§ 308 — PIPING SUPPORT

The Philadelphia Code (2026 Code: The Philadelphia Code and Home Rule Charter current through October 8, 2026) · Philadelphia Code Subcode P, § 308

Corpus is an independent public-information project, not the official City of Philadelphia website. Stable reference: corpuslaw.us/code/f413f3ff-713d-4572-b445-3d95a4cb3bf2

SECTION 308 PIPING SUPPORT

* * * P-308.3 Materials. Hangers, anchors and supports shall support the piping and the contents of the piping. Hangers and strapping material shall be of approved material that will not promote galvanic action. * * * TABLE P-308.5 HANGER SPACING PIPING MATERIAL | MAXIMUM HORIZONTAL SPACING (feet) | MAXIMUM VERTICAL SPACING (feet) PIPING MATERIAL | MAXIMUM HORIZONTAL SPACING (feet) | MAXIMUM VERTICAL SPACING (feet) Acrylonitrile butadiene styrene (ABS) pipe | 4 c | 10 b Aluminum tubing | 10 | 15 Brass pipe | 10 | 10 Cast-iron pipe | 5 a | 15 Chlorinated polyvinyl chloride (CPVC) pipe and tubing, 1 inch and smaller | 3 | 10 b Chlorinated polyvinyl chloride (CPVC) pipe and tubing, 1-1/4 inches and larger | 4 c | 10 b Copper or copper-alloy pipe | 12 | 10 Copper or copper-alloy tubing, 1-1/4 inch diameter and smaller | 6 | 10 Copper or copper-alloy tubing, 1-1/2 inch diameter and larger | 10 | 10 Cross-linked polyethylene (PEX) pipe 1 inch and smaller | 2.67 (32 inches) | 10 b Cross-linked polyethylene (PEX) pipe 1-1/4 inch and larger | 4 c | 10 b Cross-linked polyethylene/aluminum/cross-linked polyethylene (PEX-AL-PEX) pipe | 2.67 (32 inches) | 4 Lead pipe | Continuous | 4 Polyethylene/aluminum/polyethylene (PE-AL-PE) pipe | 2.67 (32 inches) | 4 Polyethylene of raised temperature (PE-RT) pipe 1 inch and smaller | 2.67 (32 inches) | 10 b Polyethylene of raised temperature (PE-RT) pipe 1-1/4 inch and larger | 4 c | 10 b Polypropylene (PP) pipe or tubing 1 inch and smaller | 2.67 (32 inches) | 10 b Polypropylene (PP) pipe or tubing, 1-1/4 inches and larger | 4 c | 10 b Polyvinyl chloride (PVC) pipe | 4 c | 10 b Stainless steel drainage systems | 10 | 10 b Steel pipe | 12 | 15 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. The maximum horizontal spacing of cast-iron pipe hangers shall be increased to 10 feet where 10-foot lengths of pipe are installed. b. For sizes 2 inches and smaller, a guide shall be installed midway between required vertical supports. Such guides shall prevent pipe movement in a direction perpendicular to the axis of the pipe. c. The maximum horizontal spacing of hangers shall be decreased to 3 feet where temperatures exceed 120 degrees Fahrenheit. * * *

Ask a question about Philadelphia law

Corpus searches the Philadelphia sections it holds and shows the ones that match, with their citations. Free, no sign-in.