For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.5 — DK DISTRICT STANDARDS

Code of Ordinances, City of Knoxville, Tennessee (Supplement 81; codified through Ordinance O-51-2026, June 23, 2026; online September 9, 2026; later unincorporated ordinances excluded) · Knoxville Zoning Code, art. 5, § 5.5

Corpus is an independent public-information project, not the official City of Knoxville website. Stable reference: corpuslaw.us/code/8d26aa3c-13ec-473d-afe7-40779c8992d3

5.5 - DK DISTRICT STANDARDS

A. Subdistricts Established The DK District is intended to accommodate the unique development environment within downtown. To facilitate development that reinforces and enhances the existing varied character areas of downtown Knoxville, the DK District is divided into five sub-districts that include tailored dimensional and design standards related to their specific contexts. These sub-districts are: 1. DK-B Downtown Knoxville Boulevards Subdistrict The DK-B Downtown Knoxville Boulevards Subdistrict is intended to accommodate those areas of Downtown Knoxville that have developed in a manner characterized by wide, planted boulevards, and a green, open landscape consisting of lawns, plazas and structures at variable setbacks. 2. DK-G Downtown Knoxville Grid Subdistrict The DK-G Downtown Knoxville Grid Subdistrict is intended to accommodate those areas of Downtown predominantly characterized by the traditional 300-foot by 300-foot grid pattern established in the Plan of the City of Knoxville. It is recognized that this central area is likely to be the most intensely developed portion of the downtown, and the standards are therefore designed to ensure that future development maintains the pedestrian orientation and mixed-use environment characteristic of the traditional grid. 3. DK-H Downtown Knoxville Historic Core Subdistrict The DK-H Downtown Knoxville Historic Core Subdistrict is intended to accommodate those areas of Downtown Knoxville characterized by a heterogeneous mix of uses organized within a highly-walkable environment with a continuous, consistent street-wall, and a preponderance of historic and cultural resources. 4. DK-W Downtown Knoxville Warehouse Subdistrict The DK-W Downtown Knoxville Warehouse Subdistrict is intended to accommodate the area located primarily along Jackson Avenue and the rail yard on the north end of Downtown Knoxville, and characterized by a mix of retail and warehouse/industrial uses in historically significant structures. Subdistrict standards are designed to allow the continued mix of uses in this area, and to reinforce the existing built character of the Warehouse Subdistrict. 5. DK-E Downtown Edge Subdistrict The DK-E Downtown Edge Subdistrict is intended to address areas of transition between the higher intensity environment of the Downtown and adjacent smaller-scale mixed-use areas. The DK-E Subdistrict facilitates mixed-use development with standards that focus on compatibility with adjacent development. B. DK Subdistricts Dimensional Standards 1. Table 5-3: DK Subdistricts Dimensional Standards establishes the dimensional standards for the Downtown Subdistricts. These regulations apply to all uses within the district unless a different standard is listed for a specific use. 2. A minimum ground floor height of 12 feet measured from floor to floor is required in the DK-G and DK-H Subdistricts. 3. Buildings over 85 feet in height are required to incorporate a stepback a minimum of ten feet from the street-facing façade plane. Such stepback must occur above the third story, and below the seventh story. Table 5-3: DK Subdistricts Dimensional Standards | | | | | | DK-B | DK-G | DK-H | DK-W | DK-E Bulk | | | | | Maximum Building Height | Unlimited | Unlimited | 125 | Unlimited | 85' Minimum Building Height | None | 24' | 24' | None | None Setbacks | | | | | Minimum Setback from Street Lot Line | Build-to-Zone: 0'—25' | Build-to-Zone: 0'—5' | Build-to Zone: 0'—5' | Build-to-Zone: 0'—15' | Build-to-Zone: 0'—20' Minimum Build-To Percentage | N/A | 80% | 100% | 80% | 70% Interior Side Setback | None | None | None | None | None Rear Setback | None, unless abutting a residential district, then 15' | None | None | None | None, unless abutting a residential district, then 25' C. Design Standards 1. Table 5-4: DK Subdistricts Design Standards indicates the applicability of design standards for the DK Subdistricts. In the table, a "•" indicates that the standard is applicable in the subdistrict indicated. The absence of a "•" indicates that the standard does not apply to the subdistrict. 