For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7.10.5 — Nonresidential and Mixed-Use Buildings

Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton Development Code subch. 7, § 7.10.5

Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/7346fc1f-14a5-4e2a-b0f4-4cd5782297f9

7.10.5 - Nonresidential and Mixed-Use Buildings.

A. Applicability. 1. This subsection applies to any nonresidential or mixed-use development. 2. These standards do not apply to industrial uses in the LI or HI zoning districts where the building or structure is located: a. Farther than 250 feet from the ultimate right-of-way of an arterial, collector, or interstate roadway; or b. Behind another building or structure that screens the building or structure from the adjacent arterial or interstate roadway. 3. Alternatives to these standards may be approved by the Director if: a. The building is not accessed by pedestrians, such as warehouses and industrial buildings without attached offices, automotive service uses such as gasoline sales and automobile sales; or b. The development is on an infill site; or c. The design results in a higher-quality product that exceeds the minimum standards in this subchapter. B. Site Design and Orientation. 1. The primary entrance of a building shall have a clearly defined, highly visible customer entrance with distinguishing features such as a canopy, portico, or other prominent element of the architectural design. 2. Buildings shall have their primary orientation toward the street rather than the parking area. 3. Buildings that are within 30 feet of the street shall have an entrance for pedestrians from the street to the building interior. 4. Trash storage areas, mechanical equipment, loading areas, and similar areas shall not be visible from public view, and shall not be located between the building and the street. C. Multi-Building Developments. For developments with three or more buildings, the buildings shall be arranged using one or more of the following techniques: 1. Organize units around a central courtyard that maintains a consistent side yard setback between units along the street frontage; 2. Locate the buildings on the corner of an adjacent street intersection or entry point to the development to frame the corner; 3. Provide outdoor dining and/or common gathering spaces between buildings; and/or 4. Other site improvements as approved by the Director that do not conflict with this DDC. Figure 7.10-D: Multi-Building Development [image omitted; see the official code] D. Building Mass and Form. Buildings shall have no more than 50 continuous feet without a horizontal and vertical break of at least three feet. Such breaks may include recesses, projections, windows, roofs, alcoves, porticoes, awnings, and other architectural features to provide visual interest and relief. E. Building Transparency/Windows. 1. Use of glass for displays and to allow visual access to interior space is permitted. Buildings may not incorporate glass for more than 70 percent of the building skin. 2. Windows shall be provided with trim. Windows shall not be flush with exterior wall treatment. Windows shall be provided with an architectural surround at the jamb. F. Building Materials. 1. Fronts and street sides of buildings visible from the public right-of-way shall be non-reflective and shall be of wood, masonry, stucco, EIFS (Exterior Insulation Finishing System), or cementitious siding. 2. Masonry shall comprise a minimum of 50 percent of the exterior finishes of the total building elevation. 3. A maximum of 10 percent of architecturally finished metal can be used as an accent material or for embellishments on buildings classified as commercial uses, except that in the LI and HI districts along an arterial, architecturally finished metal can be used for up to 50 percent of the building façade. 4. Other building materials may be approved by the Director provided they meet the intent of this section. G. Additional Standards in the MN and MD Districts. 1. Applicability. a. These standards apply to nonresidential and mixed-use development in the MN and MD districts. b. These standards are in addition to those required for nonresidential and mixed-use development in Subsection 7.10.5. c. Where these standards conflict with the standards in Subsection 7.10.5, these standards shall apply. 2. Site Design and Orientation a. At least 60 percent of the street frontage shall have buildings within 10 feet of the front property line. b. A building shall be setback not more than 15 feet from the public right-of-way unless the area is used for pedestrian activities such as plazas or outside eating areas. Figure 7.10-E: Site Design and Orientation [image omitted; see the official code] c. Buildings that are open to the public and are within 30 feet of the street shall have an entrance for pedestrians from the street to the building interior. This entrance shall be designed to be attractive and functional, be a distinctive and prominent element of the architectural design, and shall be open to the public during all business hours. d. Buildings shall incorporate lighting and changes in mass, surface, or finish emphasizing entrances. 3. Building Mass and Form a. The top floor of any building rising over four stories shall incorporate a distinctive finish, consisting of a cornice or other architectural termination. b. Buildings shall be designed to reduce apparent mass by including a clearly identifiable base, body, and top, with horizontal elements separating these components. The component described as the body must constitute a minimum of 50 percent of the total building height. 4. Building Transparency/Windows. a. Any ground floor wall facing a main street, plaza, or other public open space shall contain at least 50 percent of the wall area facing the street in display areas, windows, or doorways. b. At least 20 percent of each upper floor facing a main street, plaza, or other public open space shall contain windows or doorways. c. Windows shall allow views into working areas or lobbies, pedestrian entrances, or display areas. d. Walls facing side streets shall contain at least 25 percent of the wall space in windows, display areas, or doors, provided: i. Blank walls within 30 feet of the side street are prohibited. ii. Up to 40 percent of the length of the building can be exempted from this standard if oriented toward loading or service area. 5. Building Materials. a. A maximum of 10 percent of architecturally finished metal can be used as an accent material or for embellishments on buildings classified as nonresidential uses. b. Buildings shall include changes in relief such as columns, cornices, bases, fenestration, and fluted masonry, for at least 15 percent of the exterior wall area. 6. Streetscape. Hardscape (paving material) shall be used to designate pedestrian-oriented areas. Sample materials could be pavers, scored and colored concrete, grass-crete, or combinations of the above.

Ask a question about Denton law

Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.