§ 4.5.110 — Construction Standards Within the 100-yr. Floodplain
Municipal Code of the City of Corvallis, Oregon (Codified through Ordinance No. 2026-31, enacted October 19, 2026. (Supp. No. 70, Update 2)) · Corvallis Land Development Code § 4.5.110
Corpus is an independent public-information project, not the official City of Corvallis website. Stable reference: corpuslaw.us/code/e681a6c3-9cb9-448e-9aef-eebafd4a8c08
Section 4.5.110 - Construction Standards Within the 100-yr. Floodplain.
General Standards for All Construction - Development within the Floodway Fringe (Federal Flood Zones A, AH, A1-A30, AE, AO, and A99 on the Flood Insurance Rate Map), including residential and nonresidential buildings and structures and the public and private facilities serving these buildings and structures, must adhere to the following standards so as to minimize damage from flooding. Unless permitted in accordance with Section 4.5.80, no increase in Base Flood Elevation will be permitted. Although other types of construction are allowed by this Code, Flow-through Designs are preferable. The standards in Section 4.5.110.01 through Section 4.5.110.03, below, apply to all construction within the Floodway Fringe. Additional standards in Section 4.5.110.04 through Section 4.5.110.15, below, apply, for the specific types of development stated in those Sections. 4.5.110.01 [Permits.]. The applicant must obtain all necessary permits from those governmental agencies from which approval is required by federal or state law, including Section 404 of the Federal Water Pollution Control Act Amendments of 1972, 33 U.S.C. 1334, as amended. If obtaining such permits is a Condition of Approval for a land use application, such Condition of Approval must be satisfied prior to issuance of any construction permit. 4.5.110.02 [Permit Applications.]. All Land Division and Building Permit applications, including the placement of mobile and Manufactured Dwellings within Federal Flood Zones A, A1-A30, AE, AH, AO, and A99, will be reviewed for conformance with these standards. a. Be consistent with the need to minimize flood damage; b. Locate and construct utilities such as sewer, gas, electrical, and water systems to minimize or eliminate flood damage; c. Provide adequate drainage to reduce exposure to flood hazards; d. Design new and replacement water systems within flood-prone areas to minimize or eliminate infiltration of flood waters into the systems; and e. Design new and replacement sanitary sewer systems within flood-prone areas to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters. On-site waste disposal systems are not allowed. 4.5.110.03 Floodplain Protection Construction Standards. All New Construction and Substantial Improvements including nonhabitable enclosures must be designed to comply with the following: a. Structures must be adequately anchored to prevent flotation, collapse, or lateral movement of the structure resulting from Hydrodynamic and Hydrostatic Loads, including the effects of buoyancy during the 100-yr flood event; b. The Lowest Floor as defined in Section 1.6.40, including all electrical, mechanical, and ductwork must be elevated or watertight to the Design Flood Elevation (DFE); c. All building materials not elevated to the Design Flood Elevation (DFE) must be constructed with materials that resist, and methods that minimize, flood damages; and d. If a crawlspace is constructed, the crawlspace floor elevation must be at or above the elevation of the grade outside of the foundation or comply with Section 4.5.110.07. 4.5.110.04 Residential Construction. a. Lowest Floor - New Construction, conversion to, and Substantial Improvement (as defined in Chapter 1.6 - Definitions) of any residential structure, including mobile and Manufactured Dwellings, must have the Lowest Floor elevated at or above the Design Flood Elevation (DFE). In AO Federal Flood Zones, the Lowest Floor must be elevated a minimum of one ft. above the flood Depth Number or, in areas where the Depth Number is unknown, the Lowest Floor must be elevated a minimum of three ft. above the Highest Adjacent Grade. Lowest Floor includes basements, Habitable attached garages, electrical, heating, ventilation, air conditioning equipment, ductwork, plumbing, and other service facilities. See definition for Lowest Floor in Section 1.6.40. b. Flood Openings - Crawl spaces and non-habitable enclosed areas must have flood openings. All new construction and substantial improvements with fully enclosed areas below the lowest floor (excluding basements) are subject to the following requirements. Enclosed areas below the Base Flood Elevation, including crawl spaces must: a. Be designed to automatically equalize hydrostatic