Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Plumbing Chapter, § 1.05

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/6ef99d89-0319-4fa4-a1c4-d993a8370a30

Section 1.05 Amendments, Additions and Deletions – IPC

The adoption by reference of the International Plumbing Code, as provided in Section 1.02 hereof, is made subject to the following terms and is modified and amended as follows: A. By the addition thereto of Article II, et seq. of this Chapter. B. By the amendment of the following sections of the International Plumbing Code: 1. Adoption of Appendix C, entitled Structural Safety. 2. The deletion of Section 101, entitled SCOPE AND GENERAL REQUIREMENTS, in its entirety. 3. The amendment of Section 102.8, entitled Referenced codes and standards, to read as follows: 102.8 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 15 and such codes and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference. Where the requirements of reference standards or manufacturer’s installation instructions do not conform to minimum provisions of this code, the provisions of this code shall apply. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or the National Electrical Code (NEC) shall mean the Electrical Code as adopted. Exception: Where enforcement of a code provision would violate the conditions of the listing of the equipment or appliance, the conditions of the listing and the manufacturer’s installation instruction shall apply. 4. The amendment of Section 103.1, entitled Creation of agency, by retitling and amending the section to read as follows. 103.1 General. The executive official in charge of plumbing inspection shall be the Code Official, also known as the Building Official or Administrative Authority. 5. The amendment of Section 104.4, entitled Right of entry, to read as follows: 104.4 Right of entry. Whenever it is necessary to make an inspection to enforce the provisions of this chapter, or whenever the Code Official has reasonable cause to believe that there exists in any building or upon any premises any conditions or violations of this chapter that make the building or premises unsafe, unsanitary, dangerous or hazardous, the Code Official shall have the authority to enter the building or premises at all reasonable times to inspect or to perform the duties imposed upon the Code Official by this chapter. If such building or premises is occupied, the Code Official shall present credentials to the occupant and request entry. If such building or premises is unoccupied, the Code Official shall first make a reasonable effort to locate the owner or other person having charge or control of the building or premises and request entry. If entry is refused, or if no owner or other person having charge or control of the building or premises can be located, the Code Official shall have recourse to every remedy provided by law to secure entry. 6. The amendment of Section 106.1, entitled Where required, to read as follows: 106.1 When required. Any owner, authorized agent or contractor who desires to construct, enlarge, alter, repair, move, demolish or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any plumbing system, the installation of which is regulated by this code, or to cause any such work to be done, shall first make application to the code official and obtain the required permit for the work. A permit may only be issued to a registrant as provided in Article III of this Chapter. 7. The deletion of Section 106.4, entitled By whom application is made, in its entirety. 8. The amendment of Section 106.5, entitled Permit issuance, to read as follows: 106.5 Permit issuance. The application, construction documents and other data filed by an applicant for permit shall be reviewed by the code official. If the code official finds that the proposed work conforms to the requirements of this code and all laws and ordinances applicable thereto, and that the fees as established by resolution of the City Council from time to time have been paid in full, a permit shall be issued. 9. The amendment of Section 106, entitled PERMITS, to add Section 106.6, et seq, which shall read as follows: 106.6 Fees and refunds. Any person, firm or corporation desiring a permit as required by this Plumbing Code shall, at or before the time of permit issuance, pay a fee as specified in the fee structure as approved by the City Council of the City of Arlington by resolution and which may be amended from time to time by said City Council. 106.6.1 Any person who commences any work on a plumbing system before obtaining the necessary permits shall be subject to 100 percent of the usual permit fee in addition to the required permit fees. 106.6.2 Standards. The fee standards as set out in the Construction Chapter shall apply to calculations and fees. 106.6.3 Refund of a fee submitted for any administrative action under this Chapter shall be made in accordance with Section 4.12 of the "Construction" Chapter. 