§ 14-133 — Tanks
Code of Ordinances of the City of College Station, Texas (Supp. No. 10 Update 2: codified through Ordinance No. 2026-4726, adopted October 22, 2026) · College Station Code of Ordinances § 14-133
Corpus is an independent public-information project, not the official City of College Station website. Stable reference: corpuslaw.us/code/610c597b-65a5-4677-8208-7904297ee6fd
Sec. 14-133. - Tanks.
(a) Location. All tanks shall be on the oil or gas operations site and set back pursuant to the standards of the Commission and the National Fire Protection Association, but in all cases shall be at least 350 feet from any existing public right-of-way, planned public right-of-way as described in the Thoroughfare Plan of the City, or property line, as measured from the tank battery containment berm. City Council may modify the tank setback distance from existing public right-of-way or planned public right-of-way as described in the Thoroughfare Plan to no less than 175 feet if the modified tank setback distance increases the separation distance from any residence or public building. (b) Specifications and height. All tanks and permanent structures shall conform to the American Petroleum Institute (A.P.I.) specifications unless other specifications are approved by the Fire Chief. The top of the tanks shall be no higher than 15 feet above the terrain surrounding the tanks, excluding required netting and support structures. (c) Vapor recovery system. Vapor recovery system equipment is required for tanks or tank batteries that have an estimated rolling annual aggregate emissions rate of 25 tons or greater of total volatile organic hydrocarbons per oil or gas operations site. (d) Vapor recovery efficiency. Vapor recovery equipment must be operated to ensure 95 percent recovery efficiency between the internal and external atmospheres of the tanks. (e) Fire suppression. Fire extinguishers and accessible foam suppression systems for all tanks and flammable fluid retaining vessels are required for all oil or gas operations. (f) Berm capacity. All tanks shall have a berm or dam of sufficient height, strength and distance from the tanks or vessels to ensure that 150 percent of the capacity of the largest tank and/or vessel and adequate freeboard to allow for precipitation can be maintained within the berm or dam. (g) Lightning arrestor. Lightning arrestors and adequate grounding equipment shall be installed for all tanks.
(Code 2011 (Repub.), § 4-13(H)(2))
Ask a question about College Station law
Corpus searches the College Station sections it holds and shows the ones that match, with their citations. Free, no sign-in.