flood forces on walls by allowing for the entry and exit of floodwaters; b. Be used solely for parking, storage, or building access; c. Be certified by a registered professional engineer or architect or meet all of the following minimum criteria: i. A minimum of two openings on at least two sides of each enclosed area; ii. The total net area of non-engineered openings must not be less than one square inch for each square foot of enclosed area, where the enclosed area is measured on the exterior of the enclosure walls; iii. The bottom of all openings must be no higher than one foot above adjacent grade; iv. Openings may be equipped with screens, louvers, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. v. The design must comply with all additional and applicable higher standards for flood openings in the State of Oregon Residential Specialty Codes Section R322.2.2. 4.5.110.05 Manufactured Dwellings. In addition to the requirements in Section 4.5.110.04 for residential construction, all mobile and Manufactured Dwellings must comply with the following: a. Manufactured dwellings to be placed (new or replacement) or substantially improved that are supported on solid foundation walls must be constructed with flood openings that comply with section 4.5.110.04.b. Break-away skirting as defined by FEMA may be provided when not installed on solid foundation walls; b. The bottom of the longitudinal chassis frame beam must be at or above Base Flood Elevation; c. Manufactured dwellings to be placed (new or replacement) or substantially improved must be anchored to prevent flotation, collapse, and lateral movement during the base flood and be installed using methods and practices that minimize flood damage. Anchoring methods may include, but are not limited to, use of over-the-top or frame ties to ground anchors as approved by the Building Official (Reference FEMA's "Manufactured Home Installation in Flood Hazard Areas" guidebook for additional techniques). This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces, and; d. Electrical crossover connections must at or above Design Flood Elevation (DFE). 4.5.110.06 Nonhabitable Enclosures. Accessory buildings and fully enclosed nonhabitable areas below the Lowest Floor that are subject to flooding are prohibited, unless designed to automatically equalize Hydrostatic flood forces on exterior walls by allowing for the entry and exit of flood waters (fences and walls are not governed by this section, but are subject to the standards in Section 4.5.110.14). These accessory buildings and fully enclosed nonhabitable areas include nonhabitable attached or detached garages, provided they meet the description of an "unfinished or flood-resistant enclosure" in the Section 1.6.40 definition for Lowest Floor. Designs for meeting these requirements must comply with standards outlined in the adopted Oregon Structural Specialty Code and must meet or exceed the following minimum criteria: a. Appurtenant structures must only be used for parking, access, and/or storage and must not be used for human habitation; b. Must provide flood openings in accordance with section 4.5.110.04.b; c. Must not be used to store toxic material, oil, or gasoline, or any priority persistent pollutant identified by the Oregon Department of Environmental Quality unless confined in a tank installed in compliance with section 4.5.110.12; and, d. Must be constructed such that all electrical, mechanical, and ductwork is elevated or flood-proof to a minimum of 1-foot above the base flood elevation. 4.5.110.07 Below-grade Crawlspaces. Below-grade Crawlspaces are allowed, provided they conform to the following standards as found in FEMA Technical Bulletin 11-01, Crawlspace Construction for Buildings Located in Special Flood Hazard Areas: a. The building must be designed and adequately anchored to resist flotation, collapse, and lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. Hydrostatic loads and the effects of buoyancy can usually be addressed through the required openings stated in "b," below. Because of hydrodynamic loads, Crawlspace construction is not allowed in areas with flood velocities greater than five ft. per second unless the design is reviewed by a qualified design professional, such as a registered architect or licensed professional engineer. Other types of foundations are recommended for these areas; b. The Crawlspace is an enclosed area below the Design Flood Elevation (DFE) and, as such, must have openings that equalize hydrostatic pressures by allowing the automatic entry and exit of floodwaters. The bottom of each flood vent opening must be no more than one ft. above the lowest adjacent exterior grade; c. Portions of the building below the