For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 21-178 — Ventilation

Code of Ordinances, City of Chattanooga, Tennessee (Supp. No. 40: codified through Ordinance No. 14374, enacted June 16, 2026) · Chattanooga City Code § 21-178

Corpus is an independent public-information project, not the official City of Chattanooga website. Stable reference: corpuslaw.us/code/bca3ae69-a8f5-4300-9fb5-c894a7c71098

Sec. 21-178. - Ventilation.

(a) Habitable Spaces. Every Habitable Space shall have at least one (1) openable window. The total openable area of the window in every room shall be equal to at least forty-five percent (45%) of the minimum glazed area required. Exception: Where rooms and spaces without openings to the outdoors are ventilated through an adjoining room, the unobstructed opening to the adjoining room shall be at least eight percent (8%) of the floor area of the interior room or space, but a minimum of twenty-five (25) square feet. The ventilation openings to the outdoors shall be based on the total floor area being ventilated. (b) Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces, except that a window shall not be required in such spaces equipped with a mechanical ventilation system. Air exhausted by a mechanical ventilation system from a bathroom or toilet room shall discharge to the outdoors and shall not be recirculated. (c) Cooking facilities. Unless approved through the certificate of occupancy, cooking shall not be permitted in any rooming unit or dormitory unit, and a cooking facility or appliance shall not be permitted to be present in the rooming unit or dormitory unit. Devices such as coffee pots and microwave ovens shall not be considered cooking appliances. The requirements set forth in this subsection shall not apply where specifically approved in writing by the Code Official. (d) Process ventilation. Where injurious, toxic, irritating or noxious fumes, gases, dusts or mists are generated, a local exhaust ventilation system shall be provided to remove the contaminating agent at the source. Air shall be exhausted to the exterior and not be recirculated to any space. (e) Clothes dryer exhaust. Clothes dryer exhaust systems shall be independent of all other systems and shall be exhausted outside the Structure in accordance with the manufacturer's instructions.

(Ord. No. 13442, § 1, 3-12-19)

Ask a question about Chattanooga law

Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.