§ 5.02 — Specific Standards
Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Flood Damage Prevention Chapter, § 5.02
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/a4a166c9-cd6c-43bf-9f60-36c4fe009118
Section 5.02 Specific Standards
In all areas of special flood hazards where base flood elevation data has been provided as set forth in (i) Section 3.02, (ii) Section 4.02(8), or (iii) Section 5.03(3), the following provisions are required: (1) Residential Construction - new construction and substantial improvement of any residential structure shall have the lowest floor (including basement and finished garage), elevated two feet above the fully urbanized base flood elevation. A registered professional engineer, architect, or land surveyor shall submit a certification to the Floodplain Administrator that the standard of this subsection as proposed in Section 4.03(1)a is satisfied. (2) Nonresidential Construction - new construction and substantial improvements of any commercial, industrial or other nonresidential structure must have either: (a) The lowest floor (including basement, finished garage, and machinery or equipment servicing the structure) elevated two feet above the fully urbanized base flood level; or (b) The lowest floor (including basement, finished garage, and machinery or equipment servicing the structure), together with attendant utility and sanitary facilities, floodproofed and must: (i) Be designed so that below the level of two feet above the fully urbanized base flood level, the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and (ii) A registered professional engineer or architect must develop and/or review plans and specifications for the construction of the structure, and shall provide certification that the design and methods of construction are in accordance with accepted standards of practice as outlined in the provisions of Article V of this ordinance; and (iii) A registered professional engineer or architect must inspect the structure upon completion of construction, alterations, or installation of floodproofing devices and measures, and shall provide certification that the structure complies with the plans and specifications developed for the structure; and (iv) The record of design and construction certifications which include the specific elevation (in relation to mean sea level) to which such structures are floodproofed shall be maintained by the Floodplain Administrator. (v) Floodproofing may be allowed for critical systems essential to life safety, such as fire protection systems and emergency exit signs and emergency lighting, provided these are designed to function effectively when submerged or exposed to flooding with necessary safeguards, including watertight components, and backflow prevention. (3) Enclosures - new construction and substantial improvements with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access, or storage in an area other than a basement, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: (a) A minimum of two openings on separate walls having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. (b) The bottom of all openings shall be no higher than one foot above grade. (c) Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. (4) Manufactured Homes - (a) Require that all manufactured homes that are to be placed or substantially improved within Zone A on a community's FHBM or FIRM shall be installed using methods and practices which minimize flood damage. For the purposes of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable State and local anchoring requirements for resisting wind forces. (b) Require that manufactured homes that are to be placed or substantially improved within Zones A1-30, AH, and AE on the community's FIRM on sites (i) outside of a manufactured home park or subdivision, (ii) in a new manufactured home park or subdivision, (iii) in an expansion to an existing manufactured home park or subdivision, or (iv) in an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as a result of a flood, be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated two feet above the fully urbanized base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. (c) Require that manufactured homes that are to be placed or substantially improved within Zones A1-30, AH, and AE on the community's FIRM on sites in an existing manufactured home park or subdivision that are not subject to the provisions of paragraph (4) of this section be elevated to the higher of the following conditions: (i) the lowest floor of the manufactured home is two feet above the fully urbanized base flood elevation; or (ii) the manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above grade and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. (5) Recreational Vehicles - Require that recreational vehicles placed on sites within Zones A1-30, AH, and AE on the community's FIRM either: (a) be on the site for fewer than 180 consecutive days; or (b) be fully licensed and ready for highway use. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions; or (c) meet the permit requirements of Section 4.03(1), and the elevation and anchoring requirements for "manufactured homes" in paragraph (4) of this section.
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.