DFE must be constructed with materials resistant to flood damage. This includes not only the foundation walls of the Crawlspace used to elevate the building, but also any joists, insulation, or other materials that extend below the BFE. The recommended construction practice is to elevate the bottom of joists and all insulation above DFE; d. Any building utility systems within the Crawlspace must be elevated above DFE or designed so that flood waters cannot enter or accumulate within the system components during flood conditions. Ductwork, in particular, must either be placed above the DFE or sealed from flood waters; e. The interior grade of a Crawlspace below the DFE must not be more than two ft. below the lowest adjacent exterior grade; f. The height of the below-grade Crawlspace, measured from the interior grade of the Crawlspace to the top of the Crawlspace foundation wall must not exceed four ft. at any point. The height limitation is the maximum allowable unsupported wall height according to the engineering analyses and Building Code requirements for Special Flood Hazard Areas; g. The design must include an adequate drainage system that removes flood waters from the interior area of the crawlspace. The enclosed area should be drained within a reasonable time after a flood event. The type of drainage system will vary because of the site gradient and other drainage characteristics, such as soil types. Possible options include natural drainage through porous, well-drained soils and drainage systems such as perforated pipes, drainage tiles, or gravel or crushed stone drainage by gravity or mechanical means; and h. The velocity of flood waters at the site should not exceed five ft. per second for any Crawlspace. For velocities in excess of five ft. per second, other foundation types should be used (see "a," above). 4.5.110.08 Nonresidential Construction. a. New Construction, conversion to, and Substantial Improvement of any commercial, industrial, or other nonresidential structure must either have the Lowest Floor elevated at or above the Design Flood Elevation (DFE) and comply with residential construction in Section 4.5.110.04, or accomplish the alternative flood-proofing approach in "1" through "4" below. Lowest Floor includes basements, habitable attached garages, electrical, heating, ventilation, air conditioning equipment, ductwork, plumbing, and other service facilities. See definition for Lowest Floor in Section 1.6.40. The alternative approach includes: 1. Flood-proofing the Lowest Floor together with attendant utilities and sanitary facilities, so that the structure is watertight at or above the Design Flood Elevation (DFE); 2. Having the structural components of the Lowest Floor capable of resisting Hydrostatic and Hydrodynamic Loads and effects of buoyancy during the 100-yr flood event; and 3. Having the alternative design certified by a registered professional engineer or architect, stating that the design and methods of construction are in accordance with accepted standards of practice for meeting provisions of this subsection, based on their Development and/or review of the structural design, specifications, and plans; and 4. Providing volumetric exchange to account for the displaced flood storage volume per section 4.5.100.01. b. Designs for meeting the requirements in "a," above, must comply with standards outlined in the adopted Oregon Structural Specialty Code. c. The Floodplain Administrator or designee will notify applicants proposing to flood-proof nonresidential buildings that the flood insurance premiums will be based on rates for buildings and structures with a Lowest Floor that is one ft. below the flood-proofed level. 4.5.110.09 Non-conversion of Enclosed Areas Below the Lowest Floor. To ensure that the areas below the Base Flood Elevation (BFE) continue to be used solely for parking vehicles, limited storage, or access to the building and not be finished for use as human habitation without first becoming fully compliant with the provisions of this chapter and Chapter 2.11 - Floodplain Development Permit in effect at the time of conversion, the Floodplain Administrator or designee will: a. Determine which applicants for New Construction and/or Substantial Improvements have fully enclosed areas below the Lowest Floor that are five ft. or higher; b. Require the property owner to enter into a "NON-CONVERSION AGREEMENT FOR CONSTRUCTION WITHIN SPECIAL FLOOD HAZARD AREAS" or equivalent with the City of Corvallis. The Developer must record the agreement with Benton County as a deed restriction and provide a copy of the recorded document to the City. The non-conversion agreement will be reviewed and approved by the Floodplain Administrator or designee; and c. Have the authority to inspect any area of a structure below the Base Flood Elevation to ensure compliance upon prior notice of at least 72 hours. 