For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.4 — DESIGN STANDARDS

Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Zoning Code, art. 5, § 5.4

Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/b1b8f41e-e19b-4ff3-916c-33fa5a75696f

5.4 - DESIGN STANDARDS

The following design standards applies to new construction and to any additions to a structure existing as of the effective date of this Code that exceed 30% or more of the existing structure's square footage. (Design standards for development in the DK Districts are found in Sections 5.5 below.) A. Commercial Districts Design Standards 1. Table 5-2: Commercial Districts Design Standards establishes the design standards for the C-N, C-G, C-H-2, C-R-2, and O Districts. In the table, a "•" indicates that the standard is applicable in the district indicated. The absence of a "•" indicates that the standard does not apply to the district. 2. For residential structures, the principal use standards in Section 9.3. shall apply when in conflict with the Commercial Districts Design Standards in Table 5-2. The design standards in Table 5-2 do not apply to single-family and two-family dwellings. Mixed-use structures that include residential uses must meet the standards in Table 5-2. Table 5-2: Commercial Districts Design Standards | | | | | | C-N | C-G | C-H-2 | C-R-2 | O Façade Design | | | | | Building façades that abut a public right-of-way, excluding alleys, must not contain blank wall areas that exceed 30 linear feet, measured per story parallel to the street. | • | • | • | • | Building façades in excess of 100 linear feet that abut a public right-of-way, excluding alleys, must include a repeating pattern with no less than two of the following elements: texture change, material module change, or a wall articulation change of no less than 2 feet in depth or projection, such as a reveal, pilaster, or projecting rib. All elements must repeat at intervals of no more than 50 linear feet. | • | • | • | • | All buildings must have a public entrance from the sidewalk along the primary building frontage. Public entrances must be visually distinctive from the remaining portions of the façade along which they are located. | • | • | • | • | Building materials and visual elements used on the primary building frontage must continue on all building façades that are visible from a public right-of-way. | • | • | • | • | • Fenestration Design | | | | | The ground floor of the front façade that abuts a public-right-of-way, excluding alleys, must maintain a minimum transparency of 30%, measured between two and ten feet in height . | • | • | • | • | • Upper floors of the front façade must maintain a minimum transparency of 15% of the wall area of the story | • | • | | | Commercial Site Design | | | | | Sites must be designed to ensure safe pedestrian access from the public right-of-way, and safe pedestrian circulation within the development. | • | • | • | • | • A cohesive character must be established through the use of coordinated hardscape (paving materials, lighting, street furniture, etc.) and landscape treatments within the development. | | • | • | • | Outlot buildings must meet the minimum transparency requirements of the district along façades facing the street. | | | | • | Any outlot buildings must include prominent entrances oriented toward both the street and the interior parking lot. | | | | • | Outlot buildings that are part of a multi-tenant retail center must provide definition along the street frontage of the center by placement of the front building line within 0' to 30' of the front lot line. Outlot buildings may be placed within a required setback to comply with this standard. | | | | • | B. Building Material Restrictions In the C-N, C-G, C-H-2, C-R-2, and O Districts, the following building materials are prohibited on any façade facing a public right-of-way, excluding alleys, or any façade that abuts a residential district. Such materials may still be used as decorative or detail elements for up to 25% of the façade, or as part of the exterior construction that is not used as a surface finish material. 1. Concrete Plain concrete masonry units (CMU); 2. Aluminum, steel or other metal sidings; this restriction does not include metal architectural wall panels; 3. Exposed aggregate concrete wall panels; 4. T-111 composite plywood siding; 5. Plastic; 6. Vinyl. C-N DISTRICT DESIGN STANDARDS ![Figure: AppB-5-4-1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/ca9983915fd42916bf62579a9f43428f26f781565af6981e3aa2ab60d6faa7ed-AppB-5-4-1.png) C-G DISTRICT DESIGN STANDARDS ![Figure: AppB-5-4-2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/b41b03e43c58fd56fb6f7cbe7390900b672d7e075c71837e81d41f07f58ae46e-AppB-5-4-2.png) C-H-2 DISTRICT DESIGN STANDARDS ![Figure: AppB-5-4-4.png](https://figures.74-208-44-221.nip.io/knoxville/497059/23697ce5f86694fc7d251ffbe8b4ae15629cf1be99b98aa83e05d70abcd3f28a-AppB-5-4-4.png) C-R-2 DISTRICT DESIGN STANDARDS ![Figure: AppB-5-4-5.png](https://figures.74-208-44-221.nip.io/knoxville/497059/e25b6919736f802adbd0bd8f1eb2d1fc5a05c968d97f66ec23c03b5c3d817937-AppB-5-4-5.png)

(Ord. No. O-113-2024, § 1, 9-17-24)

Ask a question about Knoxville law

Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.