For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 94-302 — Definitions

Code of Ordinances, City of Frisco, Texas (Frisco City Code, Home Rule Charter and Code Appendix current through Ordinance 2026-10-64 adopted October 20, 2026 (eCode360 publication FR6313, scraped 2026-11-18)) · Frisco City Code § 94-302

Corpus is an independent public-information project, not the official City of Frisco website. Stable reference: corpuslaw.us/code/57319209-b426-4cae-8184-e63f5c6a1add

§ 94-302: Definitions.

The following definitions shall apply in the interpretation and enforcement of this article and the following terms shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning. Air gap. A physical separation between the free-flowing discharge end of a potable water supply piping and/or appurtenance and an open or non-pressure receiving vessel, plumbing fixture or other device. An approved air-gap separation shall be at least twice the diameter of the supply pipe measured vertically above the overflow rim of the vessel, plumbing fixture or other device, in no case less than one (1) inch and shall comply with the plumbing code. Auxiliary water supply. Any water supply other than a city-approved water supply source, including water from another public water supply or from a natural source, including but not limited to, wells, cisterns, springs, rivers, streams, used waters or industrial fluids. Backflow. The flow in the direction opposite to the normal flow or the introduction of any foreign liquids, gases or other substances into the water system of the city's water. Backflow prevention assembly. An assembly to counteract backpressure or prevent backsiphonage that meets the standards contained in the plumbing code. For the purposes of this article, the only approved assembly shall be a reduced pressure backflow assembly ("RPBA"). Backflow prevention assembly tester. An individual licensed in accordance with Texas Commission on Environmental Quality ("TCEQ") rules, as amended, for the purpose of testing backflow prevention assemblies. Building official. The officer or other designated authority charged with the administration and enforcement of this article or other duly authorized city representative. City or City of Frisco. The City of Frisco and the city's officers and employees. Contaminants. Any foreign material, solid or liquid, not common to the potable water supply which makes or may make the water unfit or undesirable for human or animal consumption. Contamination. The admission of contaminants into the potable water supply system. Cross connection. Any connection, physical or otherwise, between a potable water supply system and any plumbing fixture, or any tank, receptacle, equipment or device, through which it may be possible for any non-potable, used, unclean, polluted and contaminated water, or other substances, to enter into any part of such potable water system under any condition or set of conditions. Director of public works. The director of public works or his or her designee. Existing work. A water well or water system which had been installed prior to the effective date of this article. Health hazard. A cross connection, potential contamination hazard, or other situation involving any substance that can cause death, illness and spread of disease or has a probability of causing such effects if introduced into the potable drinking water supply. Nonpotable water. A water supply that has not been approved for human consumption by the city. Person. Any individual, firm, partnership, joint adventure, association, club, fraternal organization, joint stock company, corporation, cooperative, estate, trust, receiver, trustee, syndicate or any other group or combination acting as a unit. Plumbing inspector. Any person hired by the city for the purpose of inspecting work and installation in connection with health and safety laws as provided in, or referred to in, this article. Potable water. Any water supply intended or used for human consumption or other domestic use. Premises or property. Any real, improved or personal property that is connected to the city-approved water supply source. Premises isolation. The practice of protecting the potable water supply by installing a backflow prevention assembly at or near the point where water enters the premises. This protection does not provide backflow protection for personnel inside the premises. Public sewer. A common sewer directly controlled by the city or other public authority. Reduced pressure backflow assembly (RPBA). An assembly containing two (2) independently acting approved check valves together with a hydraulically operating, mechanically independent pressure differential relief valve located between the check valves and at the same time below the first check valve. The unit includes properly located resilient-seated test cocks and two tightly-closing resilient-seated shutoff valves at each end of the assembly. Sanitary sewer. A pipe which carries wastewater and excludes storm, surface water and groundwater. Septic tank. A watertight receptacle which receives the discharge of a drainage system or part thereof, which is designed and constructed so as to separate solids from the liquid, digest organic matter through a period of detention, and allow the liquids to discharge into the soil outside of the tank through a drain field, disposal or perforated piping. Service connection. The point of delivery at which the water purveyor loses control of the water. Testing or reporting deficiencies. Incomplete or inaccurate backflow prevention assembly test results or reports filed with the city pursuant to this article; the use of inaccurate gauges; or the use of improper operational certification methods. Thermal expansion. Heated water that does not have any space to expand. Water main. A water distribution pipe for public or community use. Water purveyor. The operator of a potable water system supplying at least fifteen (15) service connections or servicing at least twenty-five (25) individuals at least sixty (60) days out of the year. Water wells. Bored wells, dug wells or driven wells developed into the underground soils, which are to produce water for private use. Water wells are prohibited unless approved under the provisions of this article.

( Ordinance 19-05-39 adopted 5/21/19 )

Ask a question about Frisco law

Corpus searches the Frisco sections it holds and shows the ones that match, with their citations. Free, no sign-in.