§ 30-163 — Certified backflow prevention assembly testers
Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 30-163
Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/0f883d24-ac88-4e67-94ee-81a8c7a435f0
Sec. 30-163. - Certified backflow prevention assembly testers.
(a) Registration of certified testers. Each person qualified to perform services as a certified tester for a city water system customer shall submit a completed city registration form to the director prior to performing any services regulated under this article. Test results or certification of the performance of other services shall not be accepted if the tester is not currently registered with the director. The director shall maintain a current list of registered certified testers, and will make this list available to city water system customers upon request. Registrations will be valid for one (1) year and must be renewed annually. (b) Testing equipment. The certified tester shall furnish the city with the serial number of the tester's test kit, and the tester's test gauge must be tested when purchased and annually thereafter, or more frequently as required by the director, to be in compliance with the University of Southern California's Manual of Cross Connection Control (latest edition) or the American Water Works Association Manual of Cross Connection Control requirements (Manual M14, latest edition). The certified tester must maintain the test gauge within a two (2) percent accuracy deviation and retain test results for three (3) years from the date of any such test. All test results shall be made available to the director upon written request or as provided for by this article (30 Texas Admin. Code (TAC) § 290.44(h)(4)(A) and (B)). (c) Accountability of certified tester. The certified tester is responsible for the competency and accuracy of all tests and reports certifying assemblies to be operating within specifications performed or submitted by the certified tester, and for all work done by any persons under the direction or control of the certified tester. All work performed by a certified tester's assistants must be performed in the tester's presence. Certified testers shall certify that all backflow prevention assemblies comply with the specifications provided in the University of Southern California's Manual of Cross Connection Control (latest edition) or the American Water Works Association Manual of Cross Connection Control requirements (Manual M14, latest edition) and that such assemblies are otherwise in compliance with this article. (d) Reporting and record keeping requirements. A City of Killeen test and maintenance report form must be completed by a certified backflow prevention assembly tester for each assembly tested. The signed and dated original must be submitted to the director for record keeping purposes. Only City of Killeen test and maintenance report forms will be accepted. All test and maintenance reports shall be retained for at least three (3) years from the date of any such test, and shall be made available to the director upon written request or as provided for by this article (30 Texas Admin. Code (TAC) § 290.44(h)(1)(C)). (e) Immediate notification required from a certified tester. If a backflow prevention assembly test fails or an assembly malfunctions and the actual or potential hazard of contamination is not immediately curable through repair or replacement, the certified tester shall notify the director and the customer immediately in person or by telephone. This notification shall also be submitted in writing within five (5) calendar days. If the failure or malfunction of a backflow prevention assembly is not immediately curable through repair or replacement, the director upon notification, shall take all necessary steps, including the immediate cessation of water service through the assembly, to prevent the possible contamination of the city water system. (f) Alteration of backflow assembly. It is a violation of this article for a certified tester to alter the design, material, or operational characteristics of a backflow prevention assembly during testing, repairing or maintaining the assembly without the prior written approval of the director. (g) Qualified. Certified backflow prevention assembly testers are qualified to test and repair assemblies on any domestic, commercial, industrial, or irrigation service. However, certified testers shall only test and repair assemblies on fire lines if they are permanently employed by an approved fire line contractor as required by the State of Texas Fire Marshall's office (30 Texas Admin. Code (TAC) §§ 290.44(h)(1)(A)(i) and (ii)).
(Ord. No. 08-040, § II, 5-27-08)
Ask a question about Killeen law
Corpus searches the Killeen sections it holds and shows the ones that match, with their citations. Free, no sign-in.
