§ 5.5.15 — Provisions for Flood Hazard Reduction

Code of Ordinances, City of Brownsville, Texas (Supp. No. 26: codified through Ordinance No. 2026-1797, enacted January 20, 2026) · Brownsville City Code § 5.5.15

Corpus is an independent public-information project, not the official City of Brownsville website. Stable reference: corpuslaw.us/code/e6dd8622-e2b1-45f1-b9ab-00a722c927f3

5.5.15 - Provisions for Flood Hazard Reduction.

A. General Standards. In all areas of special flood hazards the following provisions are required for all new construction and substantial improvements: 1. All new construction or substantial improvements shall be designed (or modified) and adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; 2. All new construction or substantial improvements shall be constructed by methods and practices that minimize flood damage; 3. All new construction or substantial improvements shall be constructed with materials resistant to flood damage; 4. All new construction or substantial improvements shall be constructed with electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; 5. All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system; 6. New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the system and discharge from the systems into flood waters; and, 7. On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. B. Specific Standards. In all areas of special flood hazards where base flood elevation data has been provided as set forth in 5.5.5 Basis for Establishing the Areas of Special Flood Hazard or 5.5.15C.3, the following provisions are required: 1. Residential Construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), elevated to two (2) feet above the base flood elevation. All residential structures that are constructed outside of a designated Special Flood Hazard Area shall be elevated two (2) feet above the highest adjacent grade. A registered professional engineer, architect, or land surveyor shall submit a certification to the Floodplain Administrator that the standard of this subsection as proposed in 5.5.13A.1, is satisfied. 2. Nonresidential Construction. New construction and substantial improvements of any commercial, industrial or other nonresidential structure shall either have the lowest floor (including basement) elevated to two (2) feet above the base flood level or together with attendant utility and sanitary facilities, be designed so that below the base flood level the structure is watertight to a minimum level of two (2) feet above the base flood elevation with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this subsection. A record of such certification which includes the specific elevation (in relation to mean sea level) to which such structures are floodproofed shall be maintained by the Floodplain Administrator. 3. Enclosures. New construction and substantial improvements, with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: a. A minimum of two (2) openings on separate walls having a total net area of not less than 1 square inch for every square foot of enclosed area subject to flooding shall be provided. b. The bottom of all openings shall be no higher than one (1) foot above grade. c. Openings may be equipped with screens, louvers, valves, or other coverings or devices if they permit the automatic entry and exit of floodwaters. 4. Manufactured Home. a. Require that all manufactured homes to be placed within Zone A on a community's FHBM or FIRM shall be installed using methods and practices which minimize flood damage. For the purposes of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable State and local anchoring requirements for resisting wind forces. b. Require that manufactured homes that are placed or substantially improved within Zones A1-30, AH, and AE on the community's FIRM on the following sites: (i) Outside of a manufactured home park or subdivision, (ii) In a new manufactured home park or subdivision, (iii) In an expansion to an existing manufactured home park or subdivision, or (iv) In an existing Manufactured Home Parks and Manufactured Home Subdivisions on which a manufactured home has incurred "substantial damage" as a result of a flood, be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated to a minimum of two (2) feet above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. c. Require that Manufactured Homes be placed or substantially improved on sites in an existing Manufactured Home Parks and Manufactured Home Subdivisions with Zones A1-30, AH and AE on the community's FIRM that are not subject to the provisions of this section be elevated so that either: (i) The lowest floor of the manufactured home is at or above the base flood elevation, or (ii) The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than thirty-six (36) inches in height above grade and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. 5. Recreational Vehicles. Require that recreational vehicles placed on sites within Zones A1-30, AH, and AE on the community's FIRM either: a. Be on the site for fewer than one hundred and eighty (180) consecutive days, or b. Be fully licensed and ready for highway use, or c. Meet the permit requirements of 5.5.13A, and the elevation and anchoring requirements for "manufactured homes". A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices and has no permanently attached additions. 