Sec. 98.16 - Sidewalk classifications; width, thickness, slope and conformance to grades and line.

Sidewalks shall be classed as number one and number two. Number one shall extend from the curb to the property line; number two shall be four feet in width. Sidewalks shall be five inches thick as follows: a one-inch layer of sand, gravel or cinders, a four-inch layer of concrete and layer of dry mix cement and sand. The walk shall have a maximum slope of one-fourth inch to one foot toward the street. The parking or space between the walk and the curb shall have a maximum slope of one-half inch to one foot toward the street. The sidewalk and curb shall conform to the line and grades as given by the City Engineer.

(`82 Code, § 19-21) (Ord. 106, passed 2-21-50)