Sec. 33-72. - New long term storage facility standards.
All new long term storage facilities shall meet and maintain the following standards: (1) Monitoring systems. Hazardous materials which are liquid or solid at standard temperature and pressure (STP) shall be stored with a monitoring system capable of detecting that the hazardous material stored in the primary containment has entered the secondary containment and according to the following: a. Visual inspection of the primary containment is the preferred monitoring method. However, other monitoring devices which must include attention-getting visual and/or audible alarms may be required by the environmental services department; b. Where the secondary containment may be subject to the intrusion of water, a means of monitoring for such water shall be required. (2) Containment. Hazardous materials which are liquid or solid at STP shall be stored in a primary and secondary level of containment which shall be installed and maintained according to the following: a. All primary containment shall: 1. Be product-tight; 2. Have overfill protection which may include an overfill prevention device and/or an attention-getting high level alarm. b. The secondary containment shall be: 1. Constructed of materials of sufficient thickness, density, and composition so as not to be structurally weakened as a result of contact with the discharged hazardous materials and so as to be capable of containing hazardous materials discharged from a primary container for a period of time equal to or longer than the maximum anticipated time sufficient to allow recovery of the discharged hazardous material; 2. Where only one (1) primary container is installed, large enough to contain at least one hundred ten (110) percent of the volume of the primary container; 3. Where multiply primary containers are installed in a secondary containment, large enough to contain one hundred fifty (150) percent of the volume of the largest primary container placed in it, or ten (10) percent of the aggregate internal volume of all primary containers in the secondary containment, whichever is greater; 4. If the secondary containment is open to rainfall, then it must be able to additionally accommodate the volume of a twenty-four-hour rainfall as determined by a twenty-five-year storm history. c. Laminated, coated, or clad materials shall be considered single-walled and shall not be construed to fulfill the requirements of both primary and secondary containment. d. A person or entity may apply to the hazardous materials management permit office on a form provided by the environmental services department for a variance from the secondary containment requirements and the applicant must demonstrate all of the following: 1. The requirement of secondary containment creates an unusual and particular hardship; 2. An equivalent degree of protection is provided by the proposed alternative; and 3. The proposed alternative has been appropriately certified as providing an equivalent degree of protection by an independent engineer retained in accordance with section 33-19. e. The environmental director or his/her designee may grant a variance from a secondary containment requirement based only on the special circumstances of the storage facility and not on a class or category of storage facilities. The decision of the environmental director or his/her designee shall be according to sections 33-45, 33-46 and 33-48. f. A variance from a secondary containment requirement may be denied according to section 33-53, but the applicant may appeal the decision according to section 33-54. (3) Separation of materials. Materials that in combination may cause a fire or explosion, or the production of a flammable, toxic, or poisonous gas, or the deterioration of a primary or secondary container shall be separated in both the primary and secondary containment so as to avoid intermixing. (4) Drainage systems. Drainage shall be installed and maintained according to the following: a. All precipitation shall be controlled in a manner as to prevent hazardous materials from being discharged; b. All drainage systems shall be such that the flow of the drain can be controlled; c. All storage facilities shall contain a means of removing the water by the owner or operator; d. Any water removal system shall also provide for a means of analyzing the removed water for hazardous substance contamination and a means of disposing of the water, if so contaminated, at an authorized disposal facility.
(Ord. No. 97-332, § 1, 1-5-98; Ord. No. 2002-O-287, § 1, 11-4-02)
Ask a question about Laredo law
Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.