§ 2.05.06 — US 380 Overlay Design District
Code of Ordinances, City of Frisco, Texas (Frisco City Code, Home Rule Charter and Code Appendix current through Ordinance 2026-10-64 adopted October 20, 2026 (eCode360 publication FR6313, scraped 2026-11-18)) · Frisco City Code § 2.05.06
Corpus is an independent public-information project, not the official City of Frisco website. Stable reference: corpuslaw.us/code/6986f937-bfdd-4ddd-b5ee-51aae3b5e606
§ 2.05.06: US 380 Overlay Design District.
(A) General purpose and description. The US 380 Overlay Design District ("District") establishes development standards for properties within the City's northern corridor regarding land uses, site design, landscaping, architectural design, and building materials. The District is intended to create vibrant, high-quality development that capitalizes on the corridor's strategic location, natural amenities, and regional employment opportunities to create sustained investment within the City that enhances the long-term health, safety, and quality of life for residents, employees, and visitors. (B) Boundary. The District is bounded by US 380 to the north, Coit Road to the east, PGA Parkway and Parvin Branch to the south, and various land use boundaries to the south and west. The property between Legacy Drive and Championship Drive is excluded from the District. Reference Figure 2.05.06.1 US 380 Overlay Design District Boundary. The District excludes all single-family residential subdivisions platted prior to the establishment of the District. It is the intent of the District that gateway provisions apply to adjacent parcels or tracts that front on thoroughfare right-of-way located within the District boundaries for a symmetrical look. Where the boundaries of the US 380 Overlay Design District overlap with the TO – Tollway Overlay Design District or the PRO – Preston Road Overlay Design District, the provisions of each district shall apply. In the case of a conflict, the US 380 Overlay Design District shall apply. (C) US 380 Overlay Sub-districts. The District is divided into three sub-districts. Reference Figure 2.05.06.2 US 380 Overlay Sub-district Boundaries. The sub-districts are: (1) Business. (2) Mixed-Use Residential. (3) Urban Center. Where the District requirements conflict with base zoning requirements, the District shall apply, unless the property is in a Planned Development, in which case the Planned Development standards shall apply. The overlay district does not change the base zoning but does amend the development standards and uses. [image] [image] (D) General requirements of the US 380 Overlay District. (1) US 380 Overlay permitted and special uses. a. Uses permitted in the District are outlined in Subsection 3.01 Use of Land and Buildings. b. Conditional development standards. 1. Drive-throughs (i.e., banks, restaurants, dry cleaners, etc.). (i) Drive-through facilities, including drive-through lanes, order boards, and pick-up windows, shall not be located at the intersection of two major thoroughfares, as defined in Frisco's Engineering Standards Section 2.02.A.1 (e.g., US 380, Dallas Parkway, FM 423, Preston Road, Legacy Drive, PGA Parkway, etc.); and (ii) Where buildings are not required to sit on the build-to line as noted in Table 2.05.06.1, a drive aisle may be allowed to circulate between a drive-through use and the major thoroughfare (provided it does not violate Subsection D(1)b.1. However, no two adjacent drive-through uses shall both have a drive-aisle circulate next to the major thoroughfare. 2. Gas pumps. (i) Where located at intersecting streets, gas pumps and canopy structures shall be shielded from view from at least one street by the principal building in which the facilities serve, as depicted in Figure 2.05.06.3 Gas Pumps/Canopy Placement. [image] Figure 2.05.06.3, Gas Pumps/Canopy Placement 3. Big box retail development. (i) Big box retail building facades shall not abut the build-to line of a major thoroughfare. Facades that face a major thoroughfare shall adhere to one of the following two provisions: A. Big box retail building facades shall adhere to the Building Design requirements noted in Subsection 2.05.06(D)(4) Exterior Appearance of Buildings and Structures; or B. Big box retail building facades shall be concealed behind other buildings on the tract which can adhere to the Building Design requirements noted in Subsection 2.05.06(D)(4) Exterior Appearance of Buildings and Structures. (ii) Where big box retail buildings are part of a planned shopping center or located within a mixed-use development, associated single or multi-tenant retail buildings shall be arranged to frame the development tract and internal parking areas. Such buildings shall be designed with dual frontage that provides direct pedestrian access from the adjacent street, excluding US 380, and from internal parking areas where possible. (2) US 380 Overlay site development. a. Frontage. Applicable to development between Championship Drive and LaCima Boulevard: 1. Buildings at the intersection of US 380 and a major thoroughfare, a minor thoroughfare, or a commercial collector shall be constructed to the build-to-line and shall adhere to the minimum building corner frontage requirement noted in Table 2.05.06.1. Buildings beyond what is required to meet the minimum building corner frontage requirement shall meet one of the conditions below. (i) Buildings shall back to US 380, a major thoroughfare, a minor thoroughfare, or a commercial collector and shall be constructed to the build-to line noted in Table 2.05.06.1. Surface parking shall be situated toward the interior of the development and have limited direct frontage on public streets. This condition shall be met unless a waiver is approved by the Director of Development Services. An appeal to a decision on a waiver by the Director of Development Services may be considered by the Planning & Zoning Commission. If further appeal is made, the City Council shall act on such an appeal. (ii) Buildings shall back to US 380, a major thoroughfare, a minor thoroughfare, or a commercial collector with an allowance for up to two rows of parking to be permitted between the building facade and the build-to line. This parking shall conform with the Form-Based Code S2-Retail Center requirements; except, that access to browsing lane parking should adhere to the Driveway Design standards provided in Frisco's Engineering Standards. (iii) Buildings shall be shifted interior to the development with an allowance for the entirety of the building's surface parking to be permitted between the building facade and the build-to line. Buildings shifted interior to the development shall front onto open space provided in accordance with Subsection (D)(2)d. Open Space. Table 2.05.06.1, Build-to Lines & Frontage Requirements Subdistrict Business | Mixed-Use Residential | Urban Center Build-to-line US 380 | 40-feet Dallas North Tollway | 50-feet Major Thoroughfare | 40-feet Minor Thoroughfare | 40-feet Commercial Collector | 30-feet Urban Collector | Zero Minimum Building Corner Frontage Requirement US 380 | 200-feet Major & Minor Thoroughfares Commercial Collector 2. The area between the street right-of-way and the build-to line shall be referred to as the Pedestrian Zone and largely reserved for landscaping, furnishings, and active transportation facilities that serve to create an inviting environment for bicyclists and pedestrians. (i) At a minimum, the Pedestrian Zone shall contain a meandering sidewalk with the width defined by the Hike & Bike Masterplan. However, the sidewalk along US 380 shall have a minimum width of 10-feet. (ii) The defined sidewalk width shall be maintained as a continuous clear path through the Pedestrian Zone regardless of the presence of any pedestrian plazas or other amenities. Landscape areas, street furniture, poles, fire hydrants, and similar obstructions shall not encroach into the minimum sidewalk width described above. 3. A minimum break of 50-feet shall be provided every 300-feet when development is backing a thoroughfare to ensure pedestrian access is provided into the development. Removal of this break is subject to Director of Development Services approval. b. Active transportation. Development shall provide a system of pedestrian walkways for interconnectivity between on-site features, and adjacent streets and parcels. c. Hike and bike trails. 1. Overlooks shall be provided at viewshed points such as elevated creek banks, high points, or where natural vegetation is present in accordance with the Engineering Standards and the Hike & Bike Master Plan and as approved by the Director of Parks & Recreation. 2. Trails shall provide connections to development at a minimum of one trail access point per 1,000 linear feet of creek corridor or as approved by the Director of Development Services and the Director of Parks & Recreation. d. Open space. Open space shall be developed in accordance with Subsection 4.13 Usable Open Space requirements. Open space placement and configuration shall adhere to the following additional provisions: 1. Natural features (i.e., creeks, outcroppings, view corridors, etc.) shall be preserved and incorporated into the development. 2. Open space shall be configured to provide pedestrian pathways across the development site with an emphasis on linking on-site gathering spaces to gateway zones and natural features. (3) US 380 Overlay landscaping. Development shall adhere to the landscape design provisions of this section. Should a provision not be addressed within this section, landscaping shall adhere to Subsection 4.02 Landscape Requirements. a. General landscape treatments. The application of landscape treatments within gateway zones, trail corridors, and roadsides, except for Urban Collector roadsides, shall adhere to the following provisions: 1. Landscape treatments shall be formalized in style within gateway zones, becoming less formal with clustered groupings of trees away from gateways. 2. Landscaping shall promote simple, mass planting arrangements (limiting plantings to large groupings of a single species of plant) for greater visual effect and ease of maintenance. 3. Native and adaptive grasses and perennials shall be utilized for gateways and roadsides including, but not limited to: Miscanthus Grass, Mexican Feather Grass, Love Grass, Gregg Salvia, Lantana, Purple Wintercreeper and Creeping Rosemary, or other native or adapted plants as approved by the Director of Development Services. b. Tree plantings. 1. Naturalized groupings of trees shall be provided within the Pedestrian Zone along all district thoroughfares, except for Urban Collectors. Trees shall be as close to equally distributed on both sides of the sidewalk as possible to provide symmetry and convey a sense of safety to users. 2. Urban collectors shall have formalized tree planting schemes along the edges and within tree grates or planters. Spacing of trees shall not exceed 30-feet on center. 3. Tree types shall consist of native and adaptive species including Red Oak, Chinquapin Oak, Cedar Elm, Lacebark Elm, Crape Myrtle, Desert Willow, Fosters Holly, and/or Redbud or alternatives with Director of Development Services approval. (4) US 380 Overlay exterior appearance of buildings and structures. a. A Facade Plan shall be submitted demonstrating the following requirements according to Subsection 6.16 Facade Plan Review. b. Architectural features, details, materials, and colors shall be compatible across individual building facades and with adjacent buildings. c. Building composition. 1. All buildings shall be architecturally finished on all four sides and shall be designed and built-in tripartite architecture so that they have a distinct base, middle, and top. [image] Figure 2.05.06.4, Tripartite Architecture d. Building elements. 1. Facades. Building facades shall be arranged to avoid the creation of a monotonous wall and create rhythm along the corridor and cross streets. (i) The facade plane shall be broken by a minor break at least every 60-feet. A minor break refers to an offset (inward or outward) of at least 12-inches and extending for at least five-feet. (ii) Building facades shall incorporate a variety of architectural elements such as offsets, overhangs, balconies, verandas, porte-cocheres and other features to add architectural character. These elements may be used to substitute for the offset required per Subsection 2.05.06(D)(4)d.1.(i). (iii) Facades shall employ design elements such as shade and shadow through reveals, surface changes, overhangs, and/or sunshades to provide visual interest on facades exposed to the sun. [image] The Shops at Clearfork - Fort Worth, TX [image] Kroger - Frisco, TX 2. Building corners. Building corners shall be emphasized through architectural features such as pedimented gabled parapets, cornices, awnings, arcades, colonnades, and balconies. 3. Ground floor facades. (i) Front facades visible from any public street right-of-way (excluding US 380), public way, primary pedestrian entrance, trail corridor, or social space shall have transparent windows covering no less than 75% of the ground floor facade area. (ii) All other facades shall incorporate transparent windows covering at least 20% of the facade area for all floors. (iii) Retail storefronts shall incorporate a transom, display window area, and minimum 18-inch watercourse at the base, unless an alternative is approved by the Director of Development Services. (iv) Shelter shall be provided for the pedestrian environment through the use of awnings, pergolas, arcades, and/or other elements. 4. Fenestration. (i) Windows and doors shall be proportional and appropriate to the building form. (ii) Opaque, tinted, or mirrored glass prohibited on the ground floor. 5. Building entrances. (i) Primary pedestrian entrances shall be located on all facades fronting a public street right-of-way, principal off-street parking area (including parking structures), trail corridor, and/or open space. (ii) Primary pedestrian entrances shall be defined and articulated by architectural elements such as lintels, pediments, pilasters, columns, porticoes, porches, overhangs, railings, balustrades, and other features as appropriate. e. Iconic buildings. Special design emphasis shall be placed on buildings located at primary and secondary gateway zone intersections. The buildings shall utilize unique architectural elements such as towers, spires or cornices; along with varied roof shapes and building heights. (5) US 380 Overlay building materials. a. Building shall be constructed of primary and secondary building materials in accordance with the percentages noted in the table below. Minimum % of Primary Materials | Minimum % of Secondary Materials | Materials* Primary | Secondary Facades fronting Public Streets, Public Ways, and/or Major Creeks | 80% | 20% | Clay fired brick, natural stone, cast stone, three-step stucco, marble, granite, curtain glass. Metal may be used subject to Director of Development Services approval | Wood, architectural metal panel, split-face concrete block, tile, pre-cast concrete panels, EIFS**, or cementitious-fiber clapboard*** All Other Facades | 65% | 35% * | Excluding doors and windows ** | Shall only be used nine feet above ground floor and only for trim and molding features *** | Shall only be used on ground floor facades of retail buildings, or mixed-use buildings incorporating storefronts for multiple tenants, with a minimum 50-year warranty, and be limited to no more than 10% of the total facade b. Materials shall wrap around corners a minimum of 15-feet (measured from the corner of the facade) and define the building form. Volume and material changes should be avoided along the same plane or at outside corners. c. Accent materials including natural stone, masonry, tile, terra cotta, metal or wood are encouraged along the ground floor base of retail storefronts and pedestrian intensive streets, entries, and other areas. d. Roof Systems: 1. Roofing materials visible from any public street right-of-way, principal pedestrian entrance, trail corridor, or social space shall be copper, factory finished standing seam metal, slate, synthetic slate, or similar material that provides a similar character or finish. (6) US 380 Overlay structured parking. a. Parking structures shall not dominate the built environment, and to the extent feasible, should be wrapped by the principal building which the structure serves to limit view of the structure from trail corridors, open space, or the adjacent public street rights-of-way of thoroughfares intersecting US 380. b. Except for building corner frontage zones, parking structures fronting US 380 may be constructed to the build-to line and may be counted toward the minimum frontage requirements. c. The exterior building materials of structured parking visible from any public street right-of-way, public way, principal pedestrian entrance, trail corridor, or social space shall be compatible with adjacent or abutting buildings. d. Notwithstanding the need for compatibility with adjacent or abutting buildings, parking structures shall be screened so that architectural and landscape components articulate the facade, hide parked vehicles, and shield lighting from within the structure. At a minimum, grates shall be provided on the first two levels of the parking structure. [image] [image] [image] (7) US 380 Overlay Gateway Zones. a. On each corner of the intersections identified within Figure 2.05.06.5 Overall Gateways Plan and Table 2.05.06.3 Gateway Locations, a gateway easement shall be provided meeting the following dimensional requirements noted below. The area dedicated towards the Gateway Zone may count towards the Usable Open Space requirement. Table 2.05.06.2, Gateway Development Standards Development Standard | Gateway Primary | Major Size | 11,250 square feet | 6,000 square feet Depth* | Min. 100-feet | Min. 75-feet *Measured perpendicularly from the corner clip ROW line. Table 2.05.06.3, Gateway Locations Number | Intersection Primary Gateways 1. | US 380 and Dallas North Tollway 2. | US 380 and Preston Road Major Gateways 3. | US 380 and FM 423 4. | US 380 and Championship Drive 5. | US 380 and Legacy Drive 6. | US 380 and Future Minor or Major Thoroughfare 7. | US 380 and Hillcrest Drive (Proposed) 8. | US 380 and Coit Road Trailhead Gateways 9. | US 380 and Panther Creek 10. | PGA Parkway and Parvin Branch 11. | Dallas North Tollway and Parvin Branch 12. | Preston Road and Parvin Branch [image] (8) US 380 Overlay Bridges (excludes TXDOT & NTTA Bridges). a. Bridges shall have decorative, stone-wrapped pilasters with lighting and enhanced pedestrian railing; b. Bridge support columns shall be designed with reveals and/or texture rather than standard smooth, cylindrical column finishes; c. Vertical clearance underneath any bridge structure shall be a minimum of 10-feet above finished grade where Hike & Bike Trails are required subject to the Director of Engineering Services and the Director of Parks & Recreation; d. Overlooks may be associated with bridges where appropriate conditions exist; and e. Shall conform to the Engineering Standards.
( Ordinance 2022-01-01 adopted 1/4/2022 )
Ask a question about Frisco law
Corpus searches the Frisco sections it holds and shows the ones that match, with their citations. Free, no sign-in.