106.6.4 When the replacement of a contractor occurs during a project for which a permit has been issued pursuant to this Mechanical Code, the Administrative Authority may prorate the amount of the permit fee for the new contractor based on said Administrative Authority's determination of the percentage of work remaining. 106.6.5 When it is determined after a permit has been issued that the scope of work is to be significantly changed, the Administrative Authority may authorize and require that appropriate adjustments be effected to the permit fee. Any increase in the permit fee shall be paid prior to performing any part of such increased scope of work. Any decrease in the permit fee which is based on previously approved work which will not be performed as earlier defined may be refunded in the amount of fifty percent (50%) of the fee represented by the percentage of work not to be performed; provided, however, that determination of such percentage and specific authorization of such refund shall be issued by the Administrative Authority. Refunds, if made, shall be made to the original permittee in accordance with Article IV of the Construction Chapter. 10. The deletion of Section 109, entitled FEES, in its entirety. 11. The amendment of Section 112.1, entitled General, by adding an exception which shall read as follows: Exception: The owner of a property may choose to contract with a Third Party Provider that is properly registered with the City for inspections. Inspections performed by Third Party Organizations are subject to the terms of the program as authorized by resolution of the City Council of the City of Arlington. A Third Party Provider shall not be authorized to grant a Certificate of Occupancy. 12. The amendment of Section 112.4, entitled Testing, to read as follows: 112.4 Testing. Plumbing work and systems shall be tested as required in Section 312 and in accordance with Sections 112.4.1 through 112.4.3. Tests shall be made by the permit holder and may be observed by the code official. 13. The deletion of Section 113, MEANS OF APPEALS, in its entirety. 14. The deletion of Section 114, BOARD OF APPEALS, in its entirety. 15. The amendment of Section 115.2, entitled Notice of violation, to read as follows: 115.2 Notice of violation. The Code Official is authorized to serve a notice of violation or order to the person responsible for the erection, installation, alteration, extension, repair, removal or demolition of plumbing work in violation of the provisions of this Chapter, or in violation of a detail statement or the approved construction documents thereunder, or in violation of a permit or certificate issued under the provisions of this Chapter. Such order shall direct the discontinuance of the illegal action or condition and the abatement of the violation. 16. The deletion of Section 115.3, entitled Prosecution of violation, in its entirety. 17. The amendment of Section 115.4, entitled Violation penalties, to read as follows: 115.4 Violation penalties. It shall be unlawful for any person, firm or corporation to erect, construct, enlarge, alter, repair, move, improve, remove, convert or demolish, equip, use or maintain any plumbing work or other work or cause or permit the same to be done in violation of this Chapter. When not otherwise specified, each day that prohibited conditions are maintained shall constitute a separate offense. If the definition of an offense under this Chapter does not prescribe a culpable mental state, then a culpable mental state is not required. Such offense shall be punishable by a fine not to exceed Five Hundred Dollars and No Cents ($500.00). Although not required, if a culpable mental state is in fact alleged in the charge of the offense and the offense governs fire safety, zoning, or public health and sanitation, including dumping of refuse, such offense shall be punishable by a fine not to exceed Two Thousand Dollars and No Cents ($2,000.00). If the definition of an offense under this Chapter prescribes a culpable mental state and the offense governs fire safety, zoning, or public health and sanitation, including dumping of refuse, then a culpable mental state is required and the offense shall be punishable by a fine not to exceed Two Thousand Dollars and No Cents ($2,000.00). The issuing or granting of a permit or approval of plans and specifications by the City shall not be deemed or construed to be a permit for, or an approval of, any violation of any of the provisions of this Code or any other ordinance of the City. No permit presuming to give authority to violate or cancel the provisions of this Code, or any other ordinance of the City, shall be valid, except insofar as the work or use which is authorized is lawful. The issuing or granting of a permit or approval of plans by the City shall not prevent the Administrative Authority from thereafter requiring the correction of errors in said plans and specifications or from preventing construction operations being carried on thereunder when in violation of this Code or of any other ordinance of the City, or from revoking any certificate of approval when issued in error. 