Section 4.5.100 - Standards in Partial Protection Floodway Fringe Areas.
In addition to the requirements of the underlying zone, the following standards apply to activities and Development in Partial Protection Floodway Fringe areas. These areas contain the portions of the Millrace, Willamette River, and Marys River 100-yr. Floodplain within the City Limits boundary, as of December 31, 2004; and specific portions of local Streams as noted on the Riparian Corridors and Wetlands Map. Where applicable state or federal regulations provide greater restrictions, such regulations apply. The applicant must obtain all necessary local, state, and federal approvals prior to the commencement of earth movement or construction in these areas. Except as provided in Sections 4.5.100.01 and 2.11.40, the placement of fill is prohibited within Partial Protection Floodway Fringe areas. 4.5.100.01 Excavation and Grading. a. Volumetric exchange: To compensate for the deposition of fill materials or construction of flood-proofed buildings within any portion of the 100-yr. Floodplain, an equal amount of material must be removed from the same property or Development Site to ensure that the available flood volume of the 100-yr. Floodplain is not reduced. Unless permitted in accordance with Section 4.5.80, no increase in Base Flood Elevation will be permitted. 1. Volumetric exchange is limited to the following areas: a. Floodway Fringe portions of the Mill Race and Willamette and Marys Rivers; and b. Floodway Fringe portions of other local streams, provided the area is designated as Partial Protection Floodplain on the Natural Hazards Map and at least one of the following is true: i. The development is nonresidential construction; or ii. The development is residential construction and the development is less than a Substantial Improvement; or iii. The development is residential on a site where the natural grade is such that, if flow-through design were used and the finished floor elevation were constructed at the Design Flood Elevation (DFE), the resulting foundation wall would not be deep enough to accommodate the required venting below base flood elevation; or iv. The development is a garage; or v. The development is a driveway or building access. 2. Volumetric exchange is required for flood-proofed buildings and structures within the Floodway Fringe but is not required for buildings constructed with Flow-through Design. 3. The volume of a stormwater detention facility necessary to accommodate the designed-for storm event will not count as an element of volumetric exchange. b. Material removed from the site may not be taken from Significant Natural Resource areas as mapped on the Corvallis Significant Vegetation Map and Riparian Corridors and Wetlands Map, and may only be removed consistent with all requirements of this Code and other applicable City policies; c. Areas of fill and excavation must be designed to accommodate floodwater flows and not create barriers to the flow of floodwater. Proposals to alter topography in the Floodplain must demonstrate that they will not result in alteration of hydrology or flow regimes that would cause erosion, ponding, new or increased drainage onto neighboring properties, or other problems; d. Dikes are prohibited in these areas; and e. The applicant must design any fill allowed to be placed within the Floodway Fringe such that it is stable under conditions of flooding, including rapid rise and rapid drawdown of floodwaters, prolonged inundation, and flood-related erosion and scour. 4.5.100.02 Parking Limitation - to Reduce Impervious Surface Area in the Floodplain. a. Where permitted, expansion, redevelopment, or Development of a parking lot containing four or more parking spaces within any portion of the Floodway Fringe is limited to 50 percent of the maximum amount of parking allowed per Chapter 4.1 - Parking, Loading, and Access Requirements, unless "1," or "2," below, is true. In Zones where the maximum amount of parking standard does not apply, all new parking must comply with "1" or "2" below. 1. Be constructed of appropriate pervious materials approved by the City Engineer; or 2. Be contained in a multi-story structured parking facility with at least 50 percent of the provided parking located above ground level and utilizing Flow-through Design. b. Compact Spaces - Where parking lots are permitted in the Floodway Fringe: 1. 50 percent of the parking spaces within new and redeveloped parking lots must be compact spaces; and 2. If existing parking lots within the Floodway Fringe are permitted to expand, per the provisions of this Chapter, all additional parking spaces created in the expanded parking lot must be compact spaces, until the 50 percent threshold in "1," above, is reached for the overall parking lot. c. Parking Lots - Parking lot design must allow for the entry and exit of floodwaters by incorporating voids within the curb and installing paving materials and landscaping at existing grade. 4.5.100.03 Adherence to Sections 4.5.110, 4.5.120, and 4.5.20.03. Development is required to adhere to the Construction standards in Section 4.5.110, Subdivision, Partition, and Property Line Adjustment standards in Section 4.5.120, and Minimum Assured Development Area (MADA) in Section 4.5.20.03.
(Ord. No. 2023-19, § 37(Exh. A), eff. 6-30-2023; Ord. No. 2025-31, §§ 2, 8(Exh. A), 7-21-2025)
Ask a question about Corvallis law
Corpus searches the Corvallis sections it holds and shows the ones that match, with their citations. Free, no sign-in.