2. New construction and certain expansion and alteration actions within the DK District, as described in the Downtown Design Review in Section 16.5, are subject to review and approval by the Design Review Board per Section 16.5 (this excludes the DK-E Sub-District per item 3 below). The Downtown Knoxville Design Guidelines contain standards that the Design Review Board will use to review such development per Section 16.5, in addition to Table 5-4. 3. The DK-E Sub-District is not subject to review by the Design Review Board, but still requires site plan review by Knoxville-Knox County Planning Commission staff. Only the design standards of Table 5-4 apply to the DK-E Sub-District. These design standards apply to new construction and to any additions to a structure existing as of the effective date of this Code that exceed 30% or more of the existing structure's square footage. Table 5-4: DK Subdistricts Design Standards | | | | | | DK-B | DK-G | DK-H | DK-W | DK-E Façade Design | | | | | Building façades that abut a public right-of-way, excluding alleys, must incorporate building entries no less than once every 50 feet. | | • | • | • | • Building façades that abut a public right-of-way, excluding alleys, must not contain blank wall areas that exceed 35 linear feet, measured parallel to the street. | • | | | • | • Building façades that abut a public right-of-way, excluding alleys, must not contain blank wall areas that exceed 20 linear feet, measured parallel to the street. | | • | • | | Fenestration Design | | | | | The ground floor of the front façade must maintain a minimum transparency of 30%, measured between two and ten feet in height. | • | • | • | • | • Upper floors of the front façade must maintain a minimum transparency of 15% of the wall area of the story. | • | | | • | • Upper floors of the front façade must maintain a minimum transparency of 25% of the wall area of the story | | • | • | | D. DK District Building Material Restrictions The following building materials are prohibited on any façade facing a public right-of-way, excluding alleys, or any façade that abuts a residential district. Such materials may still be used as decorative or detail elements for up to 25% of the façade, or as part of the exterior construction that is not used as a surface finish material. The Design Review Board, as part of Design Review, may approve the use of such restricted materials on a case by case basis. The Design Review Board must find that use of these materials as primary building material is a creative approach to building form that allows for an architecturally and/or environmentally innovative design. This does not apply to the DK-E Sub-District which must comply with these building material restrictions. 1. Plain concrete masonry units (CMU); 2. Aluminum, steel or other metal sidings; this restriction does not include metal architectural wall panels; 3. Exposed aggregate concrete wall panels; 4. T-111 composite plywood siding; 5. Plastic; 6. Vinyl; 7. Exterior insulation and finish system (EIFS). DK-B SUBDISTRICT DESIGN STANDARDS ![Figure: AppB-5-5-1.png](https://figures.74-208-44-221.nip.io/knoxville/497059/107ed8b7c731b6d9dc4c509e0432b0d822b2ba4a4eeb724208da7fa1fe9b77b4-AppB-5-5-1.png) DK-G SUBDISTRICT DESIGN STANDARDS ![Figure: AppB-5-5-2.png](https://figures.74-208-44-221.nip.io/knoxville/497059/b9f6f7c6ca016cc817112680144e13bf33d849f483f84ec605e581ba6a314ebd-AppB-5-5-2.png) DK-H SUBDISTRICT DESIGN STANDARDS ![Figure: AppB-5-5-3.png](https://figures.74-208-44-221.nip.io/knoxville/497059/a694af0b40c6ef1c8883fe7eaacd872e7972f0709b00cb477234d092f6c58b5f-AppB-5-5-3.png) DK-W SUBDISTRICT DESIGN STANDARDS ![Figure: AppB-5-5-4.png](https://figures.74-208-44-221.nip.io/knoxville/497059/e6f908e6237740aa950dd12e6e00ff7714f8e47356a41ec1a7a496954e527f4a-AppB-5-5-4.png)

Ask a question about Knoxville law

Corpus searches the Knoxville sections it holds and shows the ones that match, with their citations. Free, no sign-in.