18. The amendment of Section 115.5, entitled Abatement of Violation, by retitling and amending the section to read as follows: 115.5 Stop work orders. Any work is being done contrary to the provisions of this Code, the Administrative Authority may order the work stopped by notice in writing served on any persons engaged in the doing or causing such work to be done. Any such person shall forthwith stop such work until: a. He or she is authorized by the Administrative Authority to proceed with the work; or b. An appeal perfected pursuant to Section 2.03 has resulted in a waiver of the condition causing the stop order, or a finding that there is no cause for a stop order. Failure to stop such work, in addition to penalties and remedies elsewhere set forth, shall void any appeal. 19. The deletion of Section 116, entitled STOP WORK ORDER, in its entirety. 20. The amendment of Section 202, entitled GENERAL DEFINITIONS, by amending the definition of "Code Official" and adding new definitions, which shall read as follows: BUILDING CODE. Building Code shall mean the International Building Code and the International Residential Code as adopted by this jurisdiction. CODE OFFICIAL. The officer or other designated authority charged with the administration and enforcement of this code, or a duly authorized representative. For the purpose of this code, the Code Official shall be the Building Official or designee. ELECTRICAL CODE. Electrical Code shall mean the National Electrical Code as adopted by this jurisdiction. For the purpose of this code, all references to NFPA 70 shall be assumed to mean the Electrical Code as defined herein. ENERGY CODE. Energy Code shall mean the International Energy Conservation Code as adopted by this jurisdiction. FIRE PREVENTION CODE (FIRE CODE). Fire Prevention Code shall mean the International Fire Code as adopted by this jurisdiction. MECHANICAL CODE. Mechanical Code shall mean the International Mechanical Code as adopted by this jurisdiction. PLUMBING CODE. Plumbing Code shall mean the International Plumbing Code as adopted by this jurisdiction. SHALL. Shall, as it applies to an act or duty to be performed by the Code Official pursuant to any section of the Code, is discretionary. Its use in all other applications in this Code shall be mandatory. 21. The amendment of Section 305.1, entitled Protection against contact, to read as follows: 305.1 Protection against contact. Metallic piping, except for cast iron, ductile iron and galvanized steel, shall not be placed in direct contact with steel framing members, concrete or cinder walls and floors or other masonry. Metallic piping shall not be placed in direct contact with corrosive soil. Where sheathing is used to prevent direct contact, the sheathing shall have a thickness of not less than 0.008 inch (8 mil) (0.203 mm) and the sheathing shall be made of approved material. Where sheathing protects piping that penetrates concrete or masonry walls or floors, the sheathing shall be installed in a manner that allows movement of the piping within the sheathing. 22. The amendment of Section 305.4, entitled Freezing, to read as follows: 305.4 Freezing. Water, soil or waste pipes shall not be installed outside of a building, in attics or crawl spaces, concealed in outside walls, or in any other place subjected to freezing unless adequate provision is made to protect such pipe from freezing. Piping in unheated attic, crawl space areas, and exterior walls shall be protected with not less than three-quarters of an inch (3/4") (19.05 mm) thickness of approved pipe insulation. Joints in insulation shall be sealed per manufacturer installation requirements. The use of tape for joining the insulation is prohibited unless approved per manufacturer. Water service piping shall be not less than 12 inches (305 mm) deep or less than 6 inches (152 mm) below the frost line. 23. The amendment of Section 305.4.1, entitled Sewer depth, to read as follows: 305.4.1 Sewer depth. Building sewers shall be a minimum of 12 inches (304 mm) below grade. 24. The amendment of Section 306, entitled TRENCHING, EXCAVATION AND BACKFILL, by adding Section 306.2.4, entitled Plastic sewer and DWV piping installation, which shall read as follows: 306.2.4 Plastic sewer and DWV piping installation. Plastic sewer and DWV piping installed underground shall be installed in accordance with the manufacturer’s installation instructions. Trench width shall be controlled to not exceed the outside the pipe diameter plus 16 inches or in a trench which has a controlled width equal to the nominal diameter of the diameter of the piping multiplied by 1.25 plus 12 inches. The piping shall be bedded in 4 inches of granular fill and then backfilled compacting the side fill in 6-inch layers on each side of the piping. The compaction shall be to minimum of 85 percent standard proctor density and extend to a minimum of 6 inches above the top of the pipe. 25. The amendment of Section 312.10.1, entitled Inspections, to read as follows: 312.10.1 Inspections. When required by the Water Resources Services Division, annual inspections shall be made of all backflow prevention assemblies and air gaps to determine whether they are operable. In the absence of local provisions, the owner is responsible to ensure that inspections are performed annually. 