Section 33-35 - Building sewers and connections.
(A) No person shall uncover, make any connection with or opening into, use, alter or disturb any public sewer or appurtenance thereof without first paying the appropriate connection fees and obtaining a written permit from the City Building and Codes Department. (B) All costs and expense incident to the installation and connection of the building sewer shall be borne by the owner. The owner shall indemnify the City from any loss or damage that may directly or indirectly be occasioned by the installation of the building sewer. (C) A separate and independent building sewer shall be provided for every building, except where one building stands at the rear of another or an interior lot and no private sewer is available or can be constructed to the rear building through an adjoining alley, court, yard or driveway, the building sewer from the front building may be extended to the rear building and the whole considered as one building sewer. (D) Old building sewers may be used in connection with new buildings only when they are found, on examination and test by the Director, to meet all requirements of this chapter. (E) The building sewer piping material shall comply with the edition of the International Plumbing Code or International Residential Code for One or Two Family Dwellings then adopted by the City, whichever applies. (F) The size and slope of the building sewer shall be subject to the approval of the Director. In general, the building sewer shall be the same size as the service branch but in no event less than 4 in. in diameter. The slope of the building sewer shall in no event be less than one-eighth inch per foot. (G) Wherever possible the building sewer shall be brought to the building at an elevation below the basement floor. The building sewer shall be laid at uniform grade and in straight alignment insofar as possible. Changes in direction shall be made only with properly curved pipe and fittings. (H) (1) In all buildings in which any building drain is too low to permit gravity flow to the public sewer, or where any fixture (e.g. shower drain, or floor drain) served is below the level of the street, the owners and tenants shall be required to execute a Release and Indemnification Agreement holding the City harmless with regard to personal injury, wrongful death and property damages pursuant to a document prepared by or in conformance with a form approved by the City Attorney. In all buildings in which any building drain is too low to permit gravity flow to the public sewer, sanitary sewage carried by such drain shall be lifted by an approved artificial means and discharged to the building sewer which gravity flows to the public sewer. (2) Prior to approval of a subdivision plat or site plan, the following note must appear on the plat or site plan: NOTE: Any house or structure with a building drain to the public sanitary sewer with a floor elevation at any point below the elevation of the center of the street may be subject to Murfreesboro City Code Section 33-35(I)(1) which requires the owner(s) to execute a Release and Indemnification Agreement in favor of the City as a prerequisite to connecting to water and/or sewer services. (I) All excavation required for the installation of a building sewer shall be open trench work unless otherwise approved in writing by the Director. Pipe laying, embedment and backfill shall be performed in accordance with ASTM C-12, latest revision, for clay pipe; and ASTM 2321, latest revision, for all PVC pipe. All PVC pipe shall be placed in crushed stone embedment at a minimum of 6 inches below and above the pipe. (J) All building sewer joints and connections shall comply with the International Plumbing Code or the International Residential Code for One or Two Family Dwellings, whichever applies. (K) The building sewer shall be connected into the public sewer at the curb or property line if a service branch is available at a suitable location. Where no properly located service branch is available, a neat hole may be cut into the main line of the public sewer and a suitable wye or tee saddle installed to receive the building sewer. The invert of the building sewer at such point of connection with a wye saddle shall be in the upper quadrant of the main line of the public sewer. A neat workmanlike connection shall be made and the saddle made secure and watertight by encasement in concrete. (L) The applicant for the building sewer permit shall notify the Director of the Building and Codes Department when the building sewer is ready for inspection and connection to the public sewer. The connection shall be made under the supervision of the Director of the Water Resources Department. (M) All excavations for building sewer installation shall be adequately guarded with barricades and lights so as to protect the public from hazard on streets, sidewalks, parkways and other public property satisfactory to the City.
(Ord. No. 75-1 §§ 1-4, 02-27-75; Ord. No. 75-9 § 1, 04-24-75; Ord. No 82-2 § 1, 03-18-82; Ord. No. 90-47 § 3, 10-11-90; Ord. No. 97-O-66 § 1, 01-08-98; Ord. No. 01-O-35 § 5, 10-18-01; Ord. No. 02-O-08 §§ 2-5, 01-24-02; Ord. No. 08-O-22 §§ 6-10, 07-01-10; Ord. No. 18-O-47, § 7, 8-16-18)
Ask a question about Murfreesboro law
Corpus searches the Murfreesboro sections it holds and shows the ones that match, with their citations. Free, no sign-in.