§ 1.06 — Amendments, Additions and Deletions - IFGC

Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Plumbing Chapter, § 1.06

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/873d6112-277e-43ab-9574-3f385ccfa4f3

Section 1.06 Amendments, Additions and Deletions - IFGC

The adoption by reference of the International Fuel Gas Code, as provided in Section 1.02, is made subject to the following terms and is modified and amended as follows: A. By the addition of Article II, et seq., of this Chapter. B. By the amendment of the following sections of the IFGC: 1. The adoption of IFGC Appendices A, B and C. 2. The deletion of IFGC Section 101.1, entitled Title, and Section 101.4, entitled Purpose, in their entirety. 3. The amendment of IFGC Section 102.8, entitled Referenced codes and standards, to read as follows: 102.8 Referenced codes and standards. The codes and standards referenced herein shall be those that are listed in Chapter 8 and such codes, when specifically adopted, and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between provisions of this code and the referenced standards, the provisions of this code shall apply. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or National Electrical Code (NEC) shall mean the Electrical Code as adopted. Exception: Where enforcement of a code provision would violate the conditions of the listing of the equipment or appliance, the conditions of the listing and the manufacturer’s installation instructions shall apply. 4. The amendment of Section 103.1, entitled General, to read as follows: 103.1 General. The executive official in charge of fuel gas inspection shall be known as the Code Official. 5. The deletion of Section 103.2, entitled Appointment, in its entirety. 6. The amendment of Section 104.1, entitled General, to read as follows: 104.1 General. The code official shall enforce all of the provisions of the ordinance governing the fuel gas piping and shall act on any question relative to the installation, alteration, repair, maintenance or operation of systems, except as otherwise specifically provided for by statutory requirements or as provided for in Sections 104.2 through 104.7. 7. The amendment of Section 104.2, entitled Applications and permits, et seq., to read as follows: 104.2 Applications and permits. A separate permit shall be obtained for each building or structure under the conditions stated in Article III, Section 3.01, et.seq., of this Chapter. 104.2.1 A person commits an offense if he/she allows another to do or cause to be done any work under a permit other than the permittee or an employee of the permittee. 104.2.2 After issuing a permit or granting approval of plans and specifications, the code official shall remain empowered to: 104.2.2.1 Require the correction of errors in plans and specifications, 104.2.2.2 Prevent the commencement or continuation of construction operations conducted under such plans and specifications when such operations are in violation of this Chapter or other ordinance. 104.2.3 Every permit issued under this Chapter shall expire by limitation and become null and void if the work is suspended or abandoned for a period of one hundred eighty (180) days. 8. The amendment of Section 104.4, entitled Right of Entry, to read as follows: 104.4 Right of entry. Whenever it is necessary to make an inspection to enforce the provisions of this chapter, or whenever the Code Official has reasonable cause to believe that there exists in any building or upon any premises any conditions or violations of this chapter that make the building or premises unsafe, unsanitary, dangerous or hazardous, the Code Official shall have the authority to enter the building or premises at all reasonable times to inspect or to perform the duties imposed upon the Code Official by this Chapter. If such building or premises is occupied, the Code Official shall present credentials to the occupant and request entry. If such building or premises is unoccupied, the Code Official shall first make a reasonable effort to locate the owner or other person having charge or control of the building or premises and request entry. If entry is refused, or if no owner or other person having charge or control of the building or premises can be located, the Code Official shall have the recourse to every remedy by law to secure entry. 9. The amendment of Section 106, entitled PERMITS, by adding Section 106.6, entitled Fees, which shall read as follows: 106.6 Fees. The standard for fee administration shall be as stated in IPC Section 106.6, as amended. 10. The deletion of Section 109, entitled FEES, in its entirety. 11. The deletion of Section 113, entitled MEANS OF APPEAL, in its entirety. 12. The deletion of Section 114, entitled BOARD OF APPEAL, in its entirety. 13. The amendment of Section 115.2, entitled Notice of violation, to read as follows: 115.2 Notice of violation. The Code Official is authorized to serve a notice of violation or order to the person responsible for the erection, installation, alteration, extension, repair, removal or demolition of work in violation of the provisions of this Chapter, or in violation of a detail statement or the approved construction documents thereunder, or in violation of a permit or certificate issued under the provisions of this Chapter. Such order shall direct the discontinuance of the illegal action or condition and the abatement of the violation. 14. The deletion of Section 115.3, entitled Prosecution of violation, in its entirety. 15. The amendment of Section 115.4, entitled Violation penalties, to read as follows: 115.4 Violation penalties. The provisions for violations of this code shall be as specified in IPC Section 115.4 at Section 1.05 of this Chapter. 16. The amendment of Section 115.5, entitled Stop work orders, to read as follows: 115.5 Stop work orders. The provisions for stop work orders shall be the same as Section 115.5 of the International Plumbing Code, as amended by this Chapter. 