APPENDIX N - NOISE ATTENUATION PERFORMANCE STANDARDS FOR STRUCTURES LOCATED WITHIN AIRPORT NOISE SPECIFIC USE ZONING OVERLAY DISTRICTS
N101 SCOPE The performance standards in this chapter are intended to provide for the insulation of the interior of buildings to an Ldn 45 or less from outside noise levels over Ldn 65. The standards shall be applied to construction of new noise-sensitive uses approved within districts and subdistricts where noise levels are expected to exceed 65 Ldn, and for reconstruction, remodeling, or additions to existing buildings of the types mentioned above when the value of the improvement exceeds 50 percent of the value of the existing structures. Where noise-sensitive activities are carried on in only a portion of new or reconstructed commercial buildings, only those areas judged noise-sensitive need to be protected. The provisions of this section control in the event of a conflict with other provisions of this code. N102 DEFINITIONS The special terms used in these provisions are defined as follows: Day-night average sound level (Ldn) - shall mean the estimated cumulative aircraft or other noise exposure in decibels of noise as measured by an A-weighed sound-level meter. In the Ldn procedure, noise exposures are accumulated for a typical 24 - hour period. A weighing factor equivalent to a penalty of 10 decibels is applied to aircraft operations or other noise sources between 10:00 p.m. and 7:00 a.m. to account for the increased sensitivity of people to night-time noise. The Ldn values in effect in the City of Laredo are those expressed graphically by contour lines approved by the Council. Decibel (db) - shall mean a unit of measure of a sound expressed from a calibrated sound-level meter using an A-level weighting scale. Interior noise level - Sound level of noise in any habitable room with windows and doors closed. Noise - shall mean aircraft or other noise that interferes with speech and hearing, or is intense enough to damage hearing, or is otherwise annoying. Noise control areas - shall mean those areas officially adopted in the Airport Noise Specific Use Zoning Overlay District (AN) designated to be within a Ldn 65 noise area or greater. N103 STRUCTURES REQUIRING PROTECTION Structures to be protected shall include, but are not limited to existing residential structures and the portion of non-residential structures in which noise - sensitive activities are conducted (e.g., research facilities, hotel sleeping rooms, meeting rooms, and similar activities). N104 REQUIREMENTS FOR NOISE LEVELS OVER 65 LDN All structures regulated under this chapter in noise-level area Ldn 65 shall meet the following criteria: I. General. 1. Brick veneer, masonry blocks, or stucco exterior walls shall be constructed airtight. All joints shall be grouted or caulked airtight. 2. At the penetration of exterior walls by pipes, ducts, or conduits, the space between the wall and pipes, ducts, or conduits shall be caulked or filled with mortar. 3. Window and/or through-the-wall HVAC type units shall not be used. 4. Operational, vented fireplaces shall not be used. 5. All sleeping spaces shall be provided with a sound-absorbing ceiling and carpeted floor. 6. Through-the-wall/door mailboxes shall not be used. II. MINIMUM NOISE REDUCTION OF 25 db. A. Exterior Walls. 1. Masonry walls having a surface weight of at least 40 pounds per square foot do not require a furred interior wall. In areas over 70 Ldn, masonry walls having a surface weight of at least 75 pounds per square foot do not require a furred interior wall. At least one surface of concrete block wall shall be plastered or painted with heavy "bridging" paint. 2. Stud walls shall be at least four (4) inches in nominal depth and shall be finished on the outside with siding on sheathing, stucco, or brick veneer. a. Interior surface of the exterior stud walls shall be of gypsum board or plaster at least ½-inch thick, installed on the studs. The gypsum board or plaster may be fastened rigidly to the studs if the exterior is brick veneer or stucco. If the exterior is siding-on-sheathing, the interior gypsum board or plaster must be fastened resiliently to the studs. b. Continuous composition board, plywood, or gypsum board sheathing shall cover the exterior side of the wall studs behind wood or metal siding. The sheathing and facing shall weigh at least four (4) pounds per square foot. c. All edges of the sheathing shall be sealed with resilient caulking. d. Insulation material with a minimum thermal resistance factor (R) of 11 which is at least two (2) inches thick shall be installed continuously throughout the cavity space behind the exterior sheathing and between wall studs. Insulation shall be glass fiber or mineral wool. B. Window. 1. Glass of double-glazed windows shall be used and at least 3/16 inch thick. 2. Double-glazed windows shall employ fixed sash or efficiently weather-stripped operable sash. The sash shall be rigid and weather-stripped with material that is compressed airtight when the window is closed. 3. Glass of fixed-sash windows shall be sealed in an airtight manner with a non-hardening sealant, or a soft elastomeric gasket or glazing tape. 4. The perimeter of the window frame shall be sealed airtight to the exterior wall construction with a resilient sealant. 5. The total area of glass of both windows and exterior doors in sleeping spaces shall not exceed twenty percent (20%) of the floor area. C. Doors. 1. All exterior side-hinged doors shall be solid-core wood or insulated or hollow metal at least 1.75 inches thick and shall be fully weather-stripped. 