For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 12-54 — Standards for areas of shallow flooding (AO and AH zones)

Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Code of Ordinances § 12-54

Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/af1485a2-ccb7-489b-b5b0-3bda17c9e65a

Sec. 12-54. - Standards for areas of shallow flooding (AO and AH zones).

(a) Located within the special flood hazard areas established in article I, section 12-5 may be areas designated as shallow flooding areas (AO Zones.) These areas have special flood hazards associated with base flood depths of one (1) to three (3) feet where a clearly defined channel does not exist and where the path of flooding is unpredictable and indeterminate. Therefore, the following provisions apply: (1) All new construction and substantial improvements of non-residential and residential buildings shall have the lowest floor, including basement, elevated to at least one (1) foot above as many feet as the depth number specified on the flood insurance rate map, in feet, above the highest adjacent grade. If no flood depth number is specified on the FIRM, the lowest floor, including basement, shall be elevated at least three (3) feet above the highest adjacent grade. Openings sufficient to facilitate automatic equalization of hydrostatic flood forces on exterior walls shall be provided in accordance with standards of article III, section 12-52, and "enclosures." (2) All new construction and substantial improvements of non-residential buildings may be flood- proofed in lieu of elevation. The structure together with attendant utility and sanitary facilities must be flood proofed and designed watertight to be completely flood-proofed to at least one (1) foot above the flood depth number specified on the FIRM, with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. If no depth number is specified, on the FIRM, the structure shall be flood proofed to at least three (3) feet above the highest adjacent grade. A Tennessee-registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions of this ordinance and shall provide such certification to the engineering department as set forth above and as required in article II, section 12-32. (3) Adequate drainage paths shall be provided around slopes to guide floodwaters around and away from proposed structures. (b) Located within the special flood hazard areas established in article I, section 12-5, are areas designated as shallow flooding areas (AH zones). These areas are subject to inundation by one-percent-annual-chance shallow flooding (usually areas of ponding) where average depths are one (1) to three (3) feet. Base flood elevations are derived from detailed hydraulic analyses are shown in this zone. In addition to sections 12-51 and 12-52, all new construction and substantial improvements shall meet the following requirement: adequate drainage paths shall be provided around structures on slopes, to guide floodwaters around and away from proposed structures.

(Ord. No. O-112-2013, § 1, 6-25-13; Ord. No. O-97-2019, § 3, 7-2-19; Ord. No. O-170-2020, § 8, 11-17-20)

Ask a question about Knoxville law

Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.