Sec. 31-140. - Fire hydrant meters.

(a) System connection and water use. The city utilities department issues on-location fire hydrant meters for water usage on projects to contractors/customers on a short-term basis. Water taken from fire hydrants may be used only for non-potable, non-recreational purposes within the utilities department service area. The use of non-potable water taken from fire hydrants for swimming pools is prohibited. Fire hydrant meters may not be used for long-term irrigation or other uses where a permanently installed meter would be appropriate. No garden hose adaptors will be allowed to be connected to the two (2) inch fire hydrant meter. The utilities director may allow another size of meter as a fire hydrant meter. The utilities director may remove any fire hydrant meter due to pressure issues. (b) Application process and inspection. The contractor/customer shall complete a fire hydrant meter application stating the exact location for the meter installation. The applicant shall provide the reason for the meter and an approximate time frame the meter will be in service. Once approved, the contractor/customer must pay the applicable fees. The use of a meter other than what is indicated on the application shall cause the meter to be confiscated immediately. Failure to comply with one (1) or more of the terms and conditions shall be cause for terminating the account. Under a standard fire hydrant meter request, the applicant may request the use of any fire hydrant from the utilities department's designated network fire hydrants. The utilities department staff will review such requests on a case by case basis and a decision shall be issued within five (5) business days of receiving the request. The utilities department reserves the right to refuse to issue a fire hydrant meter permit to any applicant or to require an applicant to pay all current charges on the applicant's utilities account as a condition to the issuance of a fire hydrant meter. The utilities department can inspect fire hydrant meters at any time and the account holders shall make provisions for such inspections. The account holder shall use the backflow preventer provided with the fire hydrant meter at all times to protect the city's water supply. Removal of the backflow prevention device shall be cause for confiscating the fire hydrant meter and terminating the account. Any contractor, customer, builder, or person found connected to the water system without the city's approval shall be considered an illegal connection and subject to a five hundred dollar ($500.00) illegal connection fee. This includes if the contractor/customer moves the meter from the location where the utilities staff installed it. Upon request, the fire hydrant meter can be transferred when the contractor/customer completes a relocation of a fire hydrant meter form for the new project location and time frame. Payment of all applicable fees is required. (c) Fees and charges. (1) A deposit of the actual cost of the meter is required for each fire hydrant meter account. (2) The nonrefundable installation fee for each fire hydrant meter account is based on actual cost. (3) All fire hydrant meter(s) shall be charged a minimum monthly charge of four hundred thirty dollars ($430.00) which will provide up to fifty-three thousand seven hundred fifty (53,750) gallons. Anything above the minimum consumption will be charged as established in section 31-138, water rates. (4) A contractor/customer may request for an on-location fire hydrant meter. If no fire hydrant exists at the location, the total cost for the installation of a new fire hydrant and meter for on-location service is the actual costs of a fire hydrant, fire hydrant installation, fire hydrant meter deposit and fire hydrant meter installation. (5) The account holder shall be required to remit payment for all water withdrawn from fire hydrants on a monthly basis. A late fee of five (5) percent or five dollars ($5.00) whichever is greater is charged to the balance owed on the account on the due date. (6) Fire hydrant flow test (if required) is one hundred fifty dollars ($150.00). (7) Customers/contractors have the option to construct a water tap at the location where they are requesting a fire hydrant meter. If approved, the fire hydrant meter will be placed at the tap instead of a fire hydrant. All fees and charges will remain the same as a fire hydrant meter. (d) Loss, damage and payment. The fire hydrant meter is the responsibility of the contractor/customer who will be held responsible for charges and fees if the meter is lost, stolen or damaged. Meters reported stolen must be accompanied by a police report. Deposits for lost or stolen meters will be forfeited for the meter cost and estimated consumption charges will be billed. Damages to the meter will also be deducted from the deposit. A new deposit and fire hydrant meter installation fee will be required if the customer/contractor wants to continue using a fire hydrant meter.

(Ord. No. 2016-O-086, 8-1-16; Ord. No. 2018-O-026, § 1, 2-5-18; Ord. No. 2024-O-205, § 1, 10-28-24)

Ask a question about Laredo law

Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.