§ 14-143 — Water wells
Code of Ordinances of the City of College Station, Texas (Supp. No. 10 Update 2: codified through Ordinance No. 2026-4726, adopted October 22, 2026) · College Station Code of Ordinances § 14-143
Corpus is an independent public-information project, not the official City of College Station website. Stable reference: corpuslaw.us/code/2a32e107-8779-41b1-86e0-e870bac2d582
Sec. 14-143. - Water wells.
(a) Location. No water wells associated with oil or gas operations shall be drilled within 1,000 feet of any other water well registered with the Brazos Valley Groundwater District or the Texas Water Development Board, located within the City limits. Any water well with steel casing shall be equipped with cathodic protection. (b) Baseline water quality. Water well samples shall be collected and analyzed prior to any drilling activity to document baseline water quality data of the well. (c) Pre-drilling water analyses required. Before an oil or gas operator commences drilling of a proposed oil or gas well within the City limits, baseline water quality testing shall be performed as set out in this section. The operator shall perform water analyses on at least one private or public water well in each aquifer with usable quality water as defined in Texas Administrative Code title 16, part 1, chapter 3, rule section 3.30(e)(7)(B)(i) that is within a radius of 1,500 feet from the proposed oil or gas well bore. If an aquifer has multiple water wells within the 1,500-foot radius, the closest water well to the oil or gas well will be the well tested. (d) Post-drilling water analyses required. The operator shall perform water analyses on the same water wells that were tested during the Pre-drilling Water Analyses within 90 days of completing the oil or gas well and one year after the completion of the well. Completing the oil or gas well in this instance is defined as perforating the well or hydraulic fracturing of the well if hydraulic stimulation is done after perforating any oil or gas formation. The water well analyses shall, at a minimum, test for the constituents listed in Subsection (g)(3) of this section. (e) Results delivered to City. The results of the water well analyses shall be delivered to the City Engineer or designee and the water well owner within 30 days of collecting the samples for testing. (f) Water well owner notification. In the case of a substantive negative change using guidelines of the Groundwater Protection Council (GWPC) in a water well quality between the pre- and post-drilling and completion testing, the oil or gas well operator shall immediately notify all property owners with water wells within 2,000 feet of the oil or gas well of the change in water quality. (g) Water analyses requirements. Water analyses and testing shall conform to the following testing requirements: (1) Collection of samples. Water samples must be collected by personnel employed by an independent laboratory certified under the National Environmental Laboratory Accreditation Program for Drinking Water. (2) Laboratory analyses. The water analyses shall be performed by a laboratory certified under the National Environmental Laboratory Accreditation Program for Drinking Water. (3) Testing parameters. Parameters to be tested for include, but are not limited to, barium, boron, chlorides, sodium, total dissolved solids (TDS), strontium, ethane, ethylene, methane, semi-volatiles, total petroleum hydrocarbons (TPH), and volatile organic compounds (VOCs). (h) Cross connection control. Any connection to a freshwater source, including, but not limited to, the City public drinking water system, private wells, other surface and/or groundwater sources, shall comply with all cross-connection control requirements.
(Code 2011 (Repub.), § 4-13(H)(12))
Ask a question about College Station law
Corpus searches the College Station sections it holds and shows the ones that match, with their citations. Free, no sign-in.