Sec. 17-166. - Mechanical facilities.

Heating and air conditioning facilities shall be maintained in structures as required by this article. (a) Heating. Every dwelling unit and guest room shall be provided with heating facilities capable of maintaining a room temperature of 68°F at a point three (3) feet above the floor in all habitable rooms. Such facilities shall be maintained in a safe condition and in accordance with the adopted building code, the adopted mechanical code and all other applicable laws. Unvented fuelburning heaters shall not be permitted as the sole source of heating for any room or space. All heating devices or appliances shall be of an approved type, and at no time, shall cooking appliances be used to provide space heating to meet the requirements of this article. (b) Air conditioning. An owner shall provide refrigerated air equipment in rental dwelling units. When refrigerated air equipment is provided in rental units, it shall be maintained in operable condition and must be capable of maintaining a maximum inside temperature that is 20° lower than the outside temperature or 81°F, whichever is warmer, in each room of a structure intended for human occupancy from May 1 through October 1. If provided refrigerated air equipment becomes in need of repair, owner shall repair said equipment within a reasonable time. (c) Employee work spaces. Indoor employee work spaces shall be supplied with sufficient heat to maintain an ambient temperature of 65°F measured at a point three (3) feet above the floor near the center of the room or space. Spaces designed to be maintained at a temperature below 65°F, including but not limited to coolers, freezers, computer cold rooms and other similar areas, shall be exempt from this requirement. Additionally, areas whose primary function is not for human comfort and in which employees engage in vigorous physical activity during the normal course of their duties may also be exempted from this requirement.

(Ord. No. 2010-132, § 1, 5-11-10; Ord. No. 24-1129, § 2, 6-18-24)

Ask a question about Denton law

Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.