For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 660-61 — Roof types

Code of the City of Allentown, Pennsylvania (code date 2026-10-07) · Allentown Code § 660-61

Corpus is an independent public-information project, not the official City of Allentown website. Stable reference: corpuslaw.us/code/d4d26a63-83f4-49ac-a3a9-c424d34ecdef

§ 660-61: Roof types.

Each major component of any roof should meet the requirements of one of the roof types permitted per the building type regulations in Article 4. A. Regulations applicable to all roof types. (1) Roofs for bay or bow windows and dormers are not required to meet a roof type. (2) Terraces, green roofs, rooftop gardens, and other outdoor facilities are allowed on any roof and are not considered a roof type, except as follows: (a) Any permanently roofed, open-air area applies to the overall height as regulated by the building type regulations (Article 4), or may be treated as an interior building tower per § 660-62. (b) Any fully enclosed structure on a roof should meet the tower regulations per § 660-62. (c) Where any canopy or cover is visible from any public way or open space, the cover should comply with a roof type per this § 660-61. (3) Roofs, including all eaves or overhangs, should be fully located within the property lines of the lot, unless otherwise stated in § 660-131G, allowed encroachments into yards. See Article 4 for setback regulations. B. Other roof types. Other roof designs not defined in this section may be approved through the special exception process per § 660-115. C. Parapet roof type. A parapet is a low wall projecting above a building's roof along the perimeter of the building on all street facades and other front facades. See Figure 660(10), Examples of Parapet Roof Types. (1) Parapet height. Height is measured from the top of the upper story to the top of the parapet. (a) Minimum height is 1.5 feet with a maximum height of six feet. (b) A shadow line should be located within two feet of the top of the uppermost story. See § 660-150 for definition of shadow line. (c) A shadow line should be located at the top of the parapet. See § 660-150 for definition of shadow line. (2) Rooftop appurtenances. With the exception of solar panels and wind turbines, any rooftop appurtenances should be located towards the rear or interior of the parapet roof. Rooftop appurtenances should be located such that the parapet blocks their view from the sidewalk across the street or may be located within a tower per § 660-62. Figure 660(10), Examples of Parapet Roof Types [image] [image] D. Flat roof type. This roof type is a visibly flat roof with overhanging eaves or a cornice along front street facades. See Figure 660(11), Examples of Flat Roof Types. (1) Maximum slope. The maximum slope is 2:12; however, the roof should not appear to be visibly sloped from the front street or other front frontages. See Figure 660(8). (2) Street facades. For this roof type, either eaves on all street facades, or a cornice should be included on the front facade with a shadow line and cap on any other street facade. (3) Eaves. The following applies to street facade eaves: (a) Eave depth. Eaves should have a minimum depth of at least 14 inches. Eave depth is measured from the building facade to the outside edge of the eave. (b) Eave thickness. Eaves should be a minimum of six inches thick. Eave thickness is measured at the outside edge of the eave, from the bottom of the eave to the top of the eave. (4) Cornice. The following applies to front street cornice: (a) Cornice length. The cornice should extend the full length of the front street facade. (b) Cornice size. Cornices should be a minimum of 15 inches deep and 15 inches in height. (c) Cornice materials. The cornice should be constructed as a three-dimensional element, consisting of cast stone, masonry, marine-grade fiberglass, glass fiber reinforced concrete, composite stone, metal, wood, polyurethane, or natural stone. (5) Rooftop appurtenances. With the exception of solar panels and wind turbines, rooftop appurtenances should not be located on the flat portion of this roof type. Rooftop appurtenances should be located centrally on the roof such that their view is minimized from the street or may be located within a tower per § 660-62. Figure 660(11) Examples of Flat Roof Types [image] [image] Figure 660(8) Diagram of Roof Pitches [image] E. Pitched roof type. This roof type is a sloped or pitched roof, where the slope occurs on all street and other front facades. Slope is measured with the vertical rise divided by the horizontal span or run. See Figure 660(9), Examples of Pitched Roof Types. (1) Pitch measure. The roof should not be sloped less than a 4:12 (rise:run) or more than 14:12, unless otherwise expressly stated. See Figure 660(8). (2) Hipped or gabled roofs. Hipped, gabled, and combination of hips and gables with or without dormers are allowed. (a) When the ridge line runs parallel to any front street, one of the following should occur except as otherwise stated in the building type regulations: [1] A gabled end or perpendicular ridge line should occur at least every 100 feet of roof; or [2] One dormer should be provided for every 15 feet of ridge line on any street or front frontage with at least one dormer per frontage. [3] A bay with a separate roof on the front street facade or a tower per § 660-62, as allowed by building type. (b) Occupied building space within the roof is allowed and counts as a half or full story. See § 660-131M for definition of "half story" and any half story limitations per the building type regulations. See § 660-146 for definition of "occupied building space." (c) Maximum roof height. Pitched roofs with a ridge parallel to the front street and without occupied building space should have a maximum height on street facades equal to no more than 1.5 times the upper story floor-to-floor height utilized on the building. (3) Gambrel or mansard roof. Gambrel and mansard roofs should include the following: (a) Gambrel roofs with the ridge parallel to the street and mansard roofs should include one dormer for every 15 feet of ridge line on any street or other front with at least one dormer per frontage. (b) The steepest portion of the roof should be no greater than the tallest permitted height of one upper story. (c) Occupied building space should be included beneath the roof and counts as a half or full story. See § 660-131M for definition of "half story." See § 660-146 for definition of "occupied building space." (4) Rooftop appurtenances. With the exception of solar panels, antennae, and wind turbines, any rooftop appurtenances, where feasible, should be located on the rear sloping portion of the roof to limit visibility from the street. Figure 660(9) Examples of Pitched Roof Types [image] [image] [image] [image] [image]

Ask a question about Allentown law

Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.