26. The amendment of Section 312.10.2, entitled Testing, to read as follows: 312.10.2 Testing. Reduced pressure principle backflow preventer assemblies, double check-valve assemblies, double-detector check valve assemblies and pressure vacuum breaker assemblies shall be tested at the time of installation, immediately after repairs or relocation and when otherwise required by the Water Resources Services Division. The testing procedure shall be performed in accordance as required by the Water Resources Services Division. In the absence of local provisions, the owner is responsible to ensure that testing is performed at least annually and is done in accordance with one of the following standards: ASSE 5013, ASSE 5015, ASSE 5020, ASSE 5047, ASSE 5048, ASSE 5052, ASSE 5056, CSA B64.10 OR CAS B64.10.1 27. The amendment of Section 314.2.1, entitled Condensate disposal, to read as follows: 314.2.1 Condensate disposal. Condensate from all cooling coils and evaporators shall be conveyed from the drain pan outlet to a permanently wet p-trap. Condensate shall not discharge in a publicly exposed area such as into a street, alley, sidewalk or other areas so as to cause a nuisance Exceptions: 1. Condensate may discharge directly to a roof drain that connects to an underground storm sewer system, 2. Condensate may discharge directly onto roofs covered with membrane type roof coverings where the condensate will drain to a roof drain that connects to an underground storm sewer system, 3. Condensate may discharge to a landscaped area containing flowers and other bedding plants other than turf. There must be five square feet of landscaped area for each ton of refrigeration, or 4. Condensate may discharge to a French drain consisting of a pit excavated below grade that is not less than 24 inches (610 mm) in any dimension. The pit shall be filled with coarse gravel and the drainpipe shall extend into the pit and be securely anchored. A single drain shall not receive the condensate discharge of more than 10 tons nominal of combined cooling capacity. The pit shall be covered with sod after inspection. The French drain shall not be located so that it will receive direct discharge from a roof or a downspout. 28. The amendment of Section 403.2, entitled Separate facilities, by deleting Exception 6, in its entirety. 29. The amendment of Section 403, entitled MINIMUM PLUMBING FACILITIES, by adding Section 403.7, et seq., which shall read as follows: 403.7 Additional fixtures for food preparation facilities. In addition to the fixtures required in this Chapter, all food service facilities shall be provided with additional fixtures set out in this section. 403.7.1 Hand washing lavatory. At least one hand washing lavatory shall be provided for use by employees that is accessible from food preparation, food dispensing and warewashing areas. Additional hand washing lavatories may be required based on convenience of use by employees. 403.7.2 Service sink. In new or remodeled food service establishments, at least one service sink or one floor sink shall be provided so that it is conveniently located for the cleaning of mops or similar wet floor cleaning tools and for the disposal of mop water and similar liquid waste. The location of the service sink(s) and/or mop sink(s) shall be approved by the City of Arlington health department. 30. The amendment of Section 413.4, entitled Public laundries and central washing facilities, by retitling and amending to read as follows: 413.4 Required location for floor drains Public laundries and central washing facilities. Floor drains shall be installed in the following areas: 1. In public laundries and in the central washing facilities of multiple family dwellings, the rooms containing automatic clothes washers shall be provided with floor drains located to readily drain the entire floor area. Such drains shall have a minimum outlet of not less than 3 inches (76 mm) in diameter. 2. Commercial kitchens. In lieu of floor drains in commercial kitchens, the Code Official may accept floor sinks. 3. Public restrooms. 31. The amendment of Section 417, entitled GARBAGE CAN WASHERS, by adding Section 417.3, entitled Rainwater, which shall read as follows: 417.3 Rainwater. The receptacle receiving waste from the wash area shall be protected in such a manner as to prevent the intrusion of rainwater. The location of the receptacle is subject to the approval of the Water Resource Services Division of Water Utilities. 