Sec. 17-96. - Subsurface drainage requirements.

(a) Where pipe underdrains are required, they shall be installed two and one-half (2½) feet in back of the curb and shall be properly connected to a permanent type drainage outlet, such as a catch basin, junction box, or manhole. (b) Pipe underdrains (inert) shall be a minimum of twenty-four (24) inches below the bottom of the curb and shall be shown on the street profiles. Suitable outlets for the pipe underdrains at the required elevation shall be provided in the design of the drainage system. (c) Pipe underdrains, where required, shall be installed before the base course is placed. (d) In sections where mucking-out and back-filling have been done, pipe underdrains shall be installed on both sides of the street, as required. (e) Pipe underdrains shall be installed at low points in grade on both sides of the street for a minimum distance of one hundred (100) feet in each direction along the street. (f) Pipe underdrains shall be installed at street drainage outlets (other than low points in grade) on both sides of the street for a minimum distance of one hundred (100) feet in upgrade. (g) Pipe underdrains shall be installed on both sides of the street in cut sections when the cut is of such depth that the water table will temporarily be within twenty-four (24) inches of center line subgrade during extended periods of rainfall. (h) Pipe underdrains shall be placed in other locations as determined by the engineer for the developer or as required by the city engineer. (i) Pipe underdrains shall be properly laid on grade and in accordance with these specifications and the state highway department's standard specifications for highway construction and shall not be covered over until after they have been inspected and approved by the city engineer.

Ask a question about North Charleston law

Corpus searches the North Charleston sections it holds and shows the ones that match, with their citations. Free, no sign-in.