Sec. 102-386. - Sizing and design criteria.

(a) Grease traps. (1) Grease traps shall have a minimum capacity of 50 gallons. (2) Grease traps shall not receive liquid waste from a dishwasher appliance. (3) Grease traps shall be installed in strict accordance with the manufacturer's instructions. Grease traps shall be equipped with a cover and a mechanism for secure closure. (4) Grease traps shall be installed such that they are easily accessible for inspection, cleaning and removal of FOG and solid material. (5) A sample collection point shall be installed according to BPUB specifications. (b) Grease interceptors. (1) Grease interceptors must capture liquid waste from dishwasher appliances, pre-rinse/pre-wash sinks or sinks in dishwashing areas, compartment sinks, wok stoves, self-cleaning ventilation hoods, kitchen floor drains, floor sinks, mop sinks, food preparation sinks, hand sinks, and garbage disposers. (2) Grease interceptors shall be sized according to the BPUB sizing formula. Where the sizing formula calculates a grease interceptor size less than 500 gallons, the size shall be 500 gallons. (3) Grease interceptors shall have a minimum of two compartments with fittings designed for grease retention. (4) Grease interceptors shall have a manhole for each compartment to provide access for cleaning all areas of the interceptor. Manhole covers shall be gas tight in construction having a minimum opening dimension of 20 inches. (5) In areas where vehicle traffic exists, the grease interceptor shall be designed for adequate public traffic load bearing capacity. (6) Grease interceptors shall be installed such that they are easily accessible for inspection, cleaning and removal of grease interceptor waste. (7) A sample collection point shall be installed according to BPUB specifications. (c) Grit interceptors and oil/water separators. (1) Grit interceptors and oil/water separators shall be designed, constructed and installed in accordance with the BPUB sizing formula and specifications. (2) Grit interceptors and oil/water separators shall have a manhole for each compartment to provide access for cleaning all areas of the interceptor. Manhole covers shall be gas tight in construction having a minimum opening dimension of 20 inches. (3) In areas where vehicle traffic exists, the grit interceptor or oil/water separator shall be designed for adequate public traffic load bearing capacity. (4) Grit interceptors and oil/water separators shall be installed such that they are easily accessible for inspection, cleaning and removal of grit and oily waste. (5) A sample collection point shall be installed according to BPUB specifications. (d) Amalgam separators. (1) Amalgam separator(s) must be sized to accommodate the maximum indirect discharge rate of amalgam process wastewater. (2) Amalgam separator(s) must be inspected in accordance with the manufacturer's operating manual to ensure proper operation and maintenance of the separator(s) and to confirm that all amalgam process wastewater is flowing through the amalgam retaining portion of the amalgam separator(s). 3) The amalgam separator must meet the removal efficiency of at least 95 percent of the mass of solids from all amalgam process wastewater. The removal efficiency specified by the manufacturer must be calculated in grams recorded to three decimal places, on a dry weight. (4) Amalgam separators shall be installed such that they are easily accessible for inspection, cleaning and removal of amalgam waste.

(Ord. No. 2020-795-G, § 2, 2-2-2021)

Ask a question about Brownsville law

Corpus searches the Brownsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.