32. The amendment of Section 424, entitled URINALS, by adding Section 424.3, entitled Surrounding material, to read as follows: 424.3 Surrounding material. Wall and floor space to point 2 feet (610 mm) in front of a urinal lip and 4 feet (1219 mm) above the floor and at least 2 feet (610 mm) to each side of the urinal shall be waterproofed with a smooth, readily cleanable, hard, nonabsorbent material. 33. The amendment of Section 502.3, entitled Water heaters installed in attics, to read as follows: 502.3 Water heaters installed in attics. Attics containing a water heater shall be provided with an opening and unobstructed passageway large enough to allow removal of the water heater. The passageway shall be not less than 30 inches (762 mm) in height and 22 inches (559 mm) in width and not more than 20 feet (6096 mm) in length when measured along the centerline of the passageway from the opening to the water heater. The passageway shall have continuous solid flooring not less than 24 inches (610 mm) in width. A level service space of not less than 30 inches (762 mm) in length and 30 inches (762 mm) in width shall be present at the front or service side of the water heater. The clear access opening dimensions shall be not less than 20 inches by 30 inches (508 mm by 762 mm) where such dimensions are large enough to allow removal of the water heater. A walkway to an appliance shall be rated as a floor as approved by the building official. As a minimum, for access to the attic space, provide one of the following: 1. A permanent stair. 2. A pull down stair with a minimum 300 lb (136 kg) capacity. 3. An access door from an upper floor level. 4. Access Panel may be used in lieu of items 1, 2, and 3 with prior approval of the code official due to building conditions. Exceptions: 1. The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening. 2. Where the passageway is not less than 6 feet high (1829 mm) for its entire length, the passageway shall not be limited in length. 34. The amendment of Section 502, entitled INSTALLATION, by adding Section 502.3.1, entitled Electrical requirements, which shall read as follows: 502.3.1 Electrical requirements. A lighting fixture controlled by a switch located at the required passageway opening and a receptacle outlet shall be provided at or within 25 feet (7619 mm) of the equipment location in accordance with the electrical code. 35. The amendment of Section 502, entitled INSTALLATION, by adding Section 502.6, entitled Water heaters above ground or floor, which shall read as follows: 502.6 Water heaters above ground or floor. When the attic, roof, mezzanine or platform in which a water heater is installed is more than eight (8) feet (2438 mm) above the ground or floor level, it shall be made accessible by a stairway or permanent ladder fastened to the building. Exception: A maximum 10-gallon water heater (or larger with approval) is capable of being accessed through a lay-in ceiling and the water heater installed is not more than ten (10) feet (3048 mm) above the ground or floor level and may be reached with a portable ladder. 36. The amendment of Section 502, entitled INSTALLATION, by adding Section 502.7, entitled Illumination and electrical outlet requirements, which shall read as follows: 502.7 Illumination and electrical outlet requirements. Whenever the mezzanine or platform is not adequately lighted and/or access to a receptacle outlet is not available from the main level within 25′ of water heater, lighting and a receptacle outlet shall be provided in accordance with Section 502.1. 37. The amendment of Section 608.17.5, entitled Connection to lawn irrigation systems, to read as follows: 608.17.5 Connections to lawn irrigation systems. The potable water supply to lawn irrigation systems shall be protected against backflow by an atmospheric-type vacuum breaker, a pressure-type vacuum breaker, a double-check assembly or a reduced pressure principal backflow preventer. A valve shall not be installed downstream from an atmospheric vacuum breaker. Where chemicals are introduced into the system, the potable water supply shall be protected against backflow by a reduced pressure principal backflow preventer. 38. The amendment of Section 703.6, entitled Combined sanitary and storm public sewer, by deleting in its entirety. 39. The amendment of Section 704, entitled DRAINAGE PIPING INSTALLATION, by adding Section 704.5, entitled Single stack fittings, to read as follows: 704.5 Single stack fittings. Single stack fittings with internal baffle, PVC schedule 40 or cast-iron single stack shall be designed by a registered engineer and comply to a national recognized standard. 40. The amendment of Section 712, entitled SUMPS AND EJECTORS, by adding Section 712.4.3, entitled Dual Pump System, to read as follows: 712.4.3 Dual Pump System. All sumps shall be automatically discharged and, when in any "public use" occupancy where the sump serves more than 10 fixture units, shall be provided with dual pumps or ejectors arranged to function independently in case of overload or mechanical failure. For storm drainage sumps and pumping systems, see Section 1113. 