Sec. 26-331. - Testing of assemblies.
(a) The director may, at their discretion, require inspection, testing, or both of any backflow prevention assembly when any of the following circumstances apply: (1) Immediately after installation of a backflow prevention assembly; (2) Whenever a backflow prevention assembly is moved; (3) On all new construction involving non-residential premises: a. A minimum of once (1) per year for all backflow prevention assemblies listed on the University of Southern California's Foundation for Cross-Connection Control and Hydraulic Research (USC-FCCCHR) List of Approved Assemblies; or b. A minimum of twice (2) per year for all backflow prevention assemblies that are not listed on the University of Southern California's Foundation for Cross-Connection Control and Hydraulic Research (USC-FCCCHR) List of Approved Assemblies; (4) Prior to re-occupancy when any premises have been vacated and unoccupied for one (1) year; (5) Immediately after repair of a backflow prevention assembly; (6) Immediately after replacement of a backflow prevention assembly; (7) When the director determines backflow prevention assembly testing is necessary to protect the PWS from contamination or pollution; or (8) After any deficiency or violation of this article including, but not limited to, the following: a. Falsification of a test report form; b. Incorrect, blank, or incomplete information fields on a test report form; or c. When a person who does not meet the requirements of sec. 26-334 tests a backflow assembly. (b) If a test under section 26-331(a) is required, the director may supervise the test to confirm compliance with this article. Failure to allow supervision under this section will result in revocation of the tester's registration. (c) Users shall notify the director of a failed backflow prevention assembly test within three (3) days of receiving the results. The notification must provide dates for retesting and any repairs. (d) Upon receipt of a notification under section 26-331(c), the director shall determine whether the backflow assembly must be replaced and whether water service will be discontinued until an approved backflow prevention assembly is installed. Users must replace the backflow assembly if the director determines replacement is necessary to protect the PWS from contamination or pollution. Replacement of the backflow assembly must be completed by the deadline provided by the director. (e) All backflow prevention assembly testing not involving a fire protection system must be performed by a tester, as defined in this article. (f) All backflow prevention assembly testing involving a fire protection system must be performed by a fire line tester, as defined in this article. (g) Users must have all backflow prevention assemblies tested in accordance with this article. (h) Premises with installed backflow prevention assemblies that are not registered with the city shall come into compliance with this article within sixty (60) days of notification from the director. (i) Notwithstanding the sixty (60) days provided in section 26-331(h), if the director finds that a health hazard exists, the director shall determine the appropriate time for compliance with this article. (j) All backflow prevention assembly test results shall be submitted online through the city's approved website or as directed by the director. (k) A person commits an offense if the person owns or controls any premises and fails to install any backflow prevention assembly required by this article. (l) A person commits an offense if the person owns or controls any premises and fails to test any required backflow prevention assembly in accordance with this article. (m) The city shall not be liable for damage to a backflow prevention assembly that occurs during testing.
(Ord. No. 25-1726, § 3(Exh. A), 3-24-26)
Ask a question about Denton law
Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.