For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7.10.4 — Multifamily Site and Building Design

Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton Development Code subch. 7, § 7.10.4

Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/11c47eed-cb83-45f7-b25b-f47700a22dbb

7.10.4 - Multifamily Site and Building Design.

A. Applicability. This subsection applies to any multifamily development, except those that are part of a mixed-use building. B. Site Design and Orientation. 1. Primary Building Access. Primary building access shall be oriented towards the adjacent street, and building access shall be provided from the street and/or sidewalk. 2. Multi-Building Developments. For developments with three or more buildings, the buildings shall be arranged using one or more of the following techniques: a. Organize units around a central courtyard that maintains a consistent side yard setback between units along the street frontage; b. Locate the buildings on the corner of an adjacent street intersection or entry point to the development to frame the corner; c. Provide common gathering spaces between buildings; and/or d. Other site improvements as approved by the Director that do not conflict with this DDC. Figure 7.10-C: Multi-Building Developments [image omitted; see the official code] 3. Location of Trash Storage and Mechanical Equipment. Trash storage areas, mechanical equipment, and similar areas shall not be visible from public view, and shall not be located between the building and the street. C. Open Space Requirements. Any development consisting of 10 or more dwelling units shall set aside a minimum of eight percent of the land area as open space for the use and enjoyment of the development's occupants and users. Open space serves numerous purposes, including preservation and protection of natural areas and features, providing opportunities for passive and active recreation, enhancing management of stormwater runoff to protect water quality and reduce flooding, and mitigating the heat island effect of developed areas. This requirement does not apply to multifamily developments in the MD zoning district. 1. Design of Open Space. Such open space shall meet the following design standards: a. To the maximum extent practicable, required open space shall be located and configured to include, protect, or enhance natural resource or hazard areas (including but not limited to lakes, ponds, streams, flood hazard areas, and drainage ways); b. Areas covered by shrubs, bark mulch and other ground covers that do not provide a suitable surface for human use may not be counted toward this requirement; c. Required open space areas shall be compact and contiguous unless a different configuration is needed to continue an existing trail or accommodate preservation of natural features; d. Required open space shall be located to be readily accessible and useable by occupants and users of the development. Where possible, a portion of the open space should provide focal points for the development through prominent placement or easy visual access from streets; and e. If the development site is adjacent to existing or planned parks, greenways, or other public open space, required open space shall, to the maximum extent practicable, be located to adjoin, extend, and enlarge the park, greenway, or other public open space. 2. Ownership, Management, and Maintenance of Open Space. a. Required open space area shall be managed and maintained as permanent open space through one or more of the following options: i. Open space may be held in common ownership by the owner(s) of the development, who will be responsible for managing and maintaining the land for its intended open space purposes. ii. Open space areas may be conveyed to a property owners' or homeowners' association that holds the land in common ownership and will be responsible for managing and maintaining the land for its intended open space purposes. iii. Open space areas may be conveyed to a third-party beneficiary such as an environmental or civic organization that is organized for, capable of, and willing to accept responsibility for managing and maintaining the land for its intended open space purposes. iv. Open space areas may be dedicated to the public and conveyed to the city or other public agency that is organized for, capable of, and willing to accept responsibility for managing and maintaining the land for its intended open space purposes. b. Easements may be established on those parts of individually-owned lots including open space areas that require the areas to be managed consistent with their intended open space purposes and prohibit any inconsistent future development. Any options involving private ownership of required open space area shall include association by-laws, deed restrictions, covenants, or other legal instruments that ensure continued use of the land for its intended open space purposes and provide for the continued and effective management, operation, and maintenance of the land and facilities. Such instruments shall be approved by the city as sufficient to comply with this standard before or in conjunction with approval of any subdivision approval for the development, or any construction plan approval for the development (if no subdivision approval is required). c. Responsibility for managing and maintaining open space areas lies with the owner of the land comprising the areas. Failure to maintain open space areas in accordance with the approved development shall be a violation of this DDC. Identification of who bears responsibility for managing and maintaining open space areas shall be shown on any recorded subdivision plat for the development or any approved construction plan for the development (if no subdivision approval is required). D. Architectural Requirements. 