§ 17-158 — Ventilation
Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton City Code § 17-158
Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/cc265f2d-8385-4416-8aae-95adbbbac4b1
Sec. 17-158. - Ventilation.
(a) Habitable spaces. Every habitable space shall have at least one (1) openable window. The total openable area of the window in every room shall be equal to at least forty-five (45) percent of the minimum glazed area required in section 17-157(a). Where rooms and spaces without openings to the outdoors are ventilated through an adjoining room, the unobstructed opening to the adjoining room shall be at least eight (8) percent on the floor area of the interior room or space, but not less than twenty-five (25) square feet. The ventilation openings to the outdoors shall be based on a total floor area being ventilated. (b) Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by section 17-158(a), except that a window shall not be required if equipped with a mechanical ventilation system. Air exhausted by a mechanical ventilation system from a bathroom or toilet room shall discharge to the outdoors, and shall not be recirculated. (c) Cooking facilities. All rooms and other enclosed spaces shall be ventilated in a manner sufficient to keep them free of excessive heat, steam, condensation, vapors, offensive odors, smoke, and fumes. Further, habitable spaces may not be used as cooking facilities, unless: (1) Approved through a certificate of occupancy; (2) Approved in writing by the building official; or (3) Only allowable devices are being used. Coffee pots and microwaves are not considered cooking appliances. (d) Process ventilation. Where injurious, toxic, irritating or noxious fumes, gases, dusts or mists are generated, a local exhaust ventilation system shall be provided to remove the contaminating agent at the source. Air shall be exhausted to the exterior and not be recirculated to any space. (e) Clothes dryer exhaust. Dryer exhaust systems shall be independent of all other ventilation systems, and shall convey the moisture to the outdoors, unless ductless, condensing clothes dryers are installed. Intake and exhaust air ducts shall be maintained in such a manner as to prevent the entrance of dust, dirt, and any other contaminating materials.
(Ord. No. 2010-132, § 1, 5-11-10; Ord. No. 24-1647, § 2(Exh. A), 10-15-24)
Ask a question about Denton law
Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.