§ 4.02 — Minimum Standards for Irrigation Plan Design
Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Irrigation Chapter, § 4.02
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/2756f868-8e49-4a9e-82b3-b11c5698b13d
Section 4.02 Minimum Standards for Irrigation Plan Design
A. An irrigator shall prepare an irrigation plan for each site where a new irrigation system will be installed. An approved paper copy of the irrigation plan must be on the job site at all times during the installation and inspection of the irrigation system. A drawing showing the actual installation of the system is due to each irrigation system owner after all new irrigation system installations. During the installation of the irrigation system, variances from the original plan may be authorized by the licensed irrigator if the variance from the plan does not: 1. diminish the operational integrity of the irrigation system; 2. violate any requirements of this ordinance; and 3. go unnoted in red on the irrigation plan. B. The irrigation plan must include complete coverage of the area to be irrigated. If a system does not provide complete coverage of the area to be irrigated, it must be noted on the irrigation plan. C. All irrigation plans used for construction must be drawn to scale. The plan must include, at a minimum, the following information: 1. the irrigator's seal, signature, and date of signing; 2. all major physical features and the boundaries of the areas to be watered; 3. a North arrow; 4. a legend; 5. the zone flow measurement for each zone; 6. location and type of each: a. controller; and b. sensor (for example, but not limited to, rain, moisture, wind, flow, or freeze); 7. location, type, and size of each: a. water source, such as, but not limited to a water meter and point(s) of connection; b. backflow prevention device; c. water emission device, including, but not limited to, spray heads, rotary sprinkler heads, quick-couplers, bubblers, drip, or micro-sprays; d. valve, including but not limited to, zone valves, master valves, and isolation valves; e. pressure regulation component; and f. main line and lateral piping. 8. the scale used; and 9. the design pressure. D. Final plans or other documents that will be archived must be submitted in an electronic format specified by the Director of Community Development and Planning ("CDP Director") as a condition to issuance of any type of permit, approval, or other action related to the final plans or documents. The City may provide an electronic conversion service for a fee in the amount set forth by City Council resolution. The CDP Director shall provide a schedule indicating which documents must be provided electronically, at which point during the approval process, and other information as necessary to implement an electronic archiving program.
(Amend Ord 10-014, 1/12/10)
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.