41. The amendment of Section 713, entitled COMPUTERIZED DRAINAGE DESIGN, to retitle Section 713 as ENGINEERED COMPUTERIZED DRAINAGE DESIGN. 42. The amendment of Section 713.1, entitled Design of drainage system, to read as follows: 713.1 Design of drainage system. The sizing, design and layout of the drainage system shall be permitted to be designed by a registered engineer using approved computer design methods. 43. The amendment of Section 802.4.3, entitled Standpipes, to read as follows: 802.4.3 Standpipes. Standpipes shall be individually trapped. Standpipes shall extend a minimum of 18 inches (457mm) and a maximum of 42 inches (1066mm) above the trap weir. Access shall be provided to all standpipe traps and drains for rodding. The p-trap on the standpipe for a washing machine shall not be installed below the floor. 44. The amendment of Section 803, entitled SPECIAL WASTES, by adding Section 803.3, entitled Backwash from swimming pools, to read as follows: 803.3 Backwash from swimming pools. Any backwash from a swimming pool shall discharge into the sanitary sewer system or other approved methods as allowed by the Texas Commission on Environmental Quality and the administrative authority. An indirect connection shall be made by means of an air gap discharging into a tail piece with the opening installed a minimum of 6 inches (152 mm) above adjacent grade. A minimum size 3-inch (76 mm) p-trap installed not less than 12 inches (304 mm) below grade may connect to the yard cleanout riser by a sanitary tee fitting. 45. The amendment of Section 903, entitled VENT TERMINALS, by retitling and amending the section to read as follows: SECTION 903 ROOF EXTENSIONS 903.1 Roof extension 903.1.1 Roof extension unprotected. Open vent pipes that extend through a roof shall terminate not less than six (6) inches (152 mm) above the roof. Where a roof is to be used for assembly or as a promenade, observation deck, sunbathing deck or similar purposes, open vent pipes shall terminate not less than 7 feet (2134 mm) above the roof. 46. The amendment of Section 1003.2, entitled Approval, to read as follows: 1003.2 Approval. All requirements regarding the size, type, location and listing of interceptors and/or separators shall be regulated by the Water Utilities Department. All installations of interceptors and/or separators shall be inspected by the code official. 47. The amendment of Section 1003, entitled INTERCEPTORS AND SEPARATORS, by adding Section 1003.11, entitled Test wells, to read as follows: 1003.11 Test wells. The size, type, location and listing of test wells shall be regulated by the Water Resources Division of the Water Utilities Department. A test well shall be installed on the outlet of each individual interceptor and/or separator. The installation of a test well shall include a retaining device as specified by the Water Resources Services Division of the Water Utilities Department. All installations of test wells shall be inspected by the code official. 48. The amendment of Section 1109, entitled COMBINED SANITARY AND STORM PUBLIC SEWER, by deleting in its entirety. 49. The amendment of Section 1202.1, entitled Nonflammable medical gases, by deleting Exceptions 1 and 2. 50. The amendment of Section 1202, entitled MEDICAL GASES, by adding Section 1202.2, entitled Requirements for medical gas installations and installers, which shall read as follows: 1202.2 Requirements for medical gas installations and installers. All persons, firms or individuals must be registered with the City of Arlington as required by this code in order to install or alter medical gas installations. In order to be qualified to register as a medical gas installer, the Responsible Master Plumber must also hold a current Medical Gas Installation Endorsement as issued by the Texas State Board of Plumbing Examiners. All individuals installing and/or altering piping systems used to transport gases for medical purposes shall be a master or journeyman plumber that also holds a current Medical Gas Installation Endorsement as issued by the Texas State Board of Plumbing Examiners. 51. The amendment of Section 1202, entitled MEDICAL GASES, by adding Section 1202.3, entitled Testing and certification of medical gas systems, which shall read as follows: 1202.3 Testing and certification of medical gas systems. All testing and certification of medical gas piping systems shall be performed by an individual that is certified to do so. All testing and certification shall be done in accordance with NFPA 99C. A City of Arlington "Medical Gas Piping System Installation Compliance Certificate" and "Medical Gas Piping System Verification Certificate of Compliance" shall be submitted to the code official at or prior to requesting a final inspection.

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.