§ 2.05.05 — TO – Tollway Overlay Design District
Code of Ordinances, City of Frisco, Texas (Frisco City Code, Home Rule Charter and Code Appendix current through Ordinance 2026-10-64 adopted October 20, 2026 (eCode360 publication FR6313, scraped 2026-11-18)) · Frisco City Code § 2.05.05
Corpus is an independent public-information project, not the official City of Frisco website. Stable reference: corpuslaw.us/code/e95c587a-2847-4ba3-964c-4c6dc8ecaa6e
§ 2.05.05: TO – Tollway Overlay Design District.
(A) General purpose and description. The Dallas North Tollway is a primary thoroughfare within the City. The TO – Tollway Overlay Design District establishes design and development standards for properties within the Tollway corridor regarding land uses, building orientation, site amenities, access, site and building architectural design, building materials, landscaping, lighting, and signage. The TO – Tollway Overlay Design District is intended to substantially advance a legitimate governmental interest that includes enhancing the quality of life in Frisco, to regulate the character of growth along the Tollway corridor, and to create a unique Tollway corridor. (B) Boundary and applicability. (1) Geographic boundary. The TO – Tollway Overlay Design District is defined as the land included within seven hundred fifty (750) feet of the Right-of-Way Line on either side of the Tollway. See Figure 2.05.05.1 for a comprehensive view of the District. (2) Certain standards apply beyond geographic boundary. For properties extending beyond the seven hundred fifty (750) foot boundary, the overlay architectural elements, building materials, and landscaping requirements shall be incorporated unless otherwise approved by the Director. (3) Land uses regulations apply only within geographic boundary. Land use requirements shall not apply to that portion of the properties beyond the seven hundred fifty (750) foot boundary. (C) Tollway Overlay Sub-districts established. The TO – Tollway Overlay Design District is divided into four sub-districts. The sub-districts and their boundaries are the following. (1) "U.S. 380 Gateway." The boundary of the U.S. 380 Gateway sub-district extends from U.S. Highway 380 to C.R. 26 (future Virginia Parkway). (2) "Typical." The boundaries of the Typical Corridor sub-districts extend from C.R. 26 to Cottonwood Creek and from Stewart Creek to Gaylord Parkway. (3) "Historic." The boundary of the Historic Gateway sub-district extends from Cottonwood Creek to Stewart Creek. (4) "S.H. 121 Gateway." The boundary for the S.H. 121 Gateway sub-district extends from Gaylord Parkway to S.H. 121. (D) Tollway Overlay Design District boundary map. (1) See boundary map: [image] Figure 2.05.05.1: Tollway Overlay Design District Map (E) Tollway Overlay Sub-district compliance. (1) Compliance sections. Each sub-district shall comply with the general requirements listed in subsection (F) General Requirements of the Tollway Overlay Design District and the sub-district requirements listed in subsection (G) Tollway Overlay Sub-District Requirements. (2) Conflicts between zoning districts. Where TO – Tollway Overlay Design District requirements conflict with base zoning requirements, excluding requirements contained within a PD – Planned Development District, the TO – Tollway Overlay Design District shall apply. Otherwise, the TO – Tollway Overlay Design District shall not affect the base zoning of a property. (F) General requirements of the Tollway Overlay Design District. (1) Permitted uses. a. The base zoning district of a property determines the permitted land uses in the TO – Tollway Overlay Design District. b. Permitted land uses are outlined in Subsection 3.02 Use Chart. (2) Tollway Overlay exterior appearance of buildings/structures. a. A Facade Plan shall be submitted for the following requirements according to Subsection 6.16 Facade Plan Review. b. Windows shall conform to the following criteria. 1. Pink or gold glass is not permitted. c. Primary exterior materials shall conform to the requirements found in 4.07.09 Exterior Construction of Main Buildings. In addition to these requirements, the following criteria shall apply. 1. The use of Exterior Insulated Finishing System (EIFS) is not permitted below nine (9) feet above finished grade. The use of EIFS above nine (9) feet is limited to high impact EIFS. 2. In the Historic Sub-District, one hundred (100) percent of the first floor facade shall consist of clay-fired brick. 3. Secondary materials used on the facade of a building are those that comprise less than ten (10) percent of an elevation area. Permitted secondary materials are all primary materials, aluminum or other metal, or other materials as approved by the Director. 4. Structured parking garages must be finished on all four sides in the same materials as the main building, or another material as approved by the Director. d. All retail/commercial buildings shall comply with Subsection 4.09 Nonresidential Design Standards. e. Corporate identities that conflict with the building design criteria shall be reviewed on a case by case basis and approved by the Director. (3) Tollway Overlay enhanced light standards. a. All vehicular-scale and pedestrian-scale light standards within the Tollway Overlay Design District requiring a pole shall use a decorative pole as approved by the City. The Tollway Overlay Design District is designated as a "design district" pursuant to Section 284.002(5) and Section 284.105 of the Texas Local Government Code, as it exists or may be amended. (G) Tollway Overlay Sub-district requirements. (1) U.S. 380 Gateway. a. Setbacks and landscape buffer. 1. The minimum front yard is fifty (50) feet. 2. Street frontage shall include a landscape buffer according to Section 4.02.05 Street Frontage Landscape Areas - Street Type S4 - Single Row Street Frontage. 3. The minimum front yard for buildings of six (6) or more stories may be reduced to twenty-five (25) feet with a twenty-five (25) foot landscape buffer. (2) S.H. 121 Gateway. a. Setbacks and landscape buffer. 1. The minimum front yard is fifty (50) feet. 2. Street frontage shall include a landscape buffer according to Section 4.02.05 Street Frontage Landscape Areas - Street Type S4 - Single Row Street Frontage. 3. The minimum front yard for buildings of six (6) or more stories may be reduced to twenty-five (25) feet with a twenty-five (25) foot landscape buffer. (3) Historic Sub-district. a. Setbacks. Setbacks in the Historic sub-district shall meet the requirements of the OTC – Original Town Commercial District (see 2.04.04(C) Regulations. (4) Typical Sub-district. a. Setbacks and landscape buffer. 1. The minimum front yard is fifty (50) feet. 2. Street frontage shall include a landscape buffer according to Section 4.02.05 Street Frontage Landscape Areas - Street Type S4 - Single Row Street Frontage.
( Ordinance 17-08-56 adopted 8/15/17 ; Ordinance 2021-07-47 adopted 7/6/21 ; Ordinance 2024-05-21 adopted 5/7/2024 )
Ask a question about Frisco law
Corpus searches the Frisco sections it holds and shows the ones that match, with their citations. Free, no sign-in.