4.5.110.10 Standards for Recreational Vehicles. a. For the purposes of this Section, Recreational Vehicle is defined as a vehicle which includes all the following characteristics: 1. Built on a single chassis; 2. 400 sq. ft. or less in size when measured at the largest horizontal projection; 3. Designed to be self-propelled or towable by a light duty truck; and 4. Not designed as a permanent dwelling; and 5. Designed for temporary uses; to include job trailers, construction trailers, mobile food units, or living quarters for recreational, camping, travel, or seasonal use. b. All Recreational Vehicles placed on sites within Federal Flood Zones A, AH, A1-A30, AE, AO, and A99 must either: 1. Be on the site for fewer than 180 consecutive days; 2. Be fully licensed and ready for highway use, on its wheels or jacking system, attached to the site only by quick disconnect-type utilities and security devices, and have no permanently attached structures or addition; or 3. Meet all standards of Section 4.5.110.03. 4.5.110.11 Critical Facilities. Construction of new Critical Facilities, as defined in Section 1.6.40, must be, to the maximum extent possible, located outside the limits of Special Flood Hazard Areas. Construction of new Critical Facilities is allowed within the Special Flood Hazard Area if no feasible alternative site is available. Critical Facilities constructed within Special Flood Hazard Areas must have the Lowest Floor elevated three feet above Base Flood Elevation (or Depth Number in AO Federal Flood Zones). Access to and from the Critical Facility must also, to the maximum extent possible, be protected to the height utilized above within the corresponding Special Flood Hazard Area(s). Any grade transition necessary to achieve the access protection requirement must be achieved outside of the corresponding Special Flood Hazard Area(s). Dry floodproofing and sealing measures must be used to ensure that toxic substances or priority organic pollutants, as defined by the Oregon Department of Environmental Quality, will not be displaced by or released into floodwaters. The Floodplain Administrator or designee will make the determination as to whether or not the Critical Facility's siting and access have achieved this provision's standards of "to the maximum extent possible." Some types of facilities may be critical to a community, but require location within or partially within Special Flood Hazard Areas because of the nature of the facilities. The Taylor Water Treatment plant along the Willamette River is an example of such a facility. It is pulling water from the Willamette River. Because of this fact, these types of facilities have purposefully been excluded from the definition of Critical Facility in Section 1.6.40. 4.5.110.12 Storage Tanks. a. Underground tanks in Special Flood Hazard Areas must be anchored to prevent flotation, collapse or lateral movement resulting from hydrostatic loads, including the effects of buoyancy assuming the tank is empty, during conditions of the design flood. b. Above-ground tanks in Special Flood Hazard Areas must be: 1. Attached to and elevated to or above the Base Flood Elevation (or Depth Number in AO Federal Flood Zones) and attached to a supporting structure that is designed to prevent flotation, collapse or lateral movement during conditions of the design flood; or be 2. Anchored or otherwise designed and constructed to prevent flotation, collapse or lateral movement resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy assuming the tank is empty, during conditions of the design flood. c. Tank inlets, fill openings, outlets and vents must be: 1. A minimum of 2 ft. above Base Flood Elevation (BFE) or fitted with covers designed to prevent the inflow of floodwater or outflow of the contents of the tank during conditions of the design flood; and 2. Anchored to prevent lateral movement resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy, during conditions of the design flood. 4.5.110.13 On-site Sewage Systems. a. Soil absorption systems must be located outside of Special Flood Hazard Areas. Where suitable soil absorption sites outside of Special Flood Hazard Areas are not available, the soil absorption site is permitted to be located within a Special Flood Hazard Area, provided the Floodplain Administrator or designee finds that it is located to minimize the effects of inundation under conditions of the Base Flood; and b. Mound systems are prohibited in Special Flood Hazard Areas. 