1. Limitation on Same Building Design. For projects with 30 dwelling units or greater, or more than three buildings, the same exterior design may not be used for greater than 30 units and/or more than three buildings in a project. A variety of compatible exterior materials' use and type, building styles, massing, composition, and prominent architectural features, such as door and window openings, porches, rooflines, shall be used. 2. Entries. a. Primary building entries shall be denoted through the use of distinctive architectural elements and materials, such as ornamental glazing or paving, over doors, porches, trellises, or planter boxes or as otherwise identified in this section. b. In the mixed-use zoning districts, residential units abutting a public street shall be designed with entries and windows facing the street. In all cases, buildings shall be designed to distinguish the private realm from the public realm through such features as, but not limited to, elevation change or fencing. E. Building Mass and Form. 1. General. a. Buildings shall be designed to prevent the appearance of straight, unbroken lines in the horizontal and vertical surface. Buildings shall have no more than 50 continuous feet without a horizontal and vertical break of at least three feet. Such breaks may include recesses, projections, windows, roofs, alcoves, porticoes, awnings, and other architectural features to provide visual interest and relief. b. Façades shall be broken up to give the appearance of a collection of smaller structures. Elements including but not limited to balconies, recessions, and projections may be used to articulate individual units or collections of units. c. Buildings visible from the public right-of-way or private street system shall include changes in relief such as columns, cornices, bases, fenestration, and fluted masonry, for at least 15 percent of the exterior wall area. d. Stairwells shall not be a prominent feature of any building façade, and shall be shielded from view from public and private streets to the maximum extent practicable. e. Any building constructed with a flat roof shall contain a distinctive finish consisting of a cornice, banding, or other architectural termination. 2. Additional Requirements in Mixed-Use Zoning Districts. In the mixed-use zoning districts, the following additional requirements apply: a. Buildings shall be designed to reduce apparent mass by including a clearly identifiable base, body, and top, with horizontal elements separating these components. The component described as the body must constitute a minimum of 50 percent of the total building height; b. The first floor of multifamily buildings shall be a minimum of 12 feet in height; and c. Stoops and higher finish-floor elevations are encouraged on the street-facing elevation for multi-family buildings. Buildings that provide stoops and/or finish-floor elevations that rise at least two feet above the sidewalk may measure building height from the beginning of the first floor, instead of from grade. F. Accessory Structure/Garage. 1. Garages, carports, storage units, and other accessory structures (but not including leasing offices, club houses, or recreation centers) shall not be located along the portion of the building that fronts the public or private street. 2. Garages shall not occupy more than 40 percent of the total building frontage. This measurement does not apply to garages facing an alley or courtyard entrance. 3. Garages, carports, storage units, and other accessory structures visible from the public right-of-way, private street system, and/or adjacent residential properties shall include at least three of the following: a. Façade modulation of at least six inches for every 30 feet of wall length; b. Multiple building materials (e.g., brick, fieldstone, limestone, marble, granite, textured block, architectural pre-cast concrete, cementitious siding, wood clapboard siding, wood beaded siding, or stucco); c. Multiple surface textures (e.g. rough, striated, imprinted, etc.) or patterns; or d. Separation in roof pitch, variation in direction of roof pitches, inclusion or dormers, or other variation on roof design. G. Building Transparency/Windows. 1. Within the front façade (front adjoining a public or private right-of-way where the entrance/address is located), windows and doors (excluding garage doors) shall comprise at least 25 percent of the wall area. 2. For all other façades that face a public or private street or right-of-way (excluding alleys), windows and doors (excluding garage doors) shall comprise 15 percent of the wall area. 3. Windows shall be provided with trim or shall be recessed. Windows shall not be flush with exterior wall treatment. Windows shall be provided with an architectural surround at the jamb. 4. Use of false door or window openings shall be defined by frames, sills, and lintels. H. Building Materials. 1. An amount equal to 40 percent of the total net exterior wall area of each building elevation, excluding gables, windows, doors and related trim, shall be masonry. 2. Other building materials may be approved by the Director provided they meet the intent of this section.

Ask a question about Denton law

Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.