Site is at least one fewer than prior existing conditions. 2. Increased Landscape Buffer for Existing and New Vehicle Parking Areas - Construction or expansion of a landscape buffer for a parking, loading, and vehicle maneuvering area that exceeds the minimum width required in Section 4.2.40.a. The constructed or expanded landscape buffer must be a minimum of 20 feet wide for its full length. 3. Photovoltaic Solar Installation for Surface Parking Areas Less Than ½ Acre - The Development Site contains less than ½ acre of Surface Parking Area, and the applicant installs photovoltaic solar panels with a generation capacity of at least 0.5 kilowatt per provided parking space on the Development Site. 4. Covered Walkways - Installation of weather protection resulting in covered pedestrian walkways between and around all buildings and between the primary building and adjacent public pedestrian facilities. This option does not require covered pedestrian walkways along any facade without a pedestrian entrance. 5. Street Median Improvements and Waiver of Remonstrance - Where development is proposed on property adjacent to existing five-lane arterial streets or highways, the applicant and owner record a signed and notarized letter with the Benton County Clerk stating the owner and future owners of the Development Site agree not to oppose construction of a future median or pedestrian refuge. 6. Covered Bicycle Parking - The applicant provides covering (weather protection) for 100 percent of the bicycle parking spaces provided with development. 4.10.70.04 Vehicle Circulation and Design Standards. a. Parking Lots - 1. Off-street parking and vehicular circulation must be placed to the rear of buildings. The Applicant may seek and the Director may approve an exception to this standard when the Director finds that parking cannot be located to the rear of the building due to other requirements of this Code or unusual site constraints, both of which are defined in the following paragraph, the amount of parking and vehicle circulation that cannot be accommodated to the rear of the building may be provided only to the side of the building. Where allowed by the underlying zone, outdoor vehicle display lots for sale of autos, noncommercial trucks, motorcycles, trailers with less than 10,000 lbs. gross cargo weight, motor homes, and boats may be located adjacent to streets. 2. Other requirements of this Code may include, but are not necessarily limited to, significant Natural Resource and Natural Hazard provisions in Chapter 2.11 - Floodplain Development Permit, Chapter 4.2 - Landscaping, Buffering, Screening, and Lighting, Chapter 4.5 - Floodplain Provisions, Chapter 4.12 - Significant Vegetation Protection Provisions, Chapter 4.13 - Riparian Corridor and Wetland Provisions, and Chapter 4.14 - Landslide Hazard and Hillside Development Provisions; and Chapter 4.1 - Parking, Loading, and Access Requirements. Unusual site constraints may include parcels fronting more than two streets, irregular lot configuration, weak foundation soils, or other physical site factors that constrain development when considered with Building Code requirements. b. Corner Parcels - Parking areas shall not be located within 30 feet of a roadway intersection, as measured from the center of the curb radius to the edge of the parking area's curb or wheel stop. c. Drive-through Facilities - Internal driveways are prohibited between buildings and streets to which the building entrances are oriented. Examples of correct and incorrect locations of these facilities are shown on the next page in Figure 4.10-12 - Drive-through Facilities. [image omitted; see the official code] Figure 4.10-12 Drive-through Facilities 4.10.70.05 Standards and Menus for Pedestrian Features and Design Variety. a. Pedestrian Amenities Standards 1. Weather Protection - a) General - Except as provided in "b," and "c," below, where new commercial and civic development is constructed immediately adjacent to (abutting) street sidewalks or pedestrian plazas, a minimum six-feet-wide, weather-protected area, protected by such elements as awnings or canopies, shall be provided and maintained along at least 80 percent of any building wall immediately adjacent to the sidewalks and/or pedestrian plazas. An additional requirement shall include a minimum eight-feet and maximum twelve-feet vertical clearance between the sidewalk and the lowest portion of the weather protection. The minimum vertical clearance shall be nine feet for balconies. These requirements are shown below in Figure 4.10-13 - Weather Protection. [image omitted; see the official code] Figure 4.10-13 - Weather Protection b) Commercial Mixed Use 3 Zone - When subject to the standards in this chapter per Section 4.10.70.01, development on buildings abutting street sidewalks and pedestrian plazas in the Commercial Mixed Use 3 (CMU-3) Zone must provide weather protection consistent with the locational and dimensional standards in "a," above, when: 1) Expansion or improvement costs exceed 50% of the real market value of the property according to the Benton County Assessor's office; and 2) The building does not meet the exemption provisions in "c," below. c) General Commercial Zone - Weather protection in accordance with "a," above, is required only at street-oriented entrances. d) Designated Historic Resources - Development on Designated Historic Resources are subject to the provisions in Chapter 2.9 - Historic Preservation Provisions and exempt from the requirements in "a" through "c," above. This default to Chapter 2.9 and exemption from "a" through "c," above, applies whether or not weather protection such as awnings or canopies is proposed. 2. Pedestrian Amenity Requirements - Except in the Commercial Mixed Use (CMU), Residential Mixed Use (RMU), and General Commercial (GC) Zones, all new development and substantial improvements must provide pedestrian amenities as defined by this Section. The number of pedestrian amenities provided must comply with the following sliding scale: Size of Structure or Substantial Improvement | Number of Amenities < 5,000 sq. feet | 1 5,001—10,000 sq. feet | 2 10,001—50,000 sq. feet | 3 > 50,000 sq. feet | 4 3. Acceptable Pedestrian Amenities - Acceptable pedestrian amenities include the items listed below, some of which are shown in Figure 4.10-14 - Pedestrian Amenities: a) Sidewalks with ornamental treatments, such as brick pavers, or sidewalks 50 percent wider than required by this Code; b) Sidewalk planters with benches and public outdoor seating; c) Significant public art, such as sculpture, fountain, clock, mural, etc.; d) Mini parks or plazas that provide a minimum usable area of 300 sq. feet; and e) Street trees of a caliper 50 percent wider than required by this Code. This approach may include preservation of healthy mature trees adjacent to the street sidewalk. 