4.5.110.14 Fences and Walls. Unless exempt per Section 2.11.40.b, the Developer must obtain a Floodplain Development Permit for fences and walls, and the fences and walls must comply with all of the standards in "a," and "b," below: a. Applicability - These provisions apply when fences and walls are not exempt per Section 2.11.40.b, and at least one of the following is true: 1. The velocity of the flood waters where the fence or wall is proposed is equal to or greater than 5 ft. per second. This velocity information must be obtained from one of the two following sources: a) The Flood Insurance Study for Benton County and Incorporated Areas, dated June 2, 2011; or b) For sites where no FEMA Flood Insurance Study is available, an independent Floodplain study approved by the Floodplain Administrator or designee and meeting all the requirements as outlined in Section 4.5.50.03.p; or 2. The velocity of flood waters information specified in "1," above, is not available from one of the two sources in Section 4.5.110.12.a.1. In these instances the velocity of flood waters will be assumed to be greater than 5 ft. per second. The purpose of the Floodplain Development Permit for fences and walls in Floodplain areas with unknown flood water velocities or velocities at least 5 ft. per second, even where the fences and walls meet the design parameters in Section 4.5.110.12.b, is to ensure proper documentation and consideration of Floodplain activities for the benefit of the Federal Emergency Management Agency (FEMA) and the Floodplain Administrator or designee. b. Fencing must comply with Table 4.5-1 Fencing and Wall Parameters for Fences and Walls that Require a Floodplain Development Permit. Table 4.5-1 Fencing and Wall Parameters for Fences and Walls that Require a Floodplain Development Permit (Those Fences and Walls Meeting Section 4.5.110.12.a) Fencing or Walls Allowed? Fence or Wall Type | Floodway Fringe | Floodway | Federal Flood Zones AH and AO A | Yes | Yes, provided Section 4.5.80.01 is met. | Yes B | Yes | Yes, provided Section 4.5.80.01 is met & there is limited cross channel fencing. | Yes C & D | Yes, if fence is completely open below the Base Flood Elevation | Yes, provided Section 4.5.80.01 is met & there is limited cross channel fencing. | AH Federal Flood Zone - Yes, if fence is completely open below the Base Flood Elevation. | AO Federal Flood Zone - Yes, if fence is completely open below the Flood Depth Number where Base Flood Elevation not known. E & F | Yes, if both of the following are met: 1. An opening or a flap is provided in the areas at or below the Base Flood Elevation at least once every three fence panels or 24 feet, whichever is less. Fences less than 24 feet in length shall have at least one flap or opening in the areas at or below Base Flood Elevation. The minimum dimensions of the opening or flap shall not be less than 12 in. × 12 or 8 in. × 18 in. In areas of the Floodway Fringe where Base Flood Elevation data is not available, the opening or flap shall be placed within one feet of the existing grade along the fence alignment; and | Yes, if both of the following are met: | 1. An opening or a flap is provided in the areas at or below the Base Flood Elevation in AH Federal Flood Zone and below Flood Depth Number in AO Federal Flood Zone, at least once every three fence panels or 24 feet, whichever is less. Fences less than 24 feet in length shall have at least one flap or opening in the areas at or below Base Flood Elevation. The minimum dimensions of the opening or flap shall not be less than 12 in. × 12 or 8 in. × 18 in. In areas of the Floodway Fringe where Base Flood Elevation data is not available, the opening or flap shall be placed within one feet of the existing grade along the fence alignment; and E & F con't | 2. Openings shall not include any screening of any size or type, except for flaps that are capable of self-release and open to the full dimensions when under pressure of no greater than 20 pounds per sq. feet | Yes, provided Section 4.5.80.01 is met & there is limited cross channel fencing. | 2. Openings shall not include any screening of any size or type, except for flaps that are capable of self-release and open to the full dimensions when under pressure of no greater than 20 pounds per sq. feet G | Yes for fence only, provided a licensed engineer provides documentation showing that the fence is designed to collapse under anticipated flood Base Flood conditions. The engineering analysis shall consider debris impact, size of posts, and velocity and depth of flood waters. | No | Yes for fence only, provided a licensed engineer provides documentation showing that the fence is designed to collapse under anticipated flood Base Flood conditions. The engineering analysis shall consider debris impact, size