Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Irrigation Chapter, § 4.04

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/b62e3add-bae1-4231-b18f-9fde765464a0

Section 4.04 Backflow Prevention Methods and Devices

A. Any irrigation system that is connected to the potable water supply or reclaimed water supply must be connected in accordance with the Plumbing Chapter, Texas Commission on Environmental Quality rules, this chapter, and other relevant law. All backflow prevention assemblies shall be of a type and model approved by the Regulatory Authority. The backflow prevention device must be installed in accordance with the laboratory approval standards or if the approval does not include specific installation information, the manufacturer's current published recommendations. B. When an irrigation system is connected to a reclaimed water supply a double check backflow prevention assembly shall be installed immediately past the city meter just outside city right-of-way before any branch connections; and, the potable water supply to this site is now required to have an RPZ backflow device installed immediately past the city meter just outside the right-of-way before any branch connections. The devices will be tested upon installation and annually thereafter. C. If conditions that present a health hazard exist, one of the following methods must be used to prevent backflow; 1. An air gap may be used if: a. there is an unobstructed physical separation; and b. the distance from the lowest point of the water supply outlet to the flood rim of the fixture or assembly into which the outlet discharges is at least one inch or twice the diameter of the water supply outlet, whichever is greater. 2. Reduced pressure principle backflow prevention assemblies may be used if: a. the device is installed at a minimum of 12 inches above ground in a location that will ensure that the assembly will not be submerged; and b. drainage is provided for any water that may be discharged through the assembly relief valve. 3. Pressure vacuum breakers may be used if: a. no back-pressure condition will occur; and b. the device is installed at a minimum of 12 inches above any downstream piping and the highest downstream opening. Pop-up sprinklers are measured from the retracted position from the top of the sprinkler. 4. Atmospheric vacuum breakers may be used if: a. no back-pressure will be present; b. there are no shutoff valves downstream from the atmospheric vacuum breaker; c. the device is installed at a minimum of six inches above any downstream piping and the highest downstream opening. Pop-up sprinklers are measured from the retracted position from the top of the sprinkler; d. there is no continuous pressure on the supply side of the atmospheric vacuum breaker for more than 12 hours in any 24-hour period; and e. a separate atmospheric vacuum breaker is installed on the discharge side of each irrigation control valve, between the valve and all the emission devices that the valve controls. D. Backflow prevention devices used in applications designated as health hazards must be tested upon installation and annually thereafter. E. If there are no conditions that present a health hazard, double check valve backflow prevention assemblies may be used to prevent backflow if the device is tested upon installation and test cocks are used for testing only. F. If a double check valve is installed below ground: 1. test cocks must be plugged, except when the double check valve is being tested; 2. test cock plugs must be threaded, water-tight, and made of non-ferrous material; 3. a y-type strainer is installed on the inlet side of the double check valve; 4. there must be a clearance between any fill material and the bottom of the double check valve to allow space for testing and repair; and 5. there must be space on the side of the double check valve to test and repair the double check valve. G. If an irrigation system is connected to a potable water supply and requires major maintenance, alteration, repair, or service, the system must be connected to the potable water supply through an approved, properly installed backflow prevention method before any major maintenance, alteration, repair, or service is performed. H. If an irrigation system is connected to a potable water supply through a double check valve, pressure vacuum breaker, or reduced pressure principle backflow assembly and includes an automatic master valve on the system, the automatic master valve must be installed on the discharge side of the backflow prevention assembly. I. The irrigator shall ensure the backflow prevention device is tested by a licensed Backflow Prevention Assembly Tester that is registered with the City of Arlington prior to being placed in service and the test results shall be provided to the Regulatory Authority and to the irrigation system's owner or owner's representative within ten (10) business days of testing of the backflow prevention device.

(Amend Ord 11-020, 3/22/11)

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.