Sec. 4-12. - Exceedances of limitations on emissions.

(a) Purpose. The purpose of this section is to place reasonable limits on the amount of emissions an air pollutant source can emit due to a "malfunction" as defined in section 4-2, or during start-up or shutdown of said source. Without such limits air quality standards may not be met or public health and welfare may be endangered. [Formerly 4-12(a); New T.A.R. 1200-3-20-.01] (b) Reasonable measures required. Air pollutant sources must take all reasonable measures to keep emissions to a minimum during start-ups, shutdowns, operation, and malfunctions. These measures may include installation and use of alternate control systems, changes in operating methods or procedures, cessation of operation until the process equipment or air pollution control equipment is repaired, maintaining sufficient spare parts, use of overtime labor, use of outside consultants and contractors, and other appropriate means. Exceedances of limitations on emissions that are caused by poor maintenance, careless operation, or any other preventable upset condition or preventable equipment breakdown shall not be considered malfunctions, and shall be considered in violation of the emission standard exceeded and this section. [Formerly 4-12(b); New T.A.R. 1200-3-2-.02] (c) Reserved. (d) Reserved. (e) Notice Required When an Emission Limitation is Exceeded. (1) When any air pollutant emission source, air pollution control equipment or related emissions unit operates, or fails to operate, in such a manner as to cause the emission of air pollutants in excess of any applicable emission standard contained in this chapter or under any installation permit or certificate of operation issued thereunder, or of sufficient duration to cause damage to property or public health, the owner or operator of such source, air pollution control equipment, or related emissions unit shall promptly notify the director of such excess emissions, specifying that it is a malfunction if that is the case, and provide a statement giving all pertinent facts sufficient for the director to determine whether the exceedance is a malfunction, including the estimated duration of the excess emissions. (2) Prompt notification shall mean an initial telephone report to the bureau within twenty-four (24) hours after the onset of the excess emissions, followed up by a written report submitted to the bureau within seven (7) days after the onset of the excess emissions. The written report shall include the information described in section 4-12(f)(1)a.1 through a.8. The director shall be notified when the condition causing the excess emissions has been corrected and the source or equipment is again in operation. Any excess emissions that create an imminent hazard requiring immediate action to protect health or safety must be reported by telephone immediately to the bureau and to the appropriate local emergency response agency and to the Tennessee Emergency Management Agency. [Formerly 4-12(c); T.A.R. 1200-3-20-.06] (f) Logs and reports. (1) a. A log of any operation or failure to operate, start-up, or shutdown resulting in air pollutant emissions in excess of any applicable standard in this chapter, or of any installation permit or certificate of operation issued thereunder, by any source must be kept at the source. This log must record at least the following: 1. Stack, air pollution control equipment, or emission point involved; 2. Time excess emissions, start-up, or shutdown began or when excess emissions were first discovered by the source; 3. Type of exceedance qualifying as a malfunction, or reason for shutdown; 4. Time start-up or shutdown was complete or time the air pollutant source returned to normal operation after an emissions exceedance; 5. Documentation that the source was or was not, at the time of the onset of the exceedance, being properly operated; 6. Documentation of any preventative maintenance of the air pollution control equipment or process equipment or processes that had been completed prior to the emissions exceedance, start-up, or shutdown; 7. The steps taken by the source during the period of the emissions exceedance, start-up, or shutdown to minimize levels of emissions that exceeded the emission standards, or other requirements in the installation permit or certificate of operation; and 8. The magnitude and identity of the excess emissions, expressed in pounds per hour and the units of the applicable emission limitation, and the operating data and calculations used in determining the magnitude of the excess emissions. 9. The employee of the owner or operator making entry on the log must sign, date and indicate the time of each log entry. b. The information under items (f)(1)a.1. and 2. of this subsection must be entered into the log by the end of the shift during which the emissions exceedance, start-up or shutdown began. c. All information shall be entered in the log no later than twenty-four (24) hours after the start-up or shutdown is complete, or the emissions exceedance has ceased or has been corrected. d. Any later discovered corrections may be added in the log as footnotes with the reason given for the change. There shall be no erasures, obliterations, modifications, or revisions of the log entry except by single line-through and identification of corrections. (2) The owner or operator of a source located in a nonattainment area or having a significant impact on the air quality in a nonattainment area (for the nonattainment pollutant) in a calendar quarter must submit a report to the director within thirty (30) days after the end of such calendar quarter listing the times and dates at which any emissions exceedance, start-up, or shutdown resulted in emissions greater than any applicable emission limits under this chapter, or under any installation permit or certificate of operation issued thereunder, and the estimated amount of emissions discharged during such times. This report should also include total emissions during the quarter and be reported in a format specified by the director. If these emissions are required to be reported and are reported as required under section 4-41, Rule 15, then the report required by this paragraph is waived. [Formerly 4-12(d) and (g)(2); T.A.R. 1200-3-20-.04 and 1200-3-20-.06] (g) Copies of log required. The director may require the owner or operator of any air pollutant source to submit a copy of the emissions exceedance, start up and shutdown log required under subsection (e) of this section to the director ten (10) days after the request is received. The director can require submission of copies of the entire log. [Formerly 4-12(e); T.A.R. 1200-3-20-.05] (h) Special reports required. The director may require any air pollutant source to submit a report within thirty (30) days after the end of each calendar quarter in a format he specifies containing as a minimum the following information: (1) The dates on which emissions exceedances, start-ups, and shutdowns resulted in emissions greater than those allowed by the emission standards in this chapter or any installation permit or certificate of operation issued thereunder; (2) The estimated amount of air pollutants emitted in excess of the emission standards in units of pounds of air pollutant per hour and pounds of air pollutant per day; (3) Other emission characteristics such as stack exit temperature, stack height and diameter, stack exit velocities, and other similar information; (4) Information needed to evaluate the possibility of instituting measures to eliminate or reduce the number of emission exceedances or the amount of emissions from emission exceedances, start-ups, and shutdowns; (5) Information to determine if the excess emissions truly resulted from a malfunction; and (6) Information to evaluate the impact of the emissions on the surrounding area.

(Code 1986, § 4-12; Ord. No. 9171, § 5, 5-30-89; Ord. No. 10277, § 9, 8-15-95; Ord. No. 14165, §§ 3, 4, 10-29-24)

Ask a question about Chattanooga law

Corpus searches the Chattanooga sections it holds and shows the ones that match, with their citations. Free, no sign-in.