Code of the City of Arlington, Texas (City Secretary chapter PDFs as posted 2026-11-07, each current through the ordinance named on its cover, with the City Secretary's adopted-not-yet-codified Ordinances 25-063, 25-069, 25-073, 25-074, 25-075, 25-084, 26-003, 26-004, 26-019, 26-024 and 26-027 applied; Anti-Discrimination chapter not included) · Arlington City Code, Uniform Housing Code Chapter, § 504

Corpus is an independent public-information project, not the official City of Arlington website. Stable reference: corpuslaw.us/code/e7b7be1b-7bbd-4e84-ace7-dbcd202de9d8

Section 504. Light and Ventilation

(a) Natural Light and Ventilation. All guest rooms, dormi-tories and habitable rooms within a dwelling unit shall be provided with natural light by means of exterior glazed openings with an area not less than one-tenth (1/10) of the floor area of such rooms with a minimum of ten (10) square feet. All bathrooms, water closet compartments, laundry rooms and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area not less than one- -twentieth (1/20) of the floor area of such rooms with a minimum of one and one-half (1½) square feet. All guest rooms, dormitories and habitable rooms within a dwelling unit shall be provided with natural ventila-tion by means of openable exterior openings with an area of not less than one-twentieth (1/20) of the floor area of such rooms with a minimum of five (5) square feet. (b) Origin of Light and Ventilation. Required exterior openings for natural light and ventilation shall open directly onto a street or public alley or a yard or court located on the same lot as the building. EXCEPTION: Required windows may open into a roofed porch where the porch: 1. Abuts a street, yard or court; and 2. Has a ceiling height of not less than seven feet (7'); and 3. Has the longer side at least sixty-five percent (65%) open and unobstructed. A required window in a service room may open into a vent shaft which is open and unobstructed to the sky and not less than four feet (4') in least dimension. No vent shaft shall extend through more than two (2) stories. For the purpose of determining light and ventilation requirements, any room may be considered as a portion of an adjoining room when one-half (1/2) of the area of the common wall is open and unobstructed and provides an opening of not less than one-tenth (1/10) of the floor area of the interior room or twenty-five (25) square feet, whichever is greater. (c) Mechanical Ventilation. In lieu of required exterior openings for natural ventilation, a mechanical ventila-tion system may be provided. Such system shall be capable of providing two (2) air changes per hour in all guest rooms, dormitories, habitable rooms and in public corridors. One-fifth (1/5) of the air supply shall be taken from the outside. In bathrooms, water closet compartments, laundry rooms and similar rooms a mechanical ventilation system connected directly to the outside, capable of providing five (5) air changes per hour, shall be provided. (d) Hallways. All public hallways, stairs and other exit-ways shall be adequately lighted at all times in accordance with the Building Code.

(Amend Ord 04-009, 1/13/04)

Ask a question about Arlington law

Corpus searches the Arlington sections it holds and shows the ones that match, with their citations. Free, no sign-in.