§ 33-18 — Definitions

Code of Ordinances, City of Murfreesboro, Tennessee (Supp. No. 18: codified through Ordinance No. 26-O-38, enacted September 17, 2026) · Murfreesboro City Code § 33-18

Corpus is an independent public-information project, not the official City of Murfreesboro website. Stable reference: corpuslaw.us/code/d759227f-0f3a-4fcd-ac6f-95afd83b9fc6

Section 33-18 - Definitions.

The following definitions and terms shall apply in the interpretation and enforcement of Code §§ 33-18 through 33-22: "Air gap" shall mean a physical separation between the free flowing discharge end of a potable water supply line and an open or non-pressurized receiving vessel. "Approved air gap" shall mean a separation of at least twice the inside diameter of the supply line when measured vertically above the overflow rim of the vessel, but in no case less than one inch. "Approved" shall mean any condition, device, method or procedure is accepted by the Tennessee Department of Environment and Conservation, Division of Water Supply, and by the Department. "Atmospheric vacuum breaker" shall mean a device which prevents backsiphonage by creating an atmospheric vent when there is either a negative pressure or sub-atmospheric pressure in the water system. "Auxiliary intake" shall mean any piping connection or other device whereby water may be secured from any sources other than from the public water supply. "Auxiliary water supply" shall mean any water supply on or available to the premises other than water supplied by the public water system. "Backflow" shall mean the reversal of the intended direction of flow of water or mixtures of water and other liquids, gases, or other substances into the distribution pipes of a potable water system from any source. "Backflow connection" shall mean any arrangement whereby a backflow can occur. "Backpressure" shall mean a pressure in the downstream piping that is higher than the supply piping. "Backflow prevention assembly" shall mean an approved assembly designed to prevent backflow into the potable water system. "Backsiphonage" shall mean negative or sub-atmospheric pressure in the supply piping. "Bypass" shall mean any system of piping or other arrangement whereby water from the public water system can be diverted around a backflow prevention device. "Containment" shall mean a method of backflow prevention which requires the installation of an air gap or a backflow prevention assembly immediately following the water meter or as close to that location as deemed practical by the Department. "Contamination" shall mean the introduction or admission of any foreign substances that causes illness or death. "Contaminant" shall mean any substance introduced into the public water system that will cause illness or death. "Cross-connection" shall mean any physical arrangement whereby a public water supply is connected, directly or indirectly, with any other water supply system, sewer, drain, conduit, pool, storage reservoir, plumbing fixture, or other device which contains, or may contain, contaminated water, sewage, or other waste or liquid of unknown or unsafe quality which may be capable of contaminating the public water supply as a result of backflow caused by the manipulation of valves, because of ineffective check valves or backpressure valves or because of any other arrangement. "Cross-connection Control Program Coordinator/Officer" shall mean the person who is vested with the authority and responsibility for the implementation of the Cross-Connection Control Program and this ordinance. "Customer" shall mean any natural or artificial person, business, industry, or governmental entity that obtains water, by purchase or without charge, from the Department. "Department" shall mean the Murfreesboro Water Resources Department. "Direct cross-connection" shall mean an actual or potential cross-connection subject to backsiphonage and backpressure. "Director" shall mean the Director of the Water Resources Department of the City of Murfreesboro or authorized deputy, agent or representative. "Double check detector assembly" shall mean a specially designed assembly composed of line size approved double check valve assembly, with a bypass containing a water meter and approved double check valve assembly specifically designed for such application. The meter shall register accurately for very low rates of flow up to three gallons per minute and shall show a registration for all rates of flow. This assembly shall only be used to protect against non-health hazards and is designed primarily for use on fire sprinkler systems. "Double check valve assembly" shall mean an assembly of two internally loaded check valves, either spring loaded or internally weighted, installed as a unit between tightly closing resilient seated shut-off valves and fitted with properly located resilient seated test cocks. This type of device shall only by used to protect against non-health hazard pollutants. "Failed" shall mean the status of a backflow prevention assembly determined by a performance evaluation based on the failure to meet all minimums set forth by the approved testing procedure. "Fire System Classifications