Sec. 33-79. - Hazardous materials management plans.

(a) Submittal. All long term storage facilities shall have a current written plan which must be filed with the permit application to be known as a hazardous materials management plan (HMMP) which shall demonstrate the safe storage and handling of hazardous materials. (b) Amendments. The HMMP may be amended at any time with the consent of the environmental services department to keep the plan current. (c) Approval. Approval of the HMMP shall not mean that the environmental services department or the city has made an independent determination of the adequacy of that which is described in the HMMP. (d) Contents. Unless the storage facility is a long term minimal storage facility under section 33-80, the HMMP shall include the following: (1) General information. The HMMP shall contain the name and address of the storage facility and business phone number of the applicant, the name and titles and emergency phone numbers of the primary response person and an alternate, the number of employees, number of shifts, hours of operation, and principal business activity. (2) General site plan. The HMMP shall contain a map drawn at a legible scale and in a format and detail determined by the environmental services department, which shall include, but not be limited to, the location of all building and exterior storage facilities, permanent access ways, evacuation routes, chemical loading areas, parking lots, internal roads, equipment cleaning areas, storm and sanitary sewer accesses, emergency equipment, and adjacent property uses. The exterior storage areas shall be identified with the hazard classes and the maximum quantity per hazard class of hazardous material stored. The environmental services department may also require information as to the location of wells, flood plains, surface water bodies, and/or general land uses (schools, hospitals, institutions, residential areas) within one (1) mile of the facility boundaries. (3) Building floor plan. a. The HMMP shall contain a building floor plan drawn at a legible scale which shall include, but not be limited to, the location of each hazardous materials storage facility or storage system, including all interior, exterior, and underground storage systems, and shall indicate rooms, doorways, corridors, exits, fire related assemblies with their hourly rating, location of liquid tight rooms, and evacuation routes. In addition, the plan shall indicate the location of emergency equipment related to each storage facility, and the general purpose of the other areas within each facility. For each storage facility, the map shall contain the following information which shall be identified in a coded manner (together with its key): 1. A floor plan to scale and the permit quantity limit; 2. For each nonwaste hazardous material which is stored or handled in a quantity greater than the quantities specified in the definition for a long term minimal storage facility, the general chemical name, common/trade name, major constituents for mixtures, United Nations (UN) number, CAS number and physical state. For each waste hazardous material stored in any quantity within the storage facility, the presence of wastes shall also be indicated; 3. For all hazardous materials, including wastes, stored in each storage facility, the hazard class or classes and the quantity range for each such class, aggregated within each storage facility, in the following ranges: Quantity Range Number | Range Amounts 1 | Less than 500 pounds for solids Less than 55 gallons for liquids Less than 200 cubic feet at STP for compressed gases 2 | Between 500 and 4,999 pounds for solids Between 55 and 549 gallons for liquids Between 200 and 1,999 cubic feet at STP for compressed gases 3 | Between 5,000 and 24,999 pounds for solids Between 550 and 2,749 gallons for liquids Between 2,000 and 9,999 cubic feet at STP for compressed gases 4 | Between 25,000 and 49,999 pounds for solids Between 2,750 and 5,499 gallons for liquids Between 10,000 and 19,999 cubic feet at STP for compressed gases 5 | 50,000 pounds or more for solids 5,500 gallons or more for liquids 20,000 cubic feet or more at STP for compressed gases 4. For materials not regulated under this section, but regulated under the Uniform Fire Code, such as radioactives or cryogens, the environmental services department may require that the hazard class or classes and the quantity range of each such hazard class, using the quantity ranges listed in subsection 3. above, be provided; 5. For tanks, the capacity limit of each tank, and the hazardous material contained in each tank by general chemical name, common/trade name, major constituents for mixtures, United Nations (UN) or North America (NA) number, if available, and physical state. b. The storage facility map shall be updated annually or whenever an additional approval is required for the facility or whenever the HMIS is required to be amended pursuant to section 33-83. (4) Inventory statement. A hazardous materials inventory statement prepared in accordance with section 33-83. (5) Separation of materials. A description of the methods to be utilized to ensure separation and protection of stored hazardous materials from factors which may cause a fire or explosion, or the production of a flammable, toxic, or poisonous gas, or the deterioration of the primary or secondary containment shall be submitted. (6) Monitoring program. A description of the location, type, manufacturer specifications (if applicable), and suitability of monitoring methods to be used in each storage facility storing hazardous materials which are liquids, solids or gases at STP shall be submitted. It shall also specify the frequency of inspections of storage facilities which will be conducted by the permittee. (7) Record keeping forms. An inspection check sheet or log designed to be used in conjunction with routine inspections shall be submitted. The check sheet or log shall provide for the recording of the date and time of inspection and, for monitoring activity, the date and time of any corrective action taken, the name of the inspector, and the countersignature of the designated safety manager for the facility or the responsible official as designated in the HMMP. (8) Emergency equipment. A description of the emergency equipment availability, testing, and maintenance shall be submitted. (9) Variation in information. The environmental services department may require additional information for the HMMP where such information is reasonably necessary to meet the intent of this article. (e) HMMP alternative. Whenever permittee has submitted a plan which includes substantially the same information as is required for any component(s) of the HMMP to any other public agency regulating hazardous materials, such plan may be submitted to the hazardous materials management permit office in lieu of such components. The environmental services department may give deference to any approval of such plan by the other public agency.

(Ord. No. 97-332, § 1, 1-5-98; Ord. No. 2002-O-287, § 1, 11-4-02)

Ask a question about Laredo law

Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.