17. The amendment of Section 115.6, entitled Abatement of violation, to read as follows: 115.6 Abatement of violation. A fuel gas piping system found by the Code Official to be in violation of the Chapter is hereby declared to be a nuisance. The Code Official shall be empowered to abate such nuisances in the manner provided by Article IV of the "Nuisance" Chapter of the Code of the City of Arlington. 18. The deletion of Section 116, entitled STOP WORK ORDER, in its entirety. 19. The amendment of Section 306.3, entitled Appliances in attics, to read as follows: 306.3 Appliances in attics. Attics containing appliances shall be provided with an opening and unobstructed passageway large enough to allow removal of the largest appliance. The passageway shall be not less than 30 inches (762 mm) in height and 22 inches (559 mm) in width and not more than 20 feet (6096 mm) in length when measured along the centerline of the passageway from the opening to the appliance. The passageway shall have continuous solid flooring not less than 24 inches (610 mm) in width. A level service space of not less than 30 inches (762 mm) in length and 30 inches (762 mm) in width shall be present at the front or service side of the appliance. The clear access opening dimensions shall be not less than 20 inches by 30 inches (508 mm by 762 mm) where such dimensions are large enough to allow removal of the largest appliance. A walkway to an appliance shall be rated as a floor as approved by the building official. As a minimum, for access to the attic space, provide one of the following: 1. A permanent stair. 2. A pull down stair with a minimum 300 lb (136 kg) capacity. 3. An access door from an upper floor level. 4. Access Panel may be used in lieu of items 1, 2, and 3 with prior approval of the code official due to building conditions. Exceptions: 1. The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening. 2. Where the passageway is not less than 6 feet (1829 mm) high and 22 inches (559 mm) wide for its entire length, the passageway shall be not greater than 50 feet (15 250 mm) in length. 20. The amendment of Section 306.5, entitled Equipment and Appliances on Roofs or Elevated Structures, to read as follows: 306.5 Equipment and Appliances on Roofs or Elevated Structures. Where equipment requiring access or appliances are located on an elevated structure or the roof of a building such that personnel will have to climb higher than 16 feet (4877 mm) above grade to access, an interior or exterior means of access shall be provided. Exterior ladders providing roof access need not extend closer than 12 feet (2438 mm) to the finish grade or floor level below and shall extend to the equipment and appliances' level service space. Such access shall not require climbing over obstructions greater than 30 inches (762 mm) in height or walking on roofs having a slope greater than four units vertical in 12 units horizontal (33-percent slope). Such access shall not require the use of portable ladders. Where access involves climbing over parapet walls, the height shall be measured to the top of the parapet wall. 21. The amendment of Section 306.5.1, entitled Sloped Roofs, to read as follows: 306.5.1 Sloped Roofs. Where appliances, equipment, fans or other components that require service are installed on a roof having a slope of three units vertical in 12 units horizontal (25-percent slope) or greater and having an edge more than 30 inches (762 mm) above grade at such edge, a catwalk at least 16 inches in width with substantial cleats spaced not more than 16 inches apart shall be provided from the roof access to a level platform at the appliance. The level platform shall be provided on each side of the appliance to which access is required for service, repair or maintenance. The platform shall be not less than 30 inches (762 mm) in any dimension and shall be provided with guards. The guards shall extend not less than 42 inches (1067 mm) above the platform, shall be constructed so as to prevent the passage of a 21-inch-diameter (533 mm) sphere and shall comply with the loading requirements for guards specified in the International Building Code. Access shall not require walking on roofs having a slope greater than four units vertical in 12 units horizontal (33-percent slope). Where access involves obstructions greater than 30 inches (762 mm) in height, such obstructions shall be provided with ladders installed in accordance with Section 306.5 or stairways installed in accordance with the requirements specified in the International Building Code in the path of travel to and from appliances, fans or equipment requiring service. 22. The amendment of Section 306, entitled ACCESS AND SERVICE SPACE, by adding Section 306.7, entitled Water heaters above ground or floor, which shall read as follows: 306.7 Water heaters above ground or floor. When the attic, roof, mezzanine or platform in which a water heater is installed is more than eight (8) feet (2438 mm) above the ground or floor level, it shall be made accessible by a stairway or permanent ladder fastened to the building. 23. The amendment of Section 401.5, entitled Identification, by adding a second paragraph, which shall read as follows: Both ends of each section of medium pressure gas piping shall identify its operating gas pressure with an approved tag. The tags are to be composed of aluminum or stainless steel and the following wording shall be stamped into the tag: "WARNING 1/2 to 5 psi gas pressure Do Not Remove" 24. The amendment of Section 401.7, entitled Piping meter identification requirements, to read as follows: 401.7 Piping meter identification requirements. Piping from multiple meter installations shall be marked with aluminum, brass or stainless steel tags indicating address served so the piping system supplied by each meter is readily identifiable. 