For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30.51 — Electrical registrations, licenses, and supervision of work

Code of Ordinances of the City of Garland, Texas (Garland Code of Ordinances, Home Rule Charter and Garland Development Code current through Ordinance 7697 adopted August 17, 2026 (eCode360 publication GA6318, scraped 2026-11-17)) · Garland Code of Ordinances § 30.51

Corpus is an independent public-information project, not the official City of Garland website. Stable reference: corpuslaw.us/code/e75e5cc4-a79e-4638-943e-5f6adb034753

§ 30.51: Electrical registrations, licenses, and supervision of work.

(A) Any person providing services as an electrical contractor in the City must register with the Building Inspection Department as a contractor. To register with the City as a contractor, application shall be made in writing on forms furnished for that purpose and filed with the Building Official. The application shall show the contractor’s name, local address and telephone number, a copy of the applicant’s state electrical contractor’s license, and such other information as may reasonably be required to properly identify the contractor. Such application shall be accompanied by the fee prescribed in the fee schedule located in section 30.301 of this Code. (B) Except as provided in subsections (C) and (D), all provisions of the Texas Electrical Safety and Licensing Act, found in the State Occupations Code, title 8, chapter 1305 and the Administrative Rules of the state department of licensing and regulation, 16 Texas Administrative Code, chapter 73 shall be in full force within the City. (C) Any electrical license or registration issued by the City which has not expired by the adoption date of the ordinance codified in this article shall remain valid and in full effect until the expiration date of said license. Upon the expiration date of said license, the City will not renew or honor the rights previously granted by the license. When all such licenses are expired, the electrical licensing program of the City shall cease. (D) Municipal Electrical Maintenance License. Pursuant to subchapter E, "Regulation of Electricians by Local Governments," section 1305.201, "Municipal or Regional Regulation," of the Texas Occupations Code, an electrical maintenance technician license may be issued by the City to allow a governmental entity located within the City to employ persons as electrical maintenance technicians, which are qualified and authorized by this Code to maintain and make minor repairs to electrical systems on property that is owned or controlled by the governmental entity. (1) Qualifications. Persons performing electrical work under this section in their capacity as an employee of a governmental entity may apply for a license as an electrical maintenance technician with the City. Applicants applying for a municipal electrical maintenance technician license must complete eight (8) hours of training approved by the Building Official. (2) Limitations of work. Work that may be performed under this license by an electrical maintenance technician shall be limited to the maintenance of, repair or replacement of devices or lighting fixtures, having the same characteristics as the existing devices or fixtures, in or on existing outlets and shall include, but not be limited to the following: (a) 120-volt receptacles of all types; (b) 240-volt 3-wire and 4-wire appliance receptacles. Replacement of these receptacles shall be limited to like configuration and amperage receptacles; (c) Resetting or replacement of overcurrent devices and safety switches of only the same voltage, current, ampere interrupting capacity (AIC) including: (i) One, two, or three pole circuit breakers not exceeding 200-amps at 480-volts; (ii) One, two, or three pole safety switches (fused or non-fused) not to exceed 200-amps at 480-volts; and (iii) Fuses not to exceed 200-amps at 480-volts; (d) Photocells and time clocks not to exceed 480-volts nominal; (e) Range hoods, ranges, ovens, disposals, dryers, ice machines, water heaters, walk in coolers, chilled water fountains, chilled bottle fillers, and dishwasher motors; (f) Lighted exit signs, emergency lights, interior, exterior lighting and switches not to exceed 480-volts nominal; (g) Ceiling fans on approved boxes with proper bracing; (h) Wiring to low voltage devices with 120-volt connections; (i) Bathroom-type exhaust vents; (j) Card access systems, electronic door strikes, security system control boards and wiring, electric gates, overhead doors, and automatic door operator repair or replacement; (k) Thoroughfare lighting, traffic signals, intelligent transportation systems, parking lot lighting and telecommunications controlled by a governmental entity; (l) Electrical connections supplying heating, ventilation, replacing three phase 480 volt motors, and cooling and refrigeration equipment, including Variable Frequency Drives (VFD) and any required disconnect for the equipment; (m) Maintenance, alteration, or repair of elevators, escalators, or related equipment, excluding any required power source, regulated under chapter 754, Health and Safety Code; (n) Operating, maintaining, repairing, and replacing back-up power systems such as uninterrupted power systems and backup generators up to 480 volt 1750 KVA; (o) Landscape irrigation installers, as necessary to perform the installation and maintenance of irrigation control systems, and landscapers, as necessary to perform the installation and maintenance of low-voltage exterior lighting and holiday lighting excluding any required power source; (p) The maintenance, alteration, or repair of a pool-related electrical device by, or pool-related electrical maintenance performed by, an employee of a governmental entity on a pool owned or operated by the governmental entity; and (q) Installation, erection, repair, or alteration of Class 1, Class 2, or Class 3 remote control, signaling, or power-limited circuits, fire alarm circuits, optical fiber cables, or communications circuits, including raceways, as defined by the National Electrical Code. (3) Expiration. A municipal electrical maintenance license issued under this section, shall remain valid until such time the permitted individual is no longer employed by the governmental agency for which the license was issued. (4) Fees. There shall be no application fee for a municipal electrical maintenance license. Applicants, or their employers, shall be responsible for paying any fees associated with the mandated 8-hour training.

( Ordinance 5977 , sec. 4, adopted 3/7/06 ; Ordinance 6624 , sec. 2, adopted 6/18/13 ; Ordinance 7533 adopted 6/4/2024 )

Ask a question about Garland law

Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.