§ 102-385 — Installation and maintenance requirements for grease traps, grease interceptors, grit interceptors, amalgam separators, and oil/water separators
Code of Ordinances, City of Brownsville, Texas (Supp. No. 26: codified through Ordinance No. 2026-1797, enacted January 20, 2026) · Brownsville City Code § 102-385
Corpus is an independent public-information project, not the official City of Brownsville website. Stable reference: corpuslaw.us/code/af41bf1a-a9b4-4d9c-8905-b7cb6fd2ac86
Sec. 102-385. - Installation and maintenance requirements for grease traps, grease interceptors, grit interceptors, amalgam separators, and oil/water separators.
(a) Installations. (1) New facilities. Food processing or food service facilities which are newly proposed or constructed, or existing facilities which will be expanded or renovated to include a food service facility, where such facility did not previously exist, shall be required to design, install, operate and maintain a grease interceptor in accordance with the BPUB sizing formula and specifications listed in section 102-386 of this division 2, unless the facility is exempt as listed in section 102-384 of this division 2. Commercial/institutional/industrial automotive service and washing facilities which are newly proposed or constructed, or existing facilities which will be expanded or renovated to include an automotive service or washing facility, where such facility did not previously exist, shall be required to design, install, operate and maintain a grit interceptor or oil/water separator in accordance with the BPUB sizing formula and specifications listed in section 102-386 of this division 2. Dental facilities which are newly proposed or constructed, or existing facilities which will be expanded or renovated to include a dental service facility, where such facility did not previously exist, shall complete and submit a one-time compliance report and shall be required to design, install, operate and maintain an amalgam separator in accordance with the ANSI/ADA criteria as outlined in 40 C.F.R. § 441, unless the facility is exempt as listed in section 102-384(i) of this article. Additionally, a sample collection point shall be installed according to BPUB specifications for any grease trap, grease interceptor, grit interceptor, amalgam separator or oil/water separator. Grease traps, grease interceptors, grit interceptors, amalgam separators and oil/water separators shall be inspected and approved by the BPUB pretreatment department prior to the City of Brownsville issuing certificate of occupancy. (2) Existing facilities. Existing grease traps, grease interceptors, grit interceptors, amalgam separators and oil/water separators must be operated and maintained in accordance with this division 2, unless specified in writing and approved by the BPUB pretreatment manager. Additionally, a sample collection point shall be installed according to BPUB specifications for any grease trap, grease interceptor, grit interceptor or oil/water separator. (3) Existing undersized, inoperable, or defective grease traps, grease interceptors, grit interceptors, amalgam separators or oil/water separators may be required to be replaced, repaired or upgraded within a reasonable time. (4) All grease trap, grease interceptor, grit interceptor, amalgam separator and oil/water separator waste extracted, shall be properly disposed of by a registered waste hauler at a licensed/certified facility in accordance with federal, state, or local regulation. (b) Cleaning and maintenance. (1) Grease traps, grease interceptors, grit interceptors, amalgam separators and oil/water separators shall be maintained in an efficient operating condition at all times. (2) Each grease trap, grease interceptor, grit interceptor or oil/water separator pumped shall be fully evacuated unless the trap or interceptor volume is greater than the tank capacity on the vacuum truck, in which case the transporter shall arrange for additional transportation capacity so that the grease trap, grease interceptor, grit interceptor or oil/water separator is fully evacuated within a 24-hour period, in accordance with 30 Texas Administrative Code § 312.143(c), as may be periodically amended. (3) Amalgam separators shall be maintained in accordance with the manufacturer's operating manual recommendations. The manufacturer's manual must provide instructions for use, including the frequency for inspection and collecting container replacement such that the unit is replaced once it has reached the maximum filling level at which the device can perform to the specified efficiency (at least 95 percent removal efficiency). (4) The BPUB pretreatment department encourages the use of approved best management practices (BMPs) for commercial establishments to reduce or eliminate the amount of pollution indirectly discharged into the POTW. (c) Cleaning schedules. (1) Grease interceptors, grit interceptors and oil/water separators shall be completely evacuated and cleaned a minimum of every 90 calendar days or more often when necessary to ensure that sediment and floating materials do not accumulate to impair the efficiency of the grease interceptor, grit interceptor or oil/water separator; to ensure the indirect discharge is in compliance with local discharge limits; to ensure no visible oil and/or grease is observed in the indirect discharge; or when the following conditions exist: a. Twenty-five percent or more of the wetted height of the grease interceptor, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, oils or greases; b. The indirect discharge exceeds BOD, COD, TSS, FOG, pH, or other pollutant levels established by the BPUB; or c. If there is a history of non-compliance. (2) Any person who owns or operates a grease interceptor, grit interceptor or oil/water separator may submit to the BPUB pretreatment manager a request in writing for an exemption to the 90 calendar day pumping frequency of their grease interceptor, grit interceptor or oil/water separator. The BPUB pretreatment manager may grant a written extension for required cleaning frequency on a case-by-case basis when: a. The grease interceptor, grit interceptor or oil/water