Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Uniform Housing Code Chapter, § 503

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/c273ced2-846c-4dca-9cba-f8603efc6584

Section 503. Room Dimensions

(a) Ceiling Heights. Habitable space shall have a ceiling height of not less than seven feet (7'), six inches (6") except as otherwise permitted in this section. Kitchens, halls, bathrooms and toilet compartments may have a ceiling height of not less than seven feet (7') measured to the lowest projection from the ceiling. Where exposed beam ceiling members are spaced at less than forty-eight inches (48") on center, ceiling height shall be measured to the bottom of these members. Where exposed beam ceiling members are spaced at forty-eight inches (48") or more on center, ceiling height shall be measured to the bottom of the deck supported by these members provided that the bottom of the members is not less than seven feet (7') above the floor. If any room in a building has a sloping ceiling, the prescribed ceiling height for the room is required in only one-half (1/2) the area thereof. No portion of the room measuring less than five feet (5') from the finished floor to the finished ceiling shall be included in any computation of the minimum area thereof. If any room has a furred ceiling, the prescribed ceiling height is required in two-thirds (2/3) the area thereof, but in no case shall the height of the furred ceiling be less than seven feet (7'). (b) Floor Area. Every dwelling unit shall have at least one (1) room which shall have not less than one hundred-fifty (150) square feet of floor area. Other habitable rooms, except kitchens, shall have an area of not less than seventy (70) square feet. Where more than two (2) persons occupy a room used for sleeping purposes, the required floor area shall be increased at the rate of fifty (50) square feet for each occupant in excess of two (2). EXCEPTION: Nothing in this section shall prohibit the use of an efficiency living unit within an apartment house meeting the following requirements: 1. The unit shall have a living room of not less than two hundred-twenty (220) square feet of superficial floor area. An additional one hundred (100) square feet of superficial floor area shall be provided for each occupant of such unit in excess of two (2). 2. The unit shall be provided with a separate closet. 3. The unit shall be provided with a kitchen sink, cooking appliance and refrigeration facilities each having a clear working space of not less than fifty inches (50") in front. Light and ventilation conforming to this code shall be provided. 4. The unit shall be provided with a separate bathroom containing a water closet, lavatory and bathtub or shower. (c) Width. No habitable room other than a kitchen shall be less than seven feet (7') in any dimension. Each water closet stool shall be located in a clear space not less than thirty inches (30") in width and a clear space in front of the water closet stool of not less than twenty-four inches (24") shall be provided.

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.