2. The glass of double-glazed sliding doors shall be at least 3/16 of an inch thick and separated by a minimum ½-inch airspace with a laboratory sound transmission rating of STC-28 or greater. The frame shall be provided with an efficiently airtight weather-stripping material. 3. The perimeter of door frames shall be sealed airtight to the exterior wall construction. 4. Glass in doors shall be set and sealed in an airtight non-hardening sealant, or a soft elastomeric gasket or glazing tape. D. Roof. 1. With an attic or rafter space at least six inches deep, and with a ceiling below, the roof shall consist of ½-inch composition board, plywood, or gypsum board sheathing topped by roofing as required. 2. If the underside of the roof is exposed, or if the attic or rafter space is less than six (6) inches, the roof construction shall have a surface weight of at least six (6) pounds per square foot, except that, in areas over 70 Ldn, the roof construction shall have a surface weight of at least nine (9) pounds per square foot. Rafters, joists, or other framing may not be included in the surface weight calculation. 3. Window or dome skylights shall be double glazed and separately by minimum ½-inch airspace. In areas over 70 Ldn, skylights are not permitted. E. Ceilings. 1. Gypsum board of plaster ceilings at least ½-inch thick shall be provided below attic space or roof rafters or roof construction less than eight (8) pounds per square foot (psf). Ceilings shall be substantially airtight, with minimum number of penetrations. 2. Glass fiber or mineral wood insulation at least six (6) inches thick with a thermal resistance (R) factor of not less than nineteen shall be provided above the ceiling between joists. Insulation in the attic space shall have no paper or foil covering on the face exposed to the attic. F. Floors. The floor of the lowest occupied rooms shall be slab on grade, below grade, or over a fully enclosed basement. All door and window openings in the fully enclosed basement shall be tightly fitted. All sleeping rooms shall be provided with carpeting or an acoustical ceiling. G. Ventilation. 1. A mechanical ventilation system shall be installed that will provide the minimum air circulation and fresh air-supply requirements for various uses in occupied rooms, without need to open any windows, doors, or other openings to the exterior. Window and wall ventilating units shall not be used. 2. Gravity vent openings in the attic shall not exceed code minimum in number and size. The openings shall be fitted with transfer ducts at least three feet in length, containing approved internal sound-absorbing duct lining. Each duct shall have a line 90-degree bend in the duct such that there is not direct line of sight from the exterior through the duct into the attic. 3. If a fan is used for forced ventilation, the attic inlet and discharge openings shall be fitted with sheet metal transfer ducts of at least 20-gauge steel, which shall be lined with one-inch thick approved duct liner, and shall be at least five (5) feet long with one 90-degree bend. In areas over 70 Ldn, the duct lining shall be at least ten (10) feet long. 4. All vent ducts connecting the interior space to the outdoors, excepting domestic range and dryer exhaust ducts, shall contain at last a 10-foot length of approved internal sound-absorbing duct lining. Each duct shall be provided with a line 90-degree bend in the duct such that there is no direct line of sight through the duct. 5. Duct lining shall be a coated glass fiber duct liner at least one-inch thick, approved and suitable for the intended use. 6. Domestic range and dryer exhaust ducts connecting the interior space to the outdoors shall contain a baffle plate across the exterior termination that allows proper ventilation. The dimensions of the baffle plate should extend at least one diameter beyond the line of sight into the vent duct. The baffle plate shall be of the same material and thickness as the vent duct material and shall have the same free area as the vent duct. 7. Building heating units with flues or combustion air vents shall be located in a closet or room closed off from the occupied space by doors. 8. Doors between occupied space and mechanical equipment areas shall be solid-core wood or 20-gauge steel hollow metal at least 1.75 inches thick and shall be fully weather-stripped. III. MINIMUM NOISE REDUCTION OF 30 db. A. Exterior Walls. 1. Masonry walls having a surface weight of at least forty (40) pounds per square foot do not require a furred interior wall. In areas over 70 Ldn, masonry walls having a surface weight of at least seventy-five (75) pounds per square foot do not require a furred interior wall. At least one surface of concrete block wall shall be plastered or painted with heavy "bridging" paint. 2. Stud walls shall be at least four (4) inches in nominal depth and shall be finished on the outside with siding on sheathing, stucco, or brick veneer. a. Interior surface of the exterior stud walls shall be of gypsum board or plaster at least ⅝-inch thick, installed on the studs. The gypsum board or plaster may be fastened rigidly to the studs if the exterior is brick veneer or stucco. If the exterior is siding-on-sheathing, the interior gypsum board or plaster must be fastened resiliently to the studs. b. Continuous composition board, plywood, or gypsum board sheathing of not less than ½ inch in thickness shall cover the exterior side of the wall studs behind wood or metal siding. The sheathing and facing shall weigh at least four pounds per square foot. c. All edges of the sheathing shall be sealed with resilient caulking. d. Insulation material with a minimum thermal resistance factor (R) of 11 which is at least two (2) inches thick shall be installed continuously throughout the cavity space behind the exterior sheathing and between wall studs. Insulation shall be glass fiber or mineral wool. B. Window. 