25. The amendment of Section 402.3, entitled Sizing, by adding an exception to read as follows: Exception: Corrugated stainless steel tubing (CSST) shall be a minimum of ½". 26. The amendment of Section 404, entitled PIPING SYSTEM INSTALLATION, by adding Section 404.5.1, entitled Additional protection of CSST piping, which shall read as follows: 404.5.1 Additional protection of CSST piping. Where Corrugated Stainless Steel Tubing (CSST) piping is installed in exterior wall cavities, insulated wall cavities and/or insulated roof/ceiling assemblies, the CSST piping must be protected for its entire length with flexible metal conduit (per the UL-1 Standard or its equivalent), Schedule 40 steel pipe, or approved strike plates. The additional protection must extend a minimum of 18 inches (457.2 mm) beyond where the CSST piping exits the wall cavities and/or the roof/ceiling assemblies 27. The amendment of Section 404.12, entitled Minimum burial depth, to read as follows: 404.12 Minimum burial depth. Underground piping systems shall be installed a minimum depth of 18 inches (458 mm) top of pipe below grade. 28. The amendment of Section 404.12.1, Individual outdoor appliances, by deleting it in its entirety. 29. The amendment of Section 406.1, entitled General, to read as follows: 406.1 General. Prior to acceptance and initial operation, all piping installations shall be inspected and pressure tested to determine that the materials, design, fabrication, and installation practices comply with the requirements of this code. The permit holder shall make the applicable tests prescribed in Sections 406.1.1 through 406.1.5 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the piping system is ready for testing. The equipment, material, power and labor necessary for the inspections and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. 30. The amendment of Section 406, entitled INSPECTION, TESTING AND PURGING, by amending Section 406.4, entitled Test pressure measurement, et seq., which shall read as follows: 406.4 Test pressure measurement. Test pressure shall be measured with a monometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the scale is not greater than five times the test pressure. Spring type gauges do not meet the requirement of a calibrated gauge. 406.4.1 Test pressure. The test pressure to be used shall be no less than 1 1/2 times the proposed maximum working pressure, but no less than 3 psig (20 kPa gauge), or at the discretion of the Code Official, the piping and valves may be tested at a pressure of at least six (6) inches (152 mm) of mercury, measured with a manometer or slope gauge, irrespective of design pressure. Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe. For tests requiring a pressure of 3 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one half inches (3 ½"), a set hand, 1/10 pound incrementation and pressure range not to exceed 15 psi for tests requiring a pressure of 3 psig. For tests requiring a pressure of 10 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one-half inches (3 ½"), a set hand, a minimum of 2/10 pound incrementation and a pressure range not to exceed 50 psi. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa) (1/2 psi) and less than 200 inches of water column pressure (52.2 kPa) (7.5 psi), the test pressure shall not be less than ten (10) pounds per square inch (69.6 kPa). For piping carrying gas at a pressure that exceeds 200 inches of water column (52.2 kPa) (7.5 psi), the test pressure shall be not less than one and one-half times the proposed maximum working pressure. Diaphragm gauges used for testing must display a current calibration and be in good working condition. The appropriate test must be applied to the diaphragm gauge used for testing. 406.4.2 Test duration. Test duration shall be held for a length of time satisfactory to the Code Official, but in no case for less than fifteen (15) minutes. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa), the test duration shall be held for a length of time satisfactory to the Code Official, but in no case for less than thirty (30) minutes. 31. The amendment of Section 409.1, entitled General, by adding Section 409.1.4, entitled Valves in CSST installations, which shall read as follows: 409.1.4 Valves in CSST installations. Shutoff valves installed with corrugated stainless steel (CSST) piping systems shall be supported with an approved termination fitting, or equivalent support, suitable for the size of the valves, of adequate strength and quality, and located at intervals so as to prevent or damp out excessive vibration but in no case greater than 12-inches from the center of the valve. Supports shall be installed so as not to interfere with the free expansion and contraction of the system's piping, fittings, and valves between anchors. All valves and supports shall be designed and installed so they will not be disengaged by movement of the supporting piping. 32. The amendment of Section 410.1, entitled Pressure regulators, by adding a second paragraph and an exception which shall read as follows: Access to regulators shall comply with the requirements for access to appliances as specified in Section 306. Exception: A passageway or level service space is not required when the regulator is capable of being serviced and removed through the required attic opening. 33. The amendment of Section 621.2, entitled Prohibited use, to read as follows: 621.2 Prohibited use. One or more unvented room heaters shall not be used as the sole source of comfort heating in a dwelling unit. Exception: Existing approved unvented heaters may continue to be used in dwelling units, in accordance with the code provisions in effect when installed, when approved by the Code Official unless an unsafe condition is determined to exist as described in Section 108.7.

(Amend Ord 22-058, 11/01/22)

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.