§ 802.04 — Requirements of Testing

Pittsburgh Code of Ordinances, Pennsylvania (Code 2026-11-04: eCode360 publication current through legislation 2026-11-04 (scraped 2026-11-19)) · Pittsburgh Code § 802.04

Corpus is an independent public-information project, not the official City of Pittsburgh website. Stable reference: corpuslaw.us/code/69442972-02a3-464b-afbb-08df22bf4cfb

§ 802.04: Requirements of Testing.

(a) Inspections and tests under this Section shall be performed by a contractor or engineer with the following qualifications: i. For inspection and testing of fire and Smoke Dampers, employ only persons who are certified to inspect and test fire and Smoke Dampers and have expertise in fire protection engineering, mechanical engineering and certification as air balancers. ii. For inspection and testing of Smoke Control Systems, employ only persons have expertise in fire protection engineering, mechanical engineering and certification as air balancers. (b) A building engineer or other person knowledgeable with the building system must accompany the inspector during the inspection and testing in order to provide building and systems access and information. (c) If an inspection or test reveals compliance with the requirements of this Section, the person performing the inspection or test shall execute a compliance certification which shall verify such compliance, and provide the name of the individual(s) conducting the inspection or test and that person's employer, the name of the building owner and address of the property, the location of all smoke dampers, fire dampers, and smoke control systems inspected or tested, and the date of the inspection or test. (d) In the event an inspection or test reveals deficiencies in smoke dampers, fire dampers, or smoke control systems, the person(s) who conducted the inspection or test shall prepare a deficiency report for the building owner identifying the nature of the deficiency and reasons for non-compliance. The building owner shall, within one hundred twenty (120) days of the date of the inspection or test, take necessary steps to ensure the defective equipment is replaced or repaired and that compliance with the requirements as set forth herein have been achieved. (e) In addition to identifying the location and nature of the deficiency, the report shall contain the name of the individuals conducting the inspection or test and that person's employer, the name of the building owner, address of the property, the location of all fire dampers, smoke dampers and smoke control systems inspected or tested, and the date of the inspection or test. (f) Tests and inspections of fire dampers, smoke dampers, and smoke control systems shall be conducted in accordance with the technical specifications and required time periods specified by NFPA Standards 80, 90, 90A, 92, and 105, as applicable. (g) In addition to the ordinary inspection and test requirements that buildings, structures, and parts thereof arc required to undergo as set forth herein, smoke control systems subject to this Ordinance shall undergo special inspections and tests sufficient to verify the proper commissioning of the smoke control design in its final installed condition. The design submission accompanying the construction documents shall clearly detail procedures and methods to be used and the items subject to such inspections and tests. Such commissioning shall be in accordance with generally accepted engineering practice and, where possible, based on published standards for the particular testing involved. The special inspections and tests required by this section shall be conducted under the same terms as in Section 1704 of the International Building Code.

[ Ord. No. 25-2016 , § 1, eff. 8-3-2016 ; Ord. No. 6-2024 , § 1, 4-10-2024 ]

Ask a question about Pittsburgh law

Corpus searches the Pittsburgh sections it holds and shows the ones that match, with their citations. Free, no sign-in.