4. Accessibility of Pedestrian Amenities - Pedestrian amenities must be visible and accessible to the general public from an improved street. Access to pedestrian amenities must be provided via a public right-of-way or a public access easement. [image omitted; see the official code] Figure 4.10-14 - Pedestrian Amenities b. Design Standards and Design Variety Menus 1. Loading/Service Facilities - Loading and service areas such as trash enclosures must be located and screened consistent with Section 4.2.40.01 - Trash Dumpsters, Mechanical Equipment, and Outdoor Storage Areas. To minimize conflicts with public pedestrian areas, facilities must also be located to the back or sides of buildings, or in alleys where available. In addition, all loading and service areas such as trash enclosures must be located and sized appropriately for servicing. 2. Windows - The provisions in this Section apply to placement and type of windows on street facing facades. a) Ground Floor Windows and Doors - Except for the General Commercial Zone, which is addressed in "c," below, a minimum of 60 percent of the length and 25 percent of the first 12 feet in height from the adjacent grade of any street-facing facade must contain windows and/or glass doors. For expansions or enlargements of existing buildings, the Director will grant an exception if the expansion/enlargement is for space neither adjacent to a street nor open to customers or the public. Additional requirements include the following: 1) Ground floor windows must be framed by bulkheads, piers, and sills such as are used in a recessed window. Ground floor windows must also have a Top Treatment such as a hood, awning, or a storefront cornice separating the ground floor from the second story. Alternatively, all ground floor windows shall provide a minimum three-in.-wide trim or recess. The Base Treatment standards under Section 4.10.70.05.b.3.d, below, and the Top Treatment standards under Section 4.10.70.05.b.3.e, below, shall be used as a guide for providing bulkheads and cornices that meet this standard. 2) Ground floor windows must have an opacity of less than 60 percent. 3) Ground floor windows must allow views from adjacent sidewalks into working areas, lobbies, or pedestrian entrances. The bottom of the window glazing must not exceed four feet above the adjacent exterior grade. b) Windows on Stories above Ground Floor - For stories above the ground floor, each street-facing facade must include at least 20 percent window coverage. c) General Commercial Zone - A minimum of 20 percent of the length and 10 percent of the ground-floor wall area of any street-facing façade shall contain windows and/or glass doors. d) Designated Historic Resource Exemption - Where development occurs on a Designated Historic Resource, that Resource is subject to the provisions of Chapter 2.9 - Historic Preservation Provisions, and is exempt from the window requirements in "a," through "c," above. This default to Chapter 2.9 and exemption from "a," through "c," above, applies whether or not windows are proposed. 3. Design Variety Menu - Each building must incorporate a minimum of three of the following five building design features. The applicant must indicate proposed options on plans submitted for building permits. While not all of the design features are required, the inclusion of as many as possible is strongly encouraged. a) Building Walls - Building walls in excess of 30 feet in length do not exceed a height/width ratio of 1:3 without a change in height of at least four feet, as addressed below in Figures 4.10-15A through C - Building Walls. [image omitted; see the official code] Figure 4.10-15A - Building Walls [image omitted; see the official code] Figure 4.10-15B - Building Walls [image omitted; see the official code] Figure 4.10-15C - Building Walls b) Maximum Wall Segments - All building wall segments on all sides of buildings are a maximum of 30 feet in length. Building wall segments are distinguished by architectural features including at least one of the following: columns, reveals, ribs or pilasters, piers, recesses, or extensions. The segment length may be increased to a maximum of 60 feet if the segment contains integral planters, public art, or permanent seating such as a seating wall, that conform to the accessibility standards in Section 4.10.70.05.a.4. c) Entrances - Primary building entrances are clearly defined by recess or projection, and framed by a sheltering element such as an awning, overhang, arcade, or portico. d) Base Treatments - A recognizable Base Treatment consisting of at least one of the following: 1) Thicker walls, such as a bulkhead, ledges, or sills as viewed from the exterior of the building; 2) Integrally textured materials such as stone, stucco, or other masonry; 3) Integrally colored and patterned materials such as smooth-finished stone or tile; 4) Lighter or darker colored materials, Mullions, or panels; 5) Detailing such as scoring, ribbing, moldings, or ornamentation; or 6) Planters integral to the building. e) Top Treatments - A recognizable Top Treatment consisting of at least one of the following: 1) Cornice treatments, other than colored stripes or bands that are integral to the building design. Materials such as stone, masonry, brick, wood, galvanized and painted metal, or other colored materials are used; 2) Sloping roof (4:12 or greater) with overhangs. Overhangs may be boxed with moldings such as Modillions, Dentils, or other moldings, as applicable; or contain brackets; or 3) Stepped parapets.
(Ord. No. 2012-16, eff. 12-13-2012; Ord. No. 2012-17, eff. 12-13-2012; Ord. No. 2012-18, eff. 12-13-2012; Ord. No. 2014-19, eff. 12-11-2014; Ord. No. 2022-06, eff. 3-17-2022; Ord. No. 2023-01, eff. 2-8-2023; Ord. No. 2023-19, § 40(Exh. A), eff. 6-30-2023)
Ask a question about Corvallis law
Corpus searches the Corvallis sections it holds and shows the ones that match, with their citations. Free, no sign-in.
