§ 5.04 — Standards for Areas of Shallow Flooding (AO/AH Zones)
Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Flood Damage Prevention Chapter, § 5.04
Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/2cf51cd6-cdd3-4d3a-8027-fa2029f7ce09
Section 5.04 Standards for Areas of Shallow Flooding (AO/AH Zones)
Located within the areas of special flood hazard established in Section 3.02 are areas designated as shallow flooding. These areas have special flood hazards associated with flood depths of one to three feet where a clearly defined channel does not exist, where the path of flooding is unpredictable, and where velocity flow may be evident. Such flooding is characterized by ponding or sheet flow; therefore, the following provisions apply: (1) All new construction and substantial improvements of residential structures must have the lowest floor (including basement and finished garage) elevated two feet above the fully urbanized base flood elevation or the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM (at least three feet if no depth number is specified). (2) All new construction and substantial improvements of non-residential structures must: (a) have the lowest floor (including basement and finished garage) elevated two feet above the fully urbanized base flood elevation or the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM (at least three feet if no depth number is specified); or (b) together with attendant utility and sanitary facilities, be designed so that below the level of two feet above the specified base flood depth in an AO Zone, or below the level of two feet above the Base Flood Elevation in an AH Zone, the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads of effects of buoyancy. (3) A registered professional engineer or architect shall submit a certification to the Floodplain Administrator that the standards of this Section, as proposed in Section 4.03 are satisfied. (4) Require within Zones AH or AO adequate drainage paths around structures on slopes, to guide flood waters around and away from proposed structures.
Ask a question about Arlington law
Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.