(a) All owners of high-rise buildings shall meet the standards in this Section within four (4) years of the effective date of this Chapter, shall inspect and test all fire dampers and smoke dampers at least once every four (4) years, and shall inspect and test all smoke control systems at least once every six (6) months or twelve (12) months, as required under the applicable NFPA standard. (b) All owners of mid-rise buildings shall meet the standards in this Section within six (6) years of the effective date of this Chapter, shall inspect and test all fire dampers and smoke dampers at least once every six (6) years, and shall inspect and test all smoke control systems at least once every six (6) months or twelve (12) months, as required under the applicable NFPA standard. (c) All owners of restaurants shall meet the standards in this Section within six (6) years of the effective date of this Chapter, shall inspect and test all fire dampers and smoke dampers at least once every six (6) years, and shall inspect and test all systems at least once every six (6) months or twelve (12) months, as required under the applicable NFPA smoke control standard. (d) All owners of hospitals shall meet the standards in this Section within six (6) years of the effective date of this Chapter, shall inspect and test all fire dampers and smoke dampers at least once every six (6) years, and shall inspect and test all smoke control systems at least once every six (6) months or twelve (12) months, as required under the applicable NFPA standard. (e) All owners of residential properties located above a restaurant shall meet the standards in this Section with four (4) years of the effective date of this Chapter, shall inspect and test all fire dampers and smoke dampers at least once every four (4) years, and shall inspect and test all smoke control systems at least once every six (6) months or twelve (12) months, as required under the applicable NFPA standard. (f) Newly installed fire dampers, smoke dampers, and smoke control systems shall be inspected and tested within one (1) year of installation. In lieu of a satisfactory commissioning report of newly installed dampers, a full inspection of new dampers may be conducted. (g) All owners of buildings subject to this Chapter shall maintain full inspection and testing reports on the property and shall make such reports available for inspection upon request by an official of the Pittsburgh Bureau of Fire. (h) Fire dampers, smoke dampers, and smoke control systems shall be installed, inspected, tested, and maintained in accordance with this Chapter, manufacturers' guidelines and the applicable industry standards, on an ongoing basis.

[ Ord. No. 25-2016 , § 1, eff. 8-3-2016 ]

Ask a question about Pittsburgh law

Corpus searches the Pittsburgh sections it holds and shows the ones that match, with their citations. Free, no sign-in.