Sec. 26-320. - Backflow prevention assembly requirements.
(a) A member of the regulatory authority shall determine the type and location of the backflow prevention assembly to be installed on any connection to the PWS. (b) Use of an approved backflow prevention assembly solely at the service connection does not satisfy the backflow protection requirements found in the PC or this article. (c) An approved backflow prevention assembly shall be required at the service connection for the purpose of containment in any of the following circumstances: (1) When the nature and extent of any activity at a premises, the materials used in connection with any activity at a premises, or the materials stored at the premises may introduce contaminants into the PWS; (2) When internal cross-connections are present and not correctable; (3) When intricate plumbing arrangements are present that make it impractical to ascertain whether cross-connections exist; (4) When a premises has a repeated history of cross-connections being established or reestablished; (5) When entry to a premises is unduly restricted so that inspections for cross-connections cannot be made with sufficient frequency to ensure that cross-connections do not exist; (6) When materials are being used such that if backflow or backsiphonage occurs, a health hazard could result; (7) When an appropriate cross-connection survey report form is not on file with the director; (8) When a fire sprinkler system is connected to the PWS; (9) When there is non-residential new construction; (10) On all new construction involving premises owned by any state, federal, or foreign government or agency; (11) When the end use of a non-residential premises cannot be determined or could change; (12) When a point-of-use isolation assembly has not been tested or repaired as required by this article; (13) When any member of the regulatory authority determines that additions or alterations have been made to the private water system without the proper permits required by the Plumbing Code; (14) When any premises have a booster pump, elevated storage tank, or total height exceeding eighty (80) feet; (15) When a premises is connected to the reclaimed water system; (16) When a premises is supplied water by the city and has an auxiliary water supply; (17) On all new construction when a premises is supplied water by the city and is located outside the city's corporate boundary; or (18) When any circumstance exists that, in the opinion of the director, may result in contamination. (d) An approved backflow prevention assembly shall be required for the purpose of point-of-use isolation in any of the following circumstances: (1) When a premises has any cross-connection(s); (2) When a contaminant or pollutant could make its way into the PWS; (3) When there is a used water return system; or (4) When installation of an approved backflow prevention assembly is deemed necessary by any member of the regulatory authority to protect the PWS from actual or potential contamination. (e) An existing backflow assembly must be replaced with an approved backflow prevention assembly when: (1) A health hazard exists; or (2) The director determines that replacement is necessary to protect the PWS from contamination or pollution. (f) When a premises is required to have backflow prevention assemblies, but water cannot be turned off during the testing of such assemblies, the premises shall be equipped with dual backflow prevention assemblies of the same type so that testing, repair, and maintenance can be performed. (g) A user commits an offense if the user fails to install and maintain backflow prevention assemblies on a premises as required by this article. (h) A user commits an offense if backflow from the premises enters the PWS. (i) Backflow prevention assemblies may be exempted from portions of section 26-332 of this article if such backflow assemblies: (1) Do not comply with the requirements of this article; (2) Were installed prior to the effective date of this article; (3) Complied with the Code of the City of Denton, Texas and state and federal law for the purposes described herein at the time of their installation; (4) Have been properly maintained; (5) Will satisfactorily protect the public water system, as determined by the director; and (6) Meet the current minimum requirements of state law and the commission, as amended. (j) An existing backflow prevention assembly must be replaced with a new approved backflow prevention assembly meeting the requirements of this article when the backflow prevention assembly: (1) Is moved from its last documented location; (2) Requires more than minimum maintenance; or (3) Requires maintenance that, in the opinion of the director, constitutes a health hazard.
(Ord. No. 25-1726, § 3(Exh. A), 3-24-26)
Ask a question about Denton law
Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.