§ 31-115.02 — Definitions
Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Code of Ordinances § 31-115.02
Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/8358f297-2025-4d46-a732-a0763673dc23
Sec. 31-115.02. - Definitions.
For the purposes of this division, the following definitions shall apply unless the context clearly indicates or requires a different meaning. If a word or term used in this division is not contained in the following list, its definition, or other technical terms used, shall have the meanings or definitions listed in the most recent edition of the Manual of Cross Connection Control published by the Foundation for Cross Connection Control and Hydraulic Research, University of Southern California ("USC"). Approved backflow prevention assembly or backflow assembly or assembly means a testable assembly to counteract backpressure and/or prevent back-siphonage. This assembly must appear on the list of approved assemblies per appendix A. Auxiliary supply means any water source or system other than the City of Laredo Utilities System. Backflow means the undesirable reversal of flow of water or mixtures of water and other liquids, gases, or other substances into the distribution pipes of the potable supply of water from any source or sources. Certified backflow assembly tester shall mean a person who has successfully completed and maintains all requirements as established by the State of Texas to be a backflow prevention assembly tester in the state. Certified cross connection control inspector shall mean a person who has successfully completed and maintains all requirements as established by the State of Texas to be a customer service inspector in the state. City shall mean the City of Laredo. Contamination means the entry into or presence in a public water supply system of any substance which may be deleterious to health and/or potability of the water. Cross-connection means any physical arrangement where a potable water supply is connected, directly or indirectly, with any other non-drinkable utilities system or auxiliary system, sewer, drain conduit, swimming pool, storage reservoir, plumbing fixture, swamp coolers or any other device which contains, or may contain, contaminated water, sewage or other liquid of unknown or unsafe quality which may be capable of imparting contamination to the utilities system as a result of backflow. Bypass arrangements, jumper connections, removable sections, swivel or changeover devices or other temporary or permanent devices through which or because of which backflow may occur, are considered to be cross-connections. Degree of hazard means the non-health hazard or health hazard classification that shall be assigned to all actual or potential cross-connections. Double check valve backflow prevention assembly, double check assembly, double check or DCVA means an assembly which consists of two (2) independently-operating check valves which are spring-loaded or weighted. The assembly comes complete with a resilient seated shut-off valve on each side of the checks, as well as test cocks to test the checks for tightness. Double check valve assembly or DCVA means an assembly which consists of two (2) independently operating check valves which are spring-loaded or weighted. The assembly comes complete with a shut-off valve on each side of the checks, as well as test cocks to test the checks for tightness. It shall also be provided with a factory bypass arrangement with a meter and a minimum of an approved double check assembly. This is primarily used for fire line application. Health hazard means an actual or potential threat of contamination of a physical, chemical, or biological nature to the public potable utilities system that would be a danger to health or has a high probability of causing such effects if introduced into the utilities system. In-premises protection means the appropriate backflow prevention within the consumer's plumbing at or near the point at which the actual or potential cross connection exists. Inspector means a TCEQ-certified cross-connection inspector, either employed by or contracted by the City of Laredo. Mobile units shall mean units that are temporary in nature, connecting to the utilities system through a legally-permitted hydrant, hose bibb, or other appurtenance of a permanent nature that is part of the City of Laredo Utilities System. Examples can include but are not limited to the following: water trucks, pesticide applicator vehicles, chemical mixing units or tanks, waste hauler's trucks or units, sewer cleaning equipment, carpet or steam cleaning equipment other than homeowner use, or any other mobile equipment or vessel that poses a threat of backflow in the City of Laredo Utilities System. Uses that are excluded from this definition are recreational vehicles at assigned sites or parked in accordance with other City of Laredo policies pertaining to recreational vehicles and homeowner devices that are used by the property owner in accordance with other provisions of this, or other, City of Laredo policies pertaining to provision of water service to a premises. Non-health hazard shall mean the classification assigned to an actual or potential cross connection that could allow a substance that may be aesthetically objectionable, but not hazardous to one's health, to backflow into the potable water supply. Person(s) shall mean a natural person (individual), corporation, company, city, partnership, firm, limited liability company, joint venture company, and other such entity. Premises means any piece of property to which water service is provided, including, but not limited to, all improvements, mobile structures and other structures located upon it. Premises isolation means the appropriate backflow prevention at the service connection between the utilities system and the premises. This location will be at or near the property line and downstream from the service connection meter. Reduced pressure principle backflow prevention assembly or reduced pressure principle assembly or RPBA shall mean an assembly containing two (2) independently-acting approved check valves together with a hydraulically-operated, mechanically-independent pressure differential relief valve located between the check valves, and at the same time, below the first check valve. The assembly shall include properly located test cocks and two (2) tightly closing shut-off valves. Reduced pressure detector assembly or RPDA shall mean an approved assembly consisting of two (2) approved reduced pressure backflow assemblies, set in parallel, equipped with a meter on the bypass line to detect small amounts of water leakage or use. The assembly should include properly-located test cocks and two (2) tightly closing shut off valves. This is primarily used for fire line application. Resident means a person or persons living within the area(s) served by the City of Laredo Utilities System. SOP manual shall mean the utilities department standard operating procedures and guidance manual. Supervisor shall mean the utilities supervisor or his/her designee. TAC shall mean Texas Administrative Code. TCEQ shall mean Texas Commission on Environmental Quality. Thermal expansion means the pressure created by the expansion of heated water. Utilities system shall refer to the geographical area that receives drinking water from the City of Laredo water system, regardless of city limits. This also includes wells, treatment mechanisms or processes, pumping stations, reservoirs, supply trunk or feeder lines, service lines, meters and all other appurtenances, device lines and items necessary for the operation of the system and to supply potable water service to individual property or premises.
(Ord. No. 2025-O-103, 6-2-25)
Ask a question about Laredo law
Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.