separator has been sized according to the BPUB sizing formula and the grease interceptor, grit interceptor or oil/water separator owner/operator has demonstrated the specific grease interceptor, grit interceptor or oil/water separator will produce an effluent, based on defensible analytical results, in consistent compliance with established local discharge limits such as BOD, TSS, FOG, or other parameters as determined by the BPUB, or b. Less than 25 percent of the wetted height of the grease interceptor, grit interceptor or oil/water separator, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, oils or greases (3) In any event, grease interceptors, grit interceptors and oil/water separators shall be fully evacuated, cleaned, and inspected at least once every 180 calendar days. (4) Grease traps shall be completely evacuated and cleaned a minimum of every 30 calendar days or more often when necessary to ensure that sediment and floating materials do not accumulate to impair the efficiency of the grease trap; to ensure the indirect discharge is in compliance with local limits; to ensure no visible oil and/or grease is observed in the indirect discharge; or when the following conditions exist: a. The indirect discharge exceeds BOD, COD, TSS, FOG, pH, or other pollutant levels established by the BPUB; or b. If there is a history of user non-compliance. (d) Manifest and record keeping requirements. (1) Each pump-out of a grease interceptor, grit interceptor, oil/water separator, or grease trap that is not cleaned as described in subsection 102-385(c) above, must be accompanied by a manifest to be used for record keeping purposes. (2) Persons who generate, collect and transport grease trap waste, grease interceptor waste, grit interceptor waste, or oil/water separator waste shall maintain a record of each individual collection, deposit to recycler, or disposal. Such records shall be in the form of a manifest. The manifest shall include: a. Name, address, telephone, and TCEQ registration number of transporter; b. Name, signature, address, and phone number of the generator of the waste and the date collected; c. Type and amount(s) of waste collected or transported; d. Name and signature(s) of responsible person(s) collecting, transporting, and depositing or disposing of the waste; e. Date and place where the waste was deposited or disposed; f. Identification (TCEQ permit or site registration number, location, and operator) of the facility where the waste was deposited or disposed; g. Name and signature of facility on-site representative acknowledging receipt of the waste and the amount of waste received for recycling or disposal; h. The volume of the grease trap waste, grease interceptor waste, grit interceptor waste or oil/water separator waste received; and i. A consecutive numerical tracking number to assist transporters, waste generators, and regulating authorities in tracking the volume of grease transported. (3) Manifests shall be divided into five parts and records shall be maintained as follows: a. One part of the manifest shall have the generator and transporter information completed and shall be given to the generator at the time of waste pickup. b. The remaining four parts of the manifest shall have all required information completely filled out and signed by the appropriate parties before distribution of the manifest. c. One part of the manifest shall be submitted to the receiving facility (recycler or disposer). d. One part of the manifest shall be submitted to the transporter, who shall retain a copy of all manifests showing the collection and disposition of waste transported. e. One copy of the manifest shall be returned by the transporter to the generator within 15 calendar days after the waste is received at the disposal or processing/recycling facility. f. One part of the manifest shall be submitted to the BPUB pretreatment department, as the local monitoring and regulatory CA. (4) Last three copies of manifests returned to the waste generator shall be kept and be readily available for review by the BPUB pretreatment personnel. (5) One-time compliance report deadlines. For existing sources, a one-time compliance report must be submitted to the control authority within 45 calendar days of the passage of this article, or 90 calendar days after a transfer of ownership. For new sources, a one-time compliance report must be submitted to the control authority no later than 90 calendar days following the introduction of wastewater into a POTW. (6) The one-time compliance report shall be retained as long as a dental discharger, subject to this subsection is in operation, or until ownership is transferred. In addition, the dental discharger or an agent or representative of the dental discharger must maintain the one-time compliance report required at paragraph (5) of this section and make it available for inspection in either physical or electronic form. (7) Persons who generate, collect and transport amalgam waste shall maintain a record of each individual collection, deposit to recycler, or disposal. Such events shall be recorded in a maintenance log and must be available for inspection by BPUB pretreatment personnel. (e) Alternative treatment. (1) A person commits a violation if he introduces, causes, permits, or suffers the introduction of a grit or garbage grinder, any surfactant, solvent, bacteria, or emulsifier into a grease trap, grease interceptor, grit interceptor or oil/water separator. Surfactants, solvents, bacteria, and emulsifiers are materials which allow the grease to pass from the grease trap, grease interceptor, grit interceptor or oil/water separator, into the sanitary sewer collection system, and include but are not limited to, enzymes, microbial agents, soap, diesel, kerosene, terpene, and other solvents. (2) It is an affirmative defense to an enforcement of subsection 102-385(f)(1) immediately above, that the use of reasonable amounts of surfactants or soaps is incidental to normal commercial/industrial kitchen hygiene operations.
(Ord. No. 2020-795-G, § 2, 2-2-2021)
Ask a question about Brownsville law
Corpus searches the Brownsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.