Sec. 21-179. - Occupancy limitations.

(a) Privacy. Dwelling units, hotel units, housekeeping units, rooming units and dormitory units shall be arranged to provide privacy and be separate from other adjoining spaces. (b) Minimum room widths. A habitable room other than a kitchen shall be a minimum of seven (7) feet in any plan dimension. Kitchens shall have a minimum clear passageway of three (3) feet between counterfronts and appliances or counterfronts and walls. (c) Minimum ceiling heights. Habitable Spaces, hallways, corridors, laundry areas, bathrooms, toilet rooms and habitable basement areas shall have a minimum clear ceiling height of seven (7) feet. Exceptions: The following exceptions shall apply to the requirements for minimum ceiling heights set forth in this subsection: (1) In single-family dwellings and two-family dwellings, beams or girders spaced a minimum of four (4) feet on center and projecting a maximum of six (6) inches below the required ceiling height. (2) Basement rooms in one- and two-family dwellings occupied exclusively for laundry, study or recreation purposes, having a minimum ceiling height of six (6) feet eight (8) inches with a minimum clear height of six (6) feet four (4) inches under beams, girders, ducts and similar obstructions. (3) Rooms occupied exclusively for sleeping, study or similar purposes and having a sloped ceiling over all or part of the room, with a minimum clear ceiling height of seven (7) feet over a minimum of one-third (⅓) of the required minimum floor area. In calculating the floor area of such rooms, only those portions of the floor area with a minimum clear ceiling height of five (5) feet shall be included. (d) Bedroom and living room requirements. Every Bedroom and living room shall comply with the following requirements: (1) Room area. Every living room shall contain at least one hundred twenty (120) square feet and every bedroom shall contain a minimum of seventy (70) square feet and every bedroom occupied by more than one (1) person shall contain a minimum of fifty (50) square feet of floor area for each occupant thereof. (2) Access from bedrooms. Bedrooms shall not constitute the only means of access to other bedrooms or habitable spaces and shall not serve as the only means of egress from other habitable spaces. An exception to this requirement is for units that contain fewer than two (2) bedrooms. (3) Water closet accessibility. Every bedroom shall have access to at least one (1) water closet and one (1) lavatory without passing through another bedroom. Every bedroom in a dwelling unit shall have access to at least one (1) water closet and lavatory located in the same story as the bedroom or an adjacent story. (4) Prohibited occupancy. Kitchens and nonhabitable spaces shall not be used for sleeping purposes. (5) Other requirements. Bedrooms shall comply with the applicable provisions of this chapter, including, but not limited to, the light, ventilation, room area, ceiling height and room width requirements; the plumbing facilities and water-heating facilities requirements; the heating facilities and electrical receptacle requirements; and the smoke detector and emergency escape requirements. (e) Efficiency unit. Nothing in this section shall prohibit an efficiency living unit from meeting the following requirements: (1) A unit occupied by not more than one Occupant shall have a minimum clear floor area of one hundred twenty (120) square feet. A unit occupied by not more than two (2) Occupants shall have a minimum clear floor area of two hundred twenty (220) square feet. A unit occupied by three (3) occupants shall have a minimum clear floor area of three hundred twenty (320) square feet. These required areas shall be exclusive of the areas required by Items 2 and 3 of this subsection. (2) The unit shall be provided with a kitchen sink, cooking appliance and refrigeration facilities, each having a minimum clear working space of thirty (30) inches in front. Light and ventilation conforming to this chapter shall be provided. (3) The unit shall be provided with a separate Bathroom containing a water closet, lavatory and bathtub or shower. (4) The maximum number of Occupants shall be three (3). (f) Food preparation. All spaces to be occupied for food preparation purposes shall contain suitable space and equipment to store, prepare and serve foods in a sanitary manner. There shall be adequate facilities and services for the sanitary disposal of food wastes and other litter, including facilities for temporary storage.

(Ord. No. 13442, § 1, 3-12-19)

Ask a question about Chattanooga law

Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.