§ 30-161 — Director of public works
Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 30-161
Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/1806422c-4137-4c6d-884e-afcd78b73175
Sec. 30-161. - Director of public works.
(a) Authority and responsibility. The director, in accordance with this article and title 30, chapter 290 of the Texas Administrative Code, both as amended, is responsible for enforcing the requirements of this article and may establish policies to implement the purposes of this article (30 Texas Admin. Code § 290.44(h)(1)(B)(iii); V.T.C.A., Health and Safety Code ch. 341, subch. C). (b) Adequate protection determination. To ensure adequate protection in individual cases, the director may assess and determine the degree of hazard to the city's potable water system posed in the case of individual connections, customers or users. When the director determines that a backflow prevention assembly is required for the protection of the city water system, the director will require the customer, at the customer's expense, to properly install an approved assembly at each service connection or hazard point. Notice of such requirement shall be given in accordance with section 30-168 of this article (30 Texas Admin. Code (TAC) § 290.44(h)(1)(B)(iii)). (c) Certified testing required. In accordance with the TCEQ's Rules, the director shall require a certified testing report for all required and testable assemblies where an actual or potential hazard has been determined to exist in accordance with subsection 30-161(d) in the following instances: (1) Prior to providing continuous water service to new construction; (2) On any existing service when the director has reason to believe that cross connections or other unacceptable plumbing practices increase the risk of actual or potential contamination hazards entering into the city water system; (3) After any installation, repair, relocation, alteration, or addition to a customer's system that may affect the system's compliance with this article; and (4) At other times as provided by this article. (30 Texas Admin. Code (TAC) § 290.44(h)(4)) (d) Testing by city. City personnel, as directed by the director, may perform periodic tests on assemblies at random locations to ensure that acceptable test standards are being followed by certified testers and randomly select and tag assemblies in a manner that will determine if the assemblies have been tested as required. (e) Authority to compel report production. The director may require from any person the submission of any records relating to the installation, maintenance, repair or testing of backflow prevention assemblies performed in accordance with this article (30 Texas Admin. Code (TAC) § 290.44(h)(1)(B)(ii)). (f) Authority to refuse or terminate service. The director may, upon approval of the city manager, refuse to initiate service or discontinue present service to any customer where the director determines that: (1) an actual or potential sanitary hazard in the customer's system exists; and/or (2) adequate protection against backflow has not been provided or reported in accordance with this article. Notice of terminating service is not required where the actual or potential threat of contamination endangers the health, safety and welfare of the city water system and the customers the system serves (30 Texas Admin. Code (TAC) § 290.46(j)(2)). (g) Authority to revoke certified tester registration. The director may revoke a certified tester's registration in the following cases: (1) Failure to register the serial number or have the gauge tested for accuracy annually; (2) Use of a test gauge that does not meet the manufacturer's calibration standards in preparation of a city backflow test and maintenance report; (3) Two (2) testing or reporting discrepancies within a one-year period, beginning on the date of the first discrepancy, including: (i) False, incomplete, or inaccurate reporting of test completion or certification of a backflow prevention assembly; (ii) Use of inaccurate gauges; (iii) Improper operational certification methods; or, (iv) Failure to comply with subsections 30-163(b) or (d) of this article; (4) Failure to maintain licensure or registration with TCEQ; (5) Failure to comply with subsections 30-163(e) or (f) of this article; or, (6) Conviction of a violation of this article. (30 Texas Admin. Code (TAC) § 290.44(h)(4)) Revocation under this paragraph is effective upon receipt of written notice from the director sent via certified mail, return receipt requested. Receipt is presumed to occur five (5) calendar days following the date the notice is mailed. Non-receipt of the notice does not affect the validity of a revocation order. Written notice under this paragraph shall provide specific written findings justifying revocation. Registrations for certified tester's that have had a registration revoked shall not be accepted for a period of one (1) year following the effective date of revocation. (h) Appeal of registration revocation. A request for appeal and reconsideration of registration revocation by a certified tester shall be delivered to the city manager within fifteen (15) calendar days of receipt of the revocation notice and shall specifically contest or justify the director's findings as outlined in the revocation notice. The city manager shall have fifteen (15) calendar days to reconsider revocation and shall then issue a written final determination via certified mail, return receipt requested.
(Ord. No. 08-040, § II, 5-27-08)
Ask a question about Killeen law
Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.