6. Use of Fill to Elevate Structures. If fill material is to be used to elevate any structure in Zones A, A1-30, AE, AO, AH, AR, or A99, the following will apply: a. Fill material must be compacted to at least ninety five percent (95%) of Standard Laboratory Maximum Density (Standard Proctor) according to ASTM Standard D-698; b. Fill soils must be fine grained soils of low permeability, such as those classified as CH, CL, SC, or ML according to ASTM Standard D-2487, "Classification of Soils for Engineering Purposes." See also the current building code. c. The fill material must be homogenous and isotropic; that is the soil must be all of one material, and the engineering properties must be the same in all directions. C. Standards for Subdivision Proposal. 1. All subdivision proposals including the placement of Manufactured Home Parks and Manufactured Home Subdivisions shall be consistent with 5.5.2 Purpose and 5.5.3 Methods of Reducing Flood Loss of these regulations. 2. All proposals for the development of subdivisions including the placement of manufactured home parks and subdivisions shall meet Floodplain Development Permit requirements of the following sections 5.5.6 Establishment of Development Permit, 5.5.13 Permit Procedures, and 5.5.15 Provisions for Flood Hazard Reduction. 3. Base flood elevation data shall be generated for subdivision proposals and other proposed development including the placement of manufactured home parks and subdivisions which is greater than fifty (50) lots or five (5) acres, whichever is lesser, if not otherwise provided pursuant to 5.5.5 Basis for Establishing the Areas of Special Flood Hazard or 5.5.12H of these regulations. 4. All subdivision proposals including the placement of Manufactured Home Parks and Manufactured Home Subdivisions shall have adequate drainage provided to reduce exposure to flood hazards. 5. All subdivision proposals including the placement of Manufactured Home Parks and Manufactured Home Subdivisions shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize or eliminate flood damage. D. Standards for Areas of Shallow Flooding (AO/AH Zones). Located within the areas of special flood hazard established in 5.5.5 Basis for Establishing the Areas of Special Flood Hazard, are areas designated as shallow flooding. These areas have special flood hazards associated with flood depths of one (1) to three (3) feet where a clearly defined channel does not exist, where the path of flooding is unpredictable, and where velocity flow may be evident. Such flooding is characterized by ponding or sheet flow, therefore the following provisions apply: 1. All new construction and substantial improvements of residential structures have the lowest floor (including basement) elevated to a minimum of two (2) feet above the base flood elevation or the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM (at least 2 feet if no depth number is specified). 2. All new construction and substantial improvements of nonresidential structures; a. Have the lowest floor (including basement) elevated to a minimum of two (2) feet above the base flood elevation or the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM (at least 2 feet if no depth number is specified), or b. Together with attendant utility and sanitary facilities be designed so that below the base specified flood depth in an AO Zone, or below the Base Flood Elevation in an AH Zone, level the structure is is watertight to a minimum level of two (2) feet above the base flood elevation with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads of effects of buoyancy. 3. A registered professional engineer or architect shall submit a certification to the Floodplain Administrator that the standards of this Section, as proposed in 5.5.13 Permit Procedures are satisfied. 4. Require within Zones AH or AO adequate drainage paths around structures on slopes, to guide flood waters around and away from proposed structures. E. Floodways. Floodways located within areas of special flood hazard established in 5.5.5 Basis for Establishing the Areas of Special Flood Hazard, are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of flood waters which carry debris, potential projectiles and erosion potential, the following provisions shall apply: 1. Encroachments are prohibited, including fill, new construction, substantial improvements and other development within the adopted regulatory floodway unless it has been demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment would not result in any increase in flood levels within the community during the occurrence of the base flood discharge. 2. If 5.5.15E.1 above is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of 5.5.15 Provisions for Flood Hazard Reduction. 3. Under the provisions of 44 CFR Chapter 1, Section 65.12, of the National Flood Insurance Program Regulations, a community may permit encroachments within the adopted regulatory floodway that would result in an increase in base flood elevations, provided that the community first completes all of the provisions required by Section 65.12.

Ask a question about Brownsville law

Corpus searches the Brownsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.