1. Double-glazed windows shall be used and shall be not less than 3/16 inch in thickness. Panes of glass shall be separated by an air-space of not less than three inches, and shall be of unequal thickness. 2. Double-glazed windows shall employ fixed sash or efficiently weather-stripped operable sash. The sash shall be rigid and weather-stripped with material that is compressed airtight when the window is closed. 3. Glass of fixed-sash windows shall be sealed in an airtight manner with a non-hardening sealant, or a soft elastomeric gasket or glazing tape. 4. The perimeter of the window frame shall be sealed airtight to the exterior wall construction with a resilient sealant. 5. The total area of glass of both windows and exterior doors in sleeping spaces shall not exceed twenty percent (20%) of the floor area. C. Doors. 1. All exterior side-hinged doors shall be solid-core wood or insulated or hollow metal at least 1.75 inches thick and shall be fully weather-stripped. 2. The glass of double-glazed sliding doors shall be at least 3/16 of an inch thick and separated by a minimum four-inch airspace with a laboratory sound transmission rating of STC-28 or greater. The frame shall be provided with an efficiently airtight weather-stripping material. Single frame sliding glass doors are prohibited. 3. The perimeter of door frames shall be sealed airtight to the exterior wall construction. 4. Glass in doors shall be set and sealed in an airtight non-hardening sealant, or a soft elastomeric gasket or glazing tape. D. Roof. 1. With an attic or rafter space at least six (6) inches deep, and with a ceiling below, the roof shall consist of ¾-inch continuous plywood sheathing topped by roofing as required. Exposed roof decks shall not be less than two (2) inches of wood or concrete. 2. If the underside of the roof is exposed, or if the attic or rafter space is less than six (6) inches, the roof construction shall have a surface weight of not less than twelve (12) pounds per square foot. Rafters, joists, or other framing may not be included in the surface weight calculation. 3. Window or dome skylights shall be double glazed and separately by minimum ½-inch airspace. In areas over 70 Ldn, skylights are not permitted. E. Ceilings. 1. Gypsum board of plaster ceilings at least ½-inch thick shall be provided below attic space or roof rafters or roof construction of less than two (2) inches in thickness and weighing less than twelve (12) pounds per square foot (psf). 2. The ceiling shall be not less than twelve (12) inches below the roof sheathing and substantially airtight, with a minimum number of penetrations. 3. Glass fiber or mineral wood insulation at least six (6) inches thick with a thermal resistance (R) factor of not less than nineteen shall be provided above the ceiling between joists. Insulation in the attic space shall have no paper or foil covering on the face exposed to the attic. F. Floors. The floor of the lowest occupied rooms shall be slab on grade, below grade, or over a fully enclosed basement. All door and window openings in the fully enclosed basement shall be tightly fitted. All sleeping rooms shall be provided with carpeting or an acoustical ceiling. G. Ventilation. 1. A mechanical ventilation system shall be installed that will provide the minimum air circulation and fresh air-supply requirements for various uses in occupied rooms, without need to open any windows, doors, or other openings to the exterior. Window and wall ventilating units shall not be used. 2. Gravity vent openings in the attic shall not exceed code minimum in number and size. The openings shall be fitted with transfer ducts at least five (5) feet in length, containing approved internal sound-absorbing duct lining. Each duct shall have a line 90-degree bend in the duct such that there is not direct line of sight from the exterior through the duct into the attic. 3. If a fan is used for forced ventilation, the attic inlet and discharge openings shall be fitted with sheet metal transfer ducts of at least 20-gauge steel, which shall be lined with one-inch thick approved duct liner, and shall be at least five (5) feet long with one 90-degree bend. In areas over 70 Ldn, the duct lining shall be at least ten (10) feet long. 4. All vent ducts connecting the interior space to the outdoors, excepting domestic range and dryer exhaust ducts, shall contain at last a ten-foot length of approved internal sound-absorbing duct lining. Each duct shall be provided with a line 90-degree bend in the duct such that there is no direct line of sight through the duct. 5. Duct lining shall be a coated glass fiber duct liner at least one-inch thick, approved and suitable for the intended use. 6. Domestic range and dryer exhaust ducts connecting the interior space to the outdoors shall contain a baffle plate across the exterior termination that allows proper ventilation. The dimensions of the baffle plate should extend at least one diameter beyond the line of sight into the vent duct. The baffle plate shall be of the same material and thickness as the vent duct material and shall have the same free area as the vent duct. 7. Building heating units with flues or combustion air vents shall be located in a closet or room closed off from the occupied space by doors. 8. Doors between occupied space and mechanical equipment areas shall be solid-core wood or 20-gauge steel hollow metal at least 1.75 inches thick and shall be fully weather-stripped.
Ask a question about Laredo law
Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.