of posts, and velocity and depth of flood waters. A = Open barb or barbless wire. Open means no more than one horizontal strand per one feet of height. B = Open pipe or rail fencing (e.g. corrals). Open means rails occupy less than 10 percent of the fence area and posts are spaced no closer than 8 feet apart. C = Other wire, pipe, or rail fencing (e.g. field fence, chicken wire, etc.) which does not meet the requirements of "A," or "B," above. D = Chain link fencing E = Continuous Wood Fencing F = Masonry Walls (excluding retaining walls, as retaining walls are required by Section 4.5.110.12 to meet the same standards as other building, paving, and grading activities) G = Collapsible Fencing 4.5.110.15 Temporary Structures, Storage, and Bridges. A Floodplain Development Permit is required for construction or placement of temporary structures, temporary storage associated with nonresidential uses, and temporary bridges located in Special Flood Hazard Areas: a. Temporary structures, not including bridges, will be limited by the Floodplain Administrator or designee as to time of service, with the intent that the time of service is limited to the minimum time necessary to accomplish the temporary activity, per the provisions in "c," below. This time of service must not exceed 90 days. The Floodplain Administrator or designee is authorized to grant extensions for demonstrated cause; such cause will reaffirm the temporary nature of the structure. Temporary structures must be anchored to prevent flotation, collapse, or lateral movement. b. Temporary storage of fill will be limited by the Floodplain Administrator or designee as to time of service, with the intent that the time of service is limited to the minimum time necessary to accomplish the temporary activity, per the provisions in "c," below. This time of service must not exceed 90 days and the amount of temporary fill will be limited to no more than 50 cubic yards. The Floodplain Administrator or designee is authorized to grant extensions for demonstrated cause; such cause will reaffirm the temporary nature of the storage. Stored material must be anchored or contained to prevent flotation or release outside the assigned storage area. Hazardous materials priority persistent pollutants identified by the Oregon Department of Environmental Quality must not be stored in the Regulatory Floodway. c. Temporary encroachments, including bridges, in the Regulatory Floodway require approval of a Floodplain Development Permit subject to conditions "1" through "5", below. No CLOMR/LOMR is required. [2] 1. The Floodplain Development Permit will stipulate the days and dates the Development will be on site. The Floodplain Administrator or designee will determine the permissible period of encroachment based on the existing and expected hydrologic conditions of the 0.2-Floodway, as well as the type of and need for the encroachment. The Floodplain Administrator or designee is authorized to grant extensions for demonstrated cause; such cause will reaffirm the temporary nature of the Development and be based on the hydrologic conditions expected during the period of extension. The Floodplain Administrator or designee is authorized to place limits on the volume of materials placed within the Regulatory Floodway as a temporary encroachment and, when making such a determination, will consider the existing and expected hydrologic conditions during the period of encroachment, as well as the type of and need for the encroachment; 2. A flood warning plan for the project must be in place to allow equipment to be evacuated from the site and placed outside the Floodplain prior to inundation by flood waters; 3. Placement of equipment in the Floodway will be restricted to only that equipment which is absolutely necessary for the purposes of the project. All other accessory equipment and temporary structures (i.e., construction trailers) will be restricted from the Regulatory Floodway. Structures should be placed on site so that flood damages are minimized. In instances where the Floodplain Administrator or designee believes that evacuation isn't practical, the Floodplain Administrator or designee is authorized to require anchoring of construction trailers; 4. Temporary changes to the Floodplain under a one percent chance flood event (100-yr. flood) must be identified; and 5. The Floodplain Administrator or designee will notify the applicant in writing that the applicant may be liable for any flood damages resulting from the temporary structure.
(Ord. No. 2025-31, §§ 2, 8(Exh. A), 7-21-2025)
Ask a question about Corvallis law
Corpus searches the Corvallis sections it holds and shows the ones that match, with their citations. Free, no sign-in.