§ 660-65: Facade elements.
A. Security grilles and bars. (1) Exterior bars and security grilles are prohibited on any street facade opening. (2) Security grilles must be fully retractable and located within the interior of the building. When retracted, the grilles may not be visible from the exterior of the building. B. Principal entryway. See Figure 660(17) for examples of defined principal entryways. Principal entrances to all buildings or units, except storefronts, must be visible from the street and clearly delineated through one or more of the following design features: (1) Roof or canopy. The entryway is covered by a roof or canopy differentiating it from the overall building roof type. (2) Porch. The entryway is through a porch. (3) Sidelights and transom. Sidelights or transom windows are included around the entryway. (4) Articulation. The entryway is included in a separate bay of the building that extends up at least two stories or in a recessed bay with a change in material. (5) Other methods. Other structural methods of substantially differentiating the entrance from the facade similar in scope to the examples of this section, not including paint, trim, or materials. Figure 660(17) Example of Defined Principal Entryways [image] | [image] C. Building articulation. See Figure 660(18) for examples of building facade variety. Buildings 120 feet in length or greater, as measured along any street frontage, must fulfill the following requirements: (1) Building variety. Each street and other front facade shall be varied in segments less than or equal to 60 feet. Each facade segment must vary by at least two of the following: (a) The type of dominant facade material or by color, scale, or orientation of that material; (b) The proportion of recesses and projections within the build-to zone; (c) The location of the entrance and window placement, unless storefronts are utilized; (d) Roof type, plane, or material, unless otherwise stated in the building requirements; (e) Building height. (2) Articulation of stories. Stories shall be articulated on street and other front facades per the following: (a) Fenestration. Fenestration or window placement on street facades shall be organized by stories per the building type facade transparency regulations. (b) Shadow lines. Horizontal shadow lines and lintels over openings may be used to delineate stories with minimum shadow lines required per building type. (c) Taller spaces. Mezzanines and other spaces exceeding the allowable floor to floor heights of the building type shall be articulated as multiple stories on the street facade per § 660-131N(5). Figure 660(18) Examples of Building Articulation [image] [image] D. Parking structure facades. Parking structure facades visible from any A or B street or other front shall meet the following standards. See Figure 660(16) for an illustration of a parking structure street facade. (1) Materials. Major and minor material requirements, per § 660-64, must be met on all street and other front facades. An additional permitted minor material is stained, finished concrete. (2) Ramps and slopes. Ramps and slopes may not be located on any A or B street facade or other front facade. (3) Screening of vehicles. Visibility of parked motor vehicles must be screened from the street by walls, screens, or vegetation with a minimum opacity of 50%. (4) Blank wall limitations. No rectangular area greater than 30% of any story's facade, as measured from floor to floor, and no horizontal segment of a story's facade greater than 15 feet in width may be solid wall without an opening. (5) Vertical divisions. Vertical divisions extending to the full height of the structure are required every 30 feet to deemphasize the horizontal decks. Divisions must be a minimum of two feet in width with a minimum projection of 1.5 inches. (6) Entry tower. A pedestrian entrance directly into the parking structure from the street is required to be separate from the vehicular entrance and directly accessed from the sidewalk. The pedestrian entrance must meet the principal entryway regulations in § 660-65B. Stairwells must be located inside a tower per § 660-62 with windows at a transparency rate of 65%. (7) Roof type. The top story of the parking structure must include a parapet or other roof type along all street or other front facades. Refer to roof types defined in § 660-61. (8) Vehicular entrances. Driveways must be no wider than 22 feet and the entrance and exit should be split by a median. Access must be located on a side street, unless the lot does not abut a side street. No more than two access points shall be located on any one street, totaling no more than 24 feet of drives crossing any street sidewalk. See § 660-70 for sight triangle regulations. (9) Openings. All openings shall be treated in a manner that creates the appearance of an active use area, and conceals all internal elements such as plumbing, pipes, fans, ducts, and lighting. Figure 660(16) Example of a Parking Structure [image]
Ask a question about Allentown law
Corpus searches the Allentown sections it holds and shows the ones that match, with their citations. Free, no sign-in.