§ 30.41: Application to existing electrical systems and equipment.
(A) Additions, alterations or repairs. (1) Additions, alterations or repairs may be made to any electrical system and equipment without requiring the entire existing electrical system to be upgraded to meet this Code, provided that any addition, alteration or repair conforms to the requirements for a new electrical system and provided further that no hazard to life, health or safety will be created by such additions, alterations or repairs. (2) Minor additions, alterations and repairs to existing electrical systems and equipment may be made in accordance with the law in effect at the time the original installation was made, when approved by the Building Official. (B) Existing installations. Electrical systems and equipment lawfully in existence at the time of the adoption of this Code may have their use, maintenance or repair continued if the use, maintenance or repair is in accordance with the original design and no hazard to life, health or property has been created by such electrical system and equipment. (C) Change in building occupancy. Electrical systems and equipment which are a part of any building or structure undergoing a change in use or occupancy, as defined in the Building Code, shall comply with the requirements of this Code which are applicable to the new use or occupancy. (D) Maintenance. All electrical systems and equipment, both existing and new, and all parts thereof shall be maintained in a proper operating condition in accordance with the original design and in a safe and hazard-free condition. All devices or safeguards which are required by this Code shall be maintained in conformance with this Code. The owner or his designated agent shall be responsible for the maintenance of the electrical system. To determine compliance with this subsection, the Building Official may cause any electrical system to be reinspected. (E) Moved building. Electrical systems and equipment which are a part of buildings or structures moved into or within the City shall comply with the provisions of this Code for new installations.
( Ordinance 5977 , sec. 4, adopted 3/7/06 )
Ask a question about Garland law
Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.