Protection" shall mean the classes of fire protection systems, as designated by the American Water Works Association "M14" for cross-connection control purposes based on water supply source and the arrangement of supplies, are as follows: (A) Class 1 shall mean those with direct connections from the public water mains only; no pumps, tanks, or reservoirs; no physical connection from other water supplies; no antifreeze or other additives of any kind; all sprinkler drains discharging to the atmosphere, dry wells or other safe outlets. (B) Class 2 shall mean the same as Class 1 except that booster pumps may be installed in the connections from the street mains. (C) Class 3 shall mean those with direct connection to public water supply mains in addition to any one or more of the following: elevated storage tanks, fire pumps taking suction from above ground covered reservoirs or tanks; and pressure tanks. (D) Class 4 shall mean those with direct connection from the public water mains, similar to Class 1 and Class 2, with and auxiliary water supply dedicated to fire protection and available to the premises, such as an auxiliary supply located within 1,700 feet of the pumper connection. (E) Class 5 shall mean those with direct connection from the public water mains and interconnected with auxiliary supplies, such as pumps taking suction from reservoirs exposed to contamination, or from rivers, ponds, wells, or industrial water systems; or where antifreeze or other additives are used. (F) Class 6 shall mean those with combined industrial and fire protection systems supplied from the public water mains only, with or without gravity storage or pump suction tanks. "Hazard, Degree of" shall mean a term derived from evaluation of the potential risk to public health and the adverse effect of the hazard upon the public water system. "Hazard, Health" shall mean a cross-connection or potential cross-connection involving any substance that could, if introduced in the public water supply, caused death, illness, and spread disease. "Hazard, High" shall mean a site where there is less risk of contamination, or less likelihood of cross-connections contaminating the system than a high risk hazard but where any substance that could, if introduced in the public water supply, cause death, illness, or spread disease. "Hazard, High Risk" shall mean a site capable of posing a significant risk of contamination or that may create conditions which pose an extreme hazard of immediate concern of death, illness, or spread disease. "Hazard, Low" shall mean a site where any substance introduced would not be a health hazard but would constitute a nuisance or be aesthetically objectionable if introduced into the public water supply. "Hazard, Plumbing" shall mean a cross-connection in a Customer's potable water system plumbing that is not properly protected by an approved air gap or backflow prevention assembly. "Hazard, Non-Health" shall mean a cross-connection or potential cross-connection involving any substance that would not be a health hazard but would constitute a nuisance or be aesthetically objectionable if introduced into the public water supply; also known as a Low Hazard. "Indirect Cross-connection" shall mean actual or potential cross-connection subject to backsiphonage only. "Industrial fluid" shall mean any fluid or solution that may be chemically, biologically, or otherwise contaminated or polluted in a form or concentration that could constitute a health, system, pollution, or plumbing hazard if introduced into the public water supply. This shall include, but is not limited to: polluted or contaminated water; all types of process water or used water originating from the public water system and that may have deteriorated in sanitary quality; chemicals; plating acids and alkalis; circulating cooling water connected to an open cooling tower; cooling towers that are chemically or biologically treated or stabilized with toxic substances; contaminated natural water systems; oil, gases, glycerin, paraffin, caustic, and acid solutions and other liquid or gases used in industrial processes or for fire purposes. "Inspection" shall mean an on-site evaluation of an establishment to determine if backflow prevention assemblies are needed by the Customer to protect the public water system from actual or potential cross-connections. "Interconnection" shall mean any system of piping or other arrangement whereby the public water system is connected directly with a sewer, drain, conduit, pool, storage reservoir, or other device, which does or may contain sewage or other waste, or liquid which would be capable of imparting contamination to the public water system. "Main" shall mean the principal artery of any system of continuous piping to which branches may be connected. "Non-potable water" shall mean water not safe for drinking, personal or culinary utilization. Repurified water is considered non-potable water. "Passed" shall mean the status of a backflow prevention assembly determined by a performance evaluation in which the assembly meets all minimums set forth by the approved testing procedure. "Performance evaluation" shall mean an evaluation of an approved Double check valve assembly or Reduced pressure principle assembly (including approved detector assemblies) using the latest approved testing procedures in determining the status of the assembly. "Person" shall mean any individual, corporation, company, proprietorship, association, partnership, State, municipality, utility district, water cooperative, or Federal agency. "Point of entry" shall mean the point of connection to the potable water system. "Pollutant" shall mean a substance in the public water system that would constitute a non-health hazard and that would be aesthetically objectionable if introduced into the public water supply. "Pollution" shall mean the presence of a pollutant or substance in the public water system that degrades its quality so as to constitute a non-health hazard. "Potable water" shall mean water which meets the criteria of the Tennessee Department of Environment and Conservation and the Environmental Protection Agency for human consumption. "Pressure vacuum breaker" shall mean an assembly consisting of a device containing one or two independently operating spring loaded check valves and an independently operating spring loaded air inlet valve located on the discharge side of the check valve(s), with tightly closing shut-off valves on each side of the check valves and properly located test cocks for the testing of the check valves and relief valve. The assembly is approved for internal use only and is not approved for premise isolation by the State of Tennessee. "Public water supply or public water system" shall mean the Murfreesboro Water Resources Department, which furnishes water to the City for general use and which is recognized as the public water supply by the Tennessee Department of Environment and Conservation. "Reduced pressure principle assembly" shall mean an assembly consisting of two independently operating approved check valves together with hydraulically operating, mechanically independent, pressure differential relief valve located between the check valves and below the first check valve. These units shall be located between two, tightly closing resilient seated shut-off valves as an assembly and equipped with properly located resilient seated test cocks. "Reduced pressure principle detector assembly" shall mean a specially designed assembly composed of a line-size approved reduced pressure principle backflow prevention assembly with a bypass containing a water meter and approved reduced pressure principle backflow prevention assembly specifically designed for such application. The meter shall register accurately for very low flow rates of flows up to three gallons per minute and shall show registration for all flow rates. This assembly shall be used to protect against non-health and health hazards and used for internal protection. "Repurified water" shall mean a high quality product of a multiple-stage advanced treatment process that cleans and disinfects domestic wastewater. Chlorine is then added to produce a residual which helps to maintain its freshness. Repurified water is distributed through a separate system of special repurified water mains at a pressure somewhat lower than the potable water. Although the repurified water produced by Murfreesboro is virtually indistinguishable from potable water, it is not intended for use as drinking water. A listing of other restrictions and plumbing requirements is contained in the Murfreesboro Repurified Water Usage Policies and Procedures Manual. "Service connection" shall mean the point of delivery to the Customer's water system; the terminal end of a service connection from the public water system where the Department loses jurisdiction and control over the water. Service connection shall include connections to fire hydrants and all other temporary or emergency water service connections made to the public water system. "State" shall mean The State of Tennessee, Tennessee Department of Environment and Conservation, Division of Water Supply. "Survey" shall mean an evaluation of a premise by a water system performed for the determination of actual or potential cross-connection hazards and the appropriate backflow prevention needed. "Water system" shall mean the water system operated, whether located inside or outside, the corporate limits of the City which water system consists of two parts, the Utility System and the Customer System. (A) The Utility System shall consist of the facilities for the production, treatment, storage, and distribution of water, and shall include all those facilities of the water system under the complete control of the Department, up to the point where the Customer's System begins (i.e. downstream of the water meter). (B) The Customer System shall include those parts of the facilities beyond the termination of the Department's distribution system that are utilized in conveying water to the point of use.

(Ord. No. 93-O-43 § 1, 04-01-93; Ord. No. 08-O-23 § 2, 07-10-08; Ord. No. 09-O-23 §§ 1, 2, 06-18-09; Ord. No. 18-O-47, § 7, 8-16-18)

Ask a question about Murfreesboro law